SearcharxivSearch

arXiv subjects

P. Lu

Publications and source records attributed to P. Lu.

16 recordsLinked to original sources

Direct integration of atomic precision advanced manufacturing into middle-of-line silicon fabrication

Atomic precision advanced manufacturing (APAM) dopes silicon with enough carriers to change its electronic structure and can be used to create novel devices by defining metallic regions whose boundaries have single-atom abruptness. Incompatibility with the thermal and lithography process requirements for gated silicon transistor manufacturing have inhibited exploration of both how APAM can enhance CMOS performance and how transistor manufacturing steps can accelerate the discovery of new APAM device concepts. In this work, we introduce an APAM process that enables direct integration into the middle of a transistor manufacturing workflow. We show that a process that combines sputtering and annealing with a hardmask preserves a defining characteristic of APAM, a doping density far in excess of the solid solubility limit, while trading another, the atomic precision, for compatibility with manufacturing. The electrical characteristics of a chip combining a transistor with an APAM resistor show that the APAM module has only affected the transistor through the addition of a resistance and not by altering the transistor. This proof-of-concept demonstration also outlines the requirements and limitations of a unified APAM tool, which could be introduced into manufacturing environments, greatly expanding access to this technology and inspiring a new generation of devices with it.

physics.app-ph

Assembly, testing, and installation of mPMT photosensor for the Water Cherenkov Test Experiment

The multi-Photomultiplier Tube (mPMT) photosensors will be used in the Water Cherenkov Test Experiment (WCTE) to efficiently detect the photons produced in the whole detector. One of the aims behind the development of WCTE is to test the technology and implement it in future water Cherenkov experiments such as the Hyper-Kamiokande experiment and its Intermediate Water Cherenkov Detector. Each mPMT is built using nineteen 3-inch PMTs arranged on a semi-spherical support matrix. In this paper, we describe the design and manufacture of the mechanical components, the procedures for casting an optical gel between PMTs and acrylic cover, and the overall assembly procedure of the mPMTs. Details of the electronics used in the mPMT modules are not included in this paper and will be presented in a separate publication. We also report on the R&D performed on the selection of the optical gel ratio along with transmittance measurements and the reflectance measurements performed on the aluminium reflector. We also present the optical tests performed on the mPMT module using a 405 nm LED and the resulting increase in the effective photosensitive area by surrounding the PMTs with a reflector. A summary of the production and installation of the mPMTs for the WCTE is also presented in this paper.

physics.ins-det

Epitaxial aluminum layer on antimonide heterostructures for exploring Josephson junction effects

In this article, we present results of our recent work of epitaxially-grown aluminum (epi-Al) on antimonide heterostructures, where the epi-Al thin film is grown at either room temperature or below zero $^o$C. A sharp superconducting transition at $T \sim 1.3$ K is observed in these epi-Al films. We further show that supercurrent states are realized in Josephson junctions fabricated in the epi-Al/antimonide heterostructures with mobility $\mu \sim 1.0 \times 10^6$ cm$^2$/Vs. These results clearly demonstrate we have achieved growing high-quality epi-Al/antimonide heterostructures, a promising platform for the exploration of Josephson junction effects for quantum information science and microelectronics applications.

cond-mat.mtrl-sci

Noise reduction in qubit readout with a two-mode squeezed interferometer

Fault-tolerant quantum information processing with flawed qubits and gates requires highly efficient, quantum non-demolition (QND) qubit readout. In superconducting circuits, qubit readout using coherent light with fidelity above 99% has been achieved by using quantum-limited parametric amplifiers such as the Josephson Parametric Converter (JPC). However, further improvement of such measurement is fundamentally limited by the vacuum fluctuations of the coherent light used for readout. In this work we measure a transmon qubit/cavity system with an unbalanced two-mode squeezed light interferometer formed from two JPCs. The first amplifier generates two-mode squeezed vacuum at its output, which is coherently recombined by the second amplifier after one branch is shifted and displaced by the transmon's state after it interacts with the qubit/cavity system on one arm of the interferometer. We have observed a 31% improvement in power Signal-to-Noise Ratio (SNR) of projective readout compared to that of coherent light readout in the same system. To investigate the quantum properties of the two-mode squeezed light in the system, we also studied weak measurement and found, surprisingly, that tuning the interferometer to be as unprojective as possible was associated with an increase in the quantum efficiency of our readout relative to the optimum setting for projective measurement. These enhancements may enable remote entanglement with lower efficiency components in a system with qubits in both arms of the interferometer.

quant-ph

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic

Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.

physics.med-ph

The Berkeley sample of Type II supernovae: BVRI light curves and spectroscopy of 55 SNe II

