SearcharxivSearch

arXiv subjects

P. Gill

Publications and source records attributed to P. Gill.

At least 19 recordsLinked to original sources

Measuring the stability of fundamental constants with a network of clocks

The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the goal of the recently launched QSNET project: A network of clocks for measuring the stability of fundamental constants. QSNET will include state-of-the-art atomic clocks, but will also develop next-generation molecular and highly charged ion clocks with enhanced sensitivity to variations of fundamental constants. We describe the technological and scientific aims of QSNET and evaluate its expected performance. We show that in the range of parameters probed by QSNET, either we will discover new physics, or we will impose new constraints on violations of fundamental symmetries and a range of theories beyond the Standard Model, including dark matter and dark energy models.

hep-ph

Direct comparisons of European primary and secondary frequency standards via satellite techniques

We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.

physics.ins-det

SAGE: A Proposal for a Space Atomic Gravity Explorer

The proposed mission "Space Atomic Gravity Explorer" (SAGE) has the scientific objective to investigate gravitational waves, dark matter, and other fundamental aspects of gravity as well as the connection between gravitational physics and quantum physics using new quantum sensors, namely, optical atomic clocks and atom interferometers based on ultracold strontium atoms.

astro-ph.IM

Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks

We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.

astro-ph.CO

Compact laser system for a laser-cooled ytterbium ion microwave frequency standard

The development of a transportable microwave frequency standard based on the ground-state transition of $^{171}\mathrm{Yb^{+}}$ at ~12.6 GHz requires a compact laser system for cooling the ions, clearing out of long-lived states and also for photoionisation. In this paper, we describe the development of a suitable compact laser system based on a 6U height rack-mounted arrangement with overall dimensions $260 \times 194 \times 335$ mm. Laser outputs at 369 nm (for cooling), 399 nm (photoionisation), 935 nm (repumping) and 760 nm (state clearout) are combined in a fiber arrangement for delivery to our linear ion trap and we demonstrate this system by cooling of $^{171}\mathrm{Yb^{+}}$ ions. Additionally, we demonstrate that the lasers at 935 nm and 760 nm are close in frequency to water vapor and oxygen absorption lines respectively; specifically, at 760 nm, we show that one $^{171}\mathrm{Yb^{+}}$ transition is within the pressure broadened profile of an oxygen line. These molecular transitions form convenient wavelength references for the stabilization of lasers for a $^{171}\mathrm{Yb^{+}}$ frequency standard.

physics.atom-ph

Laser-cooled ytterbium ion frequency standard

We report on the development of a trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit ($51\times49\times28$ cm) and comprises laser, electronics, and physics package subsystems. The performance of this development system is evaluated; the fractional frequency instability was measured to be $3.6\times10^{-12}/\surd\tau$ for averaging times between 30 s and 1500 s.

physics.atom-ph

Test of special relativity using a fiber network of optical clocks

Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson--Mansouri--Sexl parameter $|α|\lesssim 1.1 \times10^{-8}$ quantifying a violation of time dilation, thus improving by a factor of around two the best known constraint obtained with Ives--Stilwell type experiments, and by two orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this paper will improve by orders of magnitude in the near future.

gr-qc

A High-Performance, Low-Cost Laser Shutter using a Piezoelectric Cantilever Actuator

We report the design and characterization of an optical shutter based on a piezoelectric cantilever. Compared to conventional electro-magnetic shutters, the device is intrinsically low power and acoustically quiet. The cantilever position is controlled by a high-voltage op-amp circuit for easy tuning of the range of travel, and mechanical slew rate, which enables a factor of 30 reduction in mechanical noise compared to a rapidly switched device. We achieve shuttering rise and fall times of 11 $μ$s, corresponding to mechanical slew rates of 1.3 $\textrm{ ms}^{-1}$, with an timing jitter of less than 1 $μ$s. When used to create optical pulses, we achieve minimum pulse durations of 250 $μ$s. The reliability of the shutter was investigated by operating continuously for one week at 10 Hz switching rate. After this period, neither the shutter delay or actuation speed had changed by a notable amount. We also show that the high-voltage electronics can be easily configured as a versatile low-noise, high-bandwidth piezo driver, well-suited to applications in laser frequency control.

physics.ins-det

Development of a strontium optical lattice clock for the SOC mission on the ISS

The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability below $1 \times 10^{-15} τ^{-1/2}$ and fractional inaccuracy $5 \times 10^{-17}$. For the design of the clock, techniques and approaches suitable for later space application are used, such as modular design, diode lasers, low power consumption subunits, and compact dimensions. The Sr clock apparatus is fully operational, and the clock transition in $^{88}$Sr was observed with linewidth as small as 9 Hz.

physics.atom-ph

Modified hyper-Ramsey methods for the elimination of probe shifts in optical clocks

We develop a method of modified hyper-Ramsey spectroscopy in optical clocks, achieving complete immunity to the frequency shifts induced by the probing fields themselves. Using particular pulse sequences with tailored phases, frequencies, and durations, we can derive an error signal centered exactly at the unperturbed atomic resonance with a steep discriminant which is robust against variations in the probe shift. We experimentally investigate the scheme using the magnetically-induced $^1$S$_0- ^3$P$_0$ transition in $^{88}$Sr, demonstrating automatic suppression of a sizeable \num{2e-13} probe Stark shift to below \num{1e-16} even with very large errors in shift compensation.

