Searcharxiv⌕ Search

arXiv subjects

P. K. Grimes

Publications and source records attributed to P. K. Grimes.

25 records · Page 2Linked to original sources

Thermal Testing for Cryogenic CMB Instrument Optical Design

Observations of the Cosmic Microwave Background rely on cryogenic instrumentation with cold detectors, readout, and optics providing the low noise performance and instrumental stability required to make more sensitive measurements. It is therefore critical to optimize all aspects of the cryogenic design to achieve the necessary performance, with low temperature components and acceptable system cooling requirements. In particular, we will focus on our use of thermal filters and cold optics, which reduce the thermal load passed along to the cryogenic stages. To test their performance, we have made a series of in situ measurements while integrating the third receiver for the BICEP Array telescope. In addition to characterizing the behavior of this receiver, these measurements continue to refine the models that are being used to inform design choices being made for future instruments.

astro-ph.IM↗

Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.

astro-ph.IM↗

2022 Upgrade and Improved Low Frequency Camera Sensitivity for CMB Observation at the South Pole

Constraining the Galactic foregrounds with multi-frequency Cosmic Microwave Background (CMB) observations is an essential step towards ultimately reaching the sensitivity to measure primordial gravitational waves (PGWs), the sign of inflation after the Big-Bang that would be imprinted on the CMB. The BICEP Array telescope is a set of multi-frequency cameras designed to constrain the energy scale of inflation through CMB B-mode searches while also controlling the polarized galactic foregrounds. The lowest frequency BICEP Array receiver (BA1) has been observing from the South Pole since 2020 and provides 30 GHz and 40 GHz data to characterize the Galactic synchrotron in our CMB maps. In this paper, we present the design of the BA1 detectors and the full optical characterization of the camera including the on-sky performance at the South Pole. The paper also introduces the design challenges during the first observing season including the effect of out-of-band photons on detectors performance. It also describes the tests done to diagnose that effect and the new upgrade to minimize these photons, as well as installing more dichroic detectors during the 2022 deployment season to improve the BA1 sensitivity. We finally report background noise measurements of the detectors with the goal of having photon noise dominated detectors in both optical channels. BA1 achieves an improvement in mapping speed compared to the previous deployment season.

astro-ph.IM↗

Waveguide-to-planar circuit transition for millimetre-wave detectors

We present a novel design of a waveguide to microstrip or coplanar waveguide transition using a unilateral finline taper. The transition from the unilateral finline mode to the TEM microstrip mode is done directly, avoiding the antipodal finline tapers that have commonly been employed. This results in significant simplification of the design and fabrication, and shortening of the chip length, thereby reducing insertion loss. In this paper we shall present designs at 90 GHz that can be employed in superconducting tunnel junction mixers or Transition Edge Sensor bolometers, and scale-model measurements at 15 GHz.

astro-ph↗

Detecting the B-mode Polarisation of the CMB with Clover

We describe the objectives, design and predicted performance of Clover, which is a ground-based experiment to measure the faint ``B-mode'' polarisation pattern in the cosmic microwave background (CMB). To achieve this goal, clover will make polarimetric observations of approximately 1000 deg^2 of the sky in spectral bands centred on 97, 150 and 225 GHz. The observations will be made with a two-mirror compact range antenna fed by profiled corrugated horns. The telescope beam sizes for each band are 7.5, 5.5 and 5.5 arcmin, respectively. The polarisation of the sky will be measured with a rotating half-wave plate and stationary analyser, which will be an orthomode transducer. The sky coverage combined with the angular resolution will allow us to measure the angular power spectra between 20 < l < 1000. Each frequency band will employ 192 single polarisation, photon noise limited TES bolometers cooled to 100 mK. The background-limited sensitivity of these detector arrays will allow us to constrain the tensor-to-scalar ratio to 0.026 at 3sigma, assuming any polarised foreground signals can be subtracted with minimal degradation to the 150 GHz sensitivity. Systematic errors will be mitigated by modulating the polarisation of the sky signals with the rotating half-wave plate, fast azimuth scans and periodic telescope rotations about its boresight. The three spectral bands will be divided into two separate but nearly identical instruments - one for 97 GHz and another for 150 and 225 GHz. The two instruments will be sited on identical three-axis mounts in the Atacama Desert in Chile near Pampa la Bola. Observations are expected to begin in late 2009.

astro-ph↗

Compact broadband planar orthomode transducer

We present the design and test results of a compact C-band orthomode transducer which comprises four rectangular probes orthogonally arranged in a circular waveguide, designed to work in the WG13 band. Measurements of the system in the frequency range 4.64 GHz to 7.05 GHz agree very well with simulation results and show a cross-polarisation level below -58 dB, a return loss of about -20 dB, and an insertion loss difference of less than 0.18 dB between the orthogonal polarisation modes across the full waveguide band.

astro-ph↗

Novel Josephson Junction Geometries in NbCu bilayers fabricated by Focused Ion Beam Microscope

We explore novel junction configurations as an extension of our established Focused Ion Beam-based low TC SNS Junction fabrication technique. By milling a circular trench (diameter 1 micron, width 50 nm) in a 125 nm Nb 75 nm Cu bilayer we define a superconducting island connected to the bulk of the film by a normal metal barrier and entirely enclosed in-plane by the superconducting film. The circular junction properties can be probed by depositing an insulating layer over the device and drilling a 0.3 micron diameter hole down to the island to allow a Nb via to be deposited. Device behavior has been studied at 4.2 K. An SNS-like current voltage characteristic and Shapiro steps are observed. It is in terms of magnetic field behavior that the device exhibits novel characteristics: as the device is entirely enclosed in type II superconductor, when a magnetic field is applied perpendicular to the plane of the film, only quantized flux can enter the junction. Hence as applied magnetic field is increased the junction critical current is unchanged, then abruptly suppressed as soon as a flux quantum enters (close to the expected value of lower critical field for the film).

cond-mat.supr-con↗