SearcharxivSearch

arXiv subjects

P. L. Wilson

Publications and source records attributed to P. L. Wilson.

2 recordsLinked to original sources

Numerical Study of Flow Structure and Pedestrian Level Wind Comfort Inside Urban Street Canyons

In this work we numerically investigate the flow conditions inside uniform and non-uniform street canyons well within the atmospheric boundary layer. The numerical simulations use the steady RANS method with the near-wall modelling approach to simulate wall roughness at the boundary. With the aim of investigating both flow structure in broad terms, and pedestrian comfort in the street canyon between parallel buildings, we test different canyon configurations with varied street width, building width and building height. Turbulent conditions are broadly expected to hold within the physically-realistic range of Reynolds number of order $10^6$ considered here, where we take the building height to be a characteristic length scale, and the free stream velocity as the characteristic velocity. In addition to discussing the features of the canyon and wake flow, we investigate the effects of canyon geometry on pedestrian comfort by using the Extended Land Beaufort Scale for this purpose. We present and compare pedestrian comfort maps for each of our geometries.

physics.flu-dyn

Application of a spring-dashpot system to clinical lung tumor motion data

A spring-dashpot system based on the Voigt model was developed to model the correlation between abdominal respiratory motion and tumor motion during lung radiotherapy. The model was applied to clinical data comprising 52 treatment beams from 10 patients, treated on the Mitsubishi Real-Time Radiation Therapy system, Sapporo, Japan. In Stage 1, model parameters were optimized for individual patients and beams to determine reference values and to investigate how well the model can describe the data. In Stage 2, for each patient the optimal parameters determined for a single beam were applied to data from other beams to investigate whether a beam-specific set of model parameters is sufficient to model tumor motion over a course of treatment. In Stage 1 the baseline root mean square (RMS) residual error for all individually-optimized beam data was 0.90 plus or minus 0.40 mm. In Stage 2, patient-specific model parameters based on a single beam were found to model the tumor position closely, even for irregular beam data, with a mean increase with respect to Stage 1 values in RMS error of 0.37 mm. On average the obtained model output for the tumor position was 95% of the time within an absolute bound of 2.0 mm and 2.6 mm in Stage 1 and 2, respectively. The model was capable of dealing with baseline, amplitude and frequency variations of the input data, as well as phase shifts between the input tumor and output abdominal signals. These results indicate that it may be feasible to collect patient-specific model parameters during or prior to the first treatment, and then retain these for the rest of the treatment period. The model has potential for clinical application during radiotherapy treatment of lung tumors.

physics.med-ph