physics.atom-ph

A Single-Ion Trap with Minimized Ion-Environment Interactions

We present a new single-ion endcap trap for high precision spectroscopy that has been designed to minimize ion-environment interactions. We describe the design in detail and then characterize the working trap using a single trapped 171 Yb ion. Excess micromotion has been eliminated to the resolution of the detection method and the trap exhibits an anomalous phonon heating rate of d /dt = 24 +30/-24 per second. The thermal properties of the trap structure have also been measured with an effective temperature rise at the ion's position of 0.14 +/- 0.14 K. The small perturbations to the ion caused by this trap make it suitable to be used for an optical frequency standard with fractional uncertainties below the 10^-18 level.

physics.atom-ph

Frequency comparison of ${}^{171}$Yb${}^+$ ion optical clocks at PTB and NPL via GPS PPP

We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the ${{}^2S_{1/2}(F=0)-{}^2D_{3/2}(F=2)}$ electric quadrupole transition in ${}^{171}$Yb${}^+$ via an optical femtosecond frequency comb. To profit from long coherent GPS link measurements we extrapolate over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS link. We determined the total statistical uncertainty consisting of the GPS link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference $y(\mathrm{PTB})-y(\mathrm{NPL})$ of $-1.3(1.2)\times 10^{-15}$ for a total measurement time of 67 h. This result is consistent with an agreement of both optical clocks and with recent absolute frequency measurements against caesium fountain clocks.

physics.atom-ph

Least-squares analysis of clock frequency comparison data to deduce optimized frequency and frequency ratio values

A method is presented for analysing over-determined sets of clock frequency comparison data involving standards based on a number of different reference transitions. This least-squares adjustment procedure, which is based on the method used by CODATA to derive a self-consistent set of values for the fundamental physical constants, can be used to derive optimized values for the frequency ratios of all possible pairs of reference transitions. It is demonstrated to reproduce the frequency values recommended by the International Committee for Weights and Measures, when using the same input data used to derive those values. The effects of including more recently published data in the evaluation is discussed and the importance of accounting for correlations between the input data is emphasised.

physics.data-an

Development of a strontium optical lattice clock for the SOC mission on the ISS

Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project no. 263500, during the years 2011-2015 a compact, modular and robust strontium lattice optical clock demonstrator has been developed. Goal performance is a fractional frequency instability below 1x10^{-15}, tau^{-1/2} and a fractional inaccuracy below 5x10^{-17}. Here we describe the current status of the apparatus' development, including the laser subsystems. Robust preparation of cold {88}^Sr atoms in a second stage magneto-optical trap (MOT) is achieved.

physics.atom-ph

Frequency ratio of two optical clock transitions in $^{171}$Yb$^+$ and constraints on the time-variation of fundamental constants

Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171Yb+. The absolute frequencies of both transitions are also presented, each with a relative standard uncertainty of $6\times 10^{-16}$. Combining our results with those from other experiments, we report a three-fold improvement in the constraint on the time-variation of the proton-to-electron mass ratio, $\dotμ/μ = 0.2(1.1)\times 10^{-16}$ year$^{-1}$, along with an improved constraint on time-variation of the fine structure constant, $\dotα/α = -0.7(2.1)\times 10^{-17}$ year$^{-1}$.

physics.atom-ph

Evaluating the performance of the NPL femtosecond frequency combs: Agreement at the $10^{-21}$ level

Results are presented from a series of comparisons between two independent femtosecond frequency comb systems at NPL, which were carried out in order to assess their systematic uncertainty. Simultaneous measurements with the two systems demonstrate agreement at the level of 5 x $10^{-18}$ when measuring an optical frequency against a common microwave reference. When simultaneously measuring the ratio of two optical frequencies, agreement at the 3 x $10^{-21}$ level is observed. The results represent the highest reported level of agreement to date between Ti:sapphire and Er-doped femtosecond combs. The limitations of the combs when operating in these two different manners are discussed, including traceability to the SI second, which can be achieved with an uncertainty below 1 x $10^{-16}$. The technical details presented underpin recent absolute frequency measurements of the $^{88}$Sr$^+$ and $^{171}$Yb$^+$ optical clock transitions at NPL, as well as a frequency ratio measurement between the two optical clock transitions in $^{171}$Yb$^+$.

physics.optics

Optical atomic clocks

In the last ten years extraordinary results in time and frequency metrology have been demonstrated. Frequency-stabilization techniques for continuous-wave lasers and femto-second optical frequency combs have enabled a rapid development of frequency standards based on optical transitions in ultra-cold neutral atoms and trapped ions. As a result, today's best performing atomic clocks tick at an optical rate and allow scientists to perform high-resolution measurements with a precision approaching a few parts in $10^{18}$. This paper reviews the history and the state of the art in optical-clock research and addresses the implementation of optical clocks in a possible future redefinition of the SI second as well as in tests of fundamental physics.

physics.atom-ph

The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems

The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.

quant-ph