Searcharxiv⌕ Search

arXiv subjects

P. Knights

Publications and source records attributed to P. Knights.

33 records · Page 2Linked to original sources

Fast Neutron Spectroscopy with a High-pressure Nitrogen-filled Large Volume Spherical Proportional Counter

We present a fast neutron spectroscopy system based on a nitrogen-filled, large volume gaseous detector, the Spherical Proportional Counter. The system has been successfully operated up to gas pressure of 1.5 bar. Neutron energy is estimated through measurement of the 14N(n,a)11B and 14N(n,p)14C reaction products. These reactions have comparable cross sections and Q-values with the 3He(n,p)3H reaction making nitrogen a good alternative to 3He use for fast neutron detection. Two detectors were built at the University of Birmingham and are currently used for the measurement of fast and thermal neutrons in the University of Birmingham and the Boulby underground laboratory, respectively.

hep-ex↗

Neutron spectroscopy: The case of the spherical proportional counter

Neutron spectroscopy is an invaluable tool for many scientific and industrial applications, including underground Dark Matter searches. Neutron-induced backgrounds produced by cosmic ray muons and the cavern radioactivity can mimic the expected Dark Matter signal. However, existing neutron detection methods have several drawbacks and limitations, thus measurements remain elusive. A promising new approach to neutron spectroscopy is the use of a nitrogen-filled spherical proportional counter that exploits the $^{14}$N(n,$α$)$^{11}$B and $^{14}$N(n, p)$^{14}$C reactions. This is a safe, inexpensive, effective and reliable technique. In this work, the latest instrumentation developments are incorporated in a compact detector operated at the University of Birmingham (UoB) with high gain at gas pressure up to 1.8\,bar. We demonstrate spectroscopic measurements of thermalised and fast neutrons respectively from an $^{241}$Am-$^9$Be source and from the MC40 cyclotron facility at UoB. Additionally, the detector response to neutrons is simulated using a framework developed at UoB and compared with the experimental results.

physics.ins-det↗

Measurements of the ionization efficiency of protons in methane

The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $\mathrm{IQF}~(E_K)= E_K^α~/~(β+ E_K^α)$ with $α=0.70\pm0.08$ and $β= 1.32\pm0.17$. In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $33\%$ at $2~\mathrm{keV}$

physics.ins-det↗

Simultaneous scintillation light and charge readout of a pure argon filled Spherical Proportional Counter

The possible use of a Spherical Proportional Counter for the search of neutrinoless double beta decay is investigated in the R2D2 R&D project. Dual charge and scintillation light readout may improve the detector performance. Tests were carried out with pure argon at 1.1 bar using a 6x6 mm2 silicon photomultiplier. Scintillation light was used for the first time to trigger in a spherical proportional counter. The measured drift time is in excellent agreement with the expectations from simulations. Furthermore the light signal emitted during the avalanche development exhibits features that could be exploited for event characterisation.

physics.ins-det↗

Solar Kaluza-Klein axion search with NEWS-G

Kaluza-Klein (KK) axions appear in theories with extra dimensions as higher mass, significantly shorter lifetime, excitations of the Peccei-Quinn axion. When produced in the Sun, they would remain gravitationally trapped in the solar system, and their decay to a pair of photons could provide an explanation of the solar corona heating problem. A low-density detector would discriminate such a signal from the background, by identifying the separation of the interaction point of the two photons. The NEWS-G collaboration uses large volume Spherical Proportional Counters, gas-filled metallic spheres with a spherical anode in their centre. After observation of a single axionlike event in a 42 day long run with the SEDINE detector, a $90\%$ C.L. upper limit of $g_{aγγ}<8.99\cdot10^{-13}\,GeV^{-1}$ is set on the axion-photon coupling for a KK axion density on Earth of $n_{a}=4.07\cdot10^{13}\,m^{-3}$ and two extra dimensions of size $R = 1\,eV^{-1}$.

hep-ex↗

Quenching factor measurements of neon nuclei in neon gas

The NEWS-G collaboration uses Spherical Proportional Counters (SPCs) to search for weakly interacting massive particles (WIMPs). In this paper, we report the first measurements of the nuclear quenching factor in neon gas at \SI{2}{bar} using an SPC deployed in a neutron beam at the TUNL facility. The energy-dependence of the nuclear quenching factor is modelled using a simple power law: $α$E$_{nr}^β$; we determine its parameters by simultaneously fitting the data collected with the detector over a range of energies. We measured the following parameters in Ne:CH$_{4}$ at \SI{2}{bar}: $α$ = 0.2801 $\pm$ 0.0050 (fit) $\pm$ 0.0045 (sys) and $β$ = 0.0867 $\pm$ 0.020 (fit) $\pm$ 0.006(sys). Our measurements do not agree with expected values from SRIM or Lindhard theory. We demonstrated the feasibility of performing quenching factor measurements at sub-keV energies in gases using SPCs and a neutron beam.

physics.ins-det↗

Neutron spectroscopy with N$_2$-filled high-pressure large-volume spherical proportional counters

Precise in-situ measurements of the neutron flux in underground laboratories is crucial for direct dark matter searches, as neutron induced backgrounds can mimic the typical dark matter signal. The development of a novel neutron spectroscopy technique using Spherical Proportional Counters is investigated. The detector is operated with nitrogen and is sensitive to both fast and thermal neutrons through the $^{14}$N(n, $α$)$^{11}$B and $^{14}$N(n, p)$^{14}$C reactions. This method holds potential to be a safe, inexpensive, effective, and reliable alternative to $^3$He-based detectors. Measurements of fast and thermal neutrons from an Am-Be source with a Spherical Proportional Counter operated at pressures up to 2 bar at Birmingham are discussed.

physics.ins-det↗

R2D2 spherical TPC: first energy resolution results

Spherical time projection chambers (TPC), also known as spherical proportional counters, are employed in the search for rare phenomena, such as light Dark Matter candidates. The spherical TPC exhibits a number of essential features, making it a promising candidate for the search of neutrinoless double beta decay ($β\beta0ν$). A tonne-scale spherical TPC experiment could cover a region of parameter space relevant for the inverted mass hierarchy with a few years of data taking. In this direction, the major R\&D goal of the R2D2 effort is the demonstration of the required energy resolution. First results from an argon-filled prototype detector are reported, demonstrating an energy resolution of 1.1\% FWHM for 5.3~MeV $α$ tracks in the 0.2 to 1.1~bar pressure range. This is a major milestone in terms of energy resolution, paving the way for further studies with xenon gas, and the possible use of this technology for $β\beta0ν$ searches.

physics.ins-det↗

Copper electroplating for background suppression in the NEWS-G experiment

New Experiments with Spheres-Gas (NEWS-G) is a dark matter direct detection experiment that will operate at SNOLAB (Canada). Similar to other rare-event searches, the materials used in the detector construction are subject to stringent radiopurity requirements. The detector features a 140-cm diameter proportional counter comprising two hemispheres made from commercially sourced 99.99% pure copper. Such copper is widely used in rare-event searches because it is readily available, there are no long-lived Cu radioisotopes, and levels of non-Cu radiocontaminants are generally low. However, measurements performed with a dedicated 210Po alpha counting method using an XIA detector confirmed a problematic concentration of 210Pb in bulk of the copper. To shield the proportional counter's active volume, a low-background electroforming method was adapted to the hemispherical shape to grow a 500-$μ$m thick layer of ultra-radiopure copper to the detector's inner surface. In this paper the process is described, which was prototyped at Pacific Northwest National Laboratory (PNNL), USA, and then conducted at full scale in the Laboratoire Souterrain de Modane in France. The radiopurity of the electroplated copper was assessed through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Measurements of samples from the first (second) hemisphere give 68% confidence upper limits of <0.58 $μ$Bq/kg (<0.24 $μ$Bq/kg) and <0.26 $μ$Bq/kg (<0.11 $μ$Bq/kg) on the 232Th and 238U contamination levels, respectively. These results are comparable to previously reported measurements of electroformed copper produced for other rare-event searches, which were also found to have low concentration of 210Pb consistent with the background goals of the NEWS-G experiment.

physics.ins-det↗

A resistive ACHINOS multi-anode structure with DLC coating for spherical proportional counters

The spherical proportional counter is a gaseous detector used in a variety of applications, including direct dark matter and neutrino-less double beta decay searches. The ACHINOS multianode structure is a read-out technology that overcomes the limitations of single-anode read-out structures for large-size detectors and operation under high pressure. A resistive ACHINOS is presented, where the 3D printed central component is coated in a Diamond-Like Carbon (DLC) layer. The production and testing of the structure, in terms of stability and resolution, is described. Further applications in fundamental physics and industry are also discussed.

physics.ins-det↗

Development of a Simulation Framework for Spherical Proportional Counters

The spherical proportional counter is a novel gaseous detector with numerous applications, including direct dark matter searches and neutron spectroscopy. The strengths of the Geant4 and Garfield++ toolkits are combined to create a simulation framework for spherical proportional counters. The interface is implemented by introducing Garfield++ classes within a Geant4 application. Simulated muon, electron, and photon signals are presented, and the effects of gas mixture composition and anode support structure on detector response are discussed.

physics.ins-det↗

Experimental Determination of Proton Hardness Factors at Several Irradiation Facilities

The scheduled High Luminosity upgrade of the CERN Large Hadron Collider presents new challenges in terms of radiation hardness. As a consequence, campaigns to qualify the radiation hardness of detector sensors and components are undertaken worldwide. The effects of irradiation with beams of different particle species and energy, aiming to assess displacement damage in semiconductor devices, are communicated in terms of the equivalent 1 MeV neutron fluence, using the hardness factor for the conversion. In this work, the hardness factors for protons at three different kinetic energies have been measured by analysing the I-V and C-V characteristics of reverse biased diodes, pre- and post-irradiation. The sensors were irradiated at the MC40 Cyclotron of the University of Birmingham, the cyclotron at the Karlsruhe Institute of Technology, and the IRRAD proton facility at CERN, with the respective measured proton hardness factors being: 2.1 +/- 0.5 for 24 MeV, 2.2 +/- 0.4 for 23 MeV, and 0.62 +/- 0.04 for 23 GeV. The hardness factors currently used in these three facilities are in agreement with the presented measurements.

physics.ins-det↗

Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment

Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.

physics.ins-det↗

A sparkless resistive glass correction electrode for the spherical proportional counter

A new anode support structure for the spherical proportional counter is presented that incorporates a resistive correction electrode made of glass. This electrode improves the electric field homogeneity versus angle while suppressing the probability and intensity of sparks compared to non-resistive alternatives. The configuration of the correction electrode was optimised with simulations. Such support structures have been constructed and measurements have demonstrated homogeneous response of the detector and operational stability. A measurement of the resistivity of the glass used is also presented.

physics.ins-det↗

Studying the effect of Polarisation in Compton scattering in the undergraduate laboratory

An experiment for the advanced undergraduate laboratory allowing students to directly observe the effect of photon polarisation on Compton scattering is described. An initially unpolarised beam of photons is polarised via Compton scattering and analysed through a subsequent scattering. The experiment is designed to use equipment typically available at an undergraduate physics laboratory. The experimental results are compared with a Geant4 simulation and geometry effects are discussed.

physics.ed-ph↗