In this work, BV RI light curves of 55 Type II supernovae (SNe II) from the Lick Observatory Supernova Search program obtained with the Katzman Automatic Imaging Telescope and the 1 m Nickel telescope from 2006 to 2018 are presented. Additionally, more than 150 spectra gathered with the 3 m Shane telescope are published. We conduct an analyse of the peak absolute magnitudes, decline rates, and time durations of different phases of the light and colour curves. Typically, our light curves are sampled with a median cadence of 5.5 days for a total of 5093 photometric points. In average V-band plateau declines with a rate of 1.29 mag (100 days)-1, which is consistent with previously published samples. For each band, the plateau slope correlates with the plateau length and the absolute peak magnitude: SNe II with steeper decline have shorter plateau duration and are brighter. A time-evolution analysis of spectral lines in term of velocities and pseudoequivalent widths is also presented in this paper. Our spectroscopic sample ranges between 1 and 200 days post-explosion and has a median ejecta expansion velocity at 50 days post-explosion of 6500 km/s (Halpha line) and a standard dispersion of 2000 km/s. Nebular spectra are in good agreement with theoretical models using a progenitor star having a mass <16 Msol. All the data are available to the community and will help to understand SN II diversity better, and therefore to improve their utility as cosmological distance indicators.

astro-ph.HE

Multiparametric Amplification and Qubit Measurement with a Kerr-free Josephson Ring Modulator

Josephson-junction based parametric amplifiers have become a ubiquitous component in superconducting quantum machines. Although parametric amplifiers regularly achieve near-quantum limited performance, they have many limitations, including low saturation powers, lack of directionality, and narrow bandwidth. The first is believed to stem from the higher order Hamiltonian terms endemic to Josephson junction circuits, and the latter two are direct consequences of the nature of the parametric interactions which power them. In this work, we attack both of these issues. First, we have designed a new, linearly shunted Josephson Ring Modulator (JRM) which nearly nulls all 4th-order terms at a single flux bias point. Next, we achieve gain through a pair of balanced parametric drives. When applied separately, these drives produce phase-preserving gain (G) and gainless photon conversion (C), when applied together, the resultant amplifier (which we term GC) is a bi-directional, phase-sensitive transmission-only amplifier with a large, gain-independent bandwidth. Finally, we have also demonstrated the practical utility of the GC amplifier, as well as its' quantum efficiency, by using it to read out a superconducting transmon qubit.

quant-ph

In-beam internal conversion electron spectroscopy with the SPICE detector

The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $\gamma$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect and direct internal conversion electrons emitted from nuclear reactions to a thick, highly segmented, lithium-drifted silicon detector. This arrangement, combined with TIGRESS, enables in-beam $\gamma$-ray and internal conversion electron spectroscopy to be performed with stable and radioactive ion beams. Technical aspects of the device, capabilities, and initial performance are presented.

physics.ins-det

Electrical-current-induced magnetic hysteresis in self-assembled vertically aligned La_{2/3}Sr_{1/3}MnO_3:ZnO-nanopillar composites

Magnetoresistive random-access memory (MRAM) is poised to become a next-generation information storage device. Yet, many materials challenges remain unsolved before it can become a widely used memory storage solution. Among them, an urgent need is to identify a material system that is suitable for downscaling and is compatible with low-power logic applications. Self-assembled, vertically-aligned La_{2/3}Sr_{1/3}MnO_3:ZnO nanocomposites, in which La_{2/3}Sr_{1/3}MnO_3 (LSMO) matrix and ZnO nanopillars form an intertwined structure with coincident-site-matched growth occurring between the LSMO and ZnO vertical interfaces, may offer new MRAM applications by combining their superior electric, magnetic (B), and optical properties. In this paper, we show the results of electrical current induced magnetic hysteresis in magneto-resistance measurements in these nano-pillar composites. We observe that when the current level is low, for example, 1 uA, the magneto-resistance displays a linear, negative, non-hysteretic B field dependence. Surprisingly, when a large current is used, I > 10 uA, a hysteretic behavior is observed when the B field is swept in the up and down directions. This hysteresis weakens as the sample temperature is increased. A possible spin-valve mechanism related to this electrical current induced magnetic hysteresis is proposed and discussed.

cond-mat.mtrl-sci

Quantum Oscillations at Integer and Fractional Landau Level Indices in ZrTe5

A three-dimensional (3D) Dirac semimetal (DS) is an analogue of graphene, but with linear energy dispersion in all (three) momentum directions.3D DSs have been a fertile playground in discovering novel quantum particles, for example Weyl fermions, in solid state systems.Many 3D DSs (e.g., ZrTe5) were theoretically predicted. We report here the results from the studies of aberration-corrected scanning transmission electron microscopy and low temperature magneto-transport measurements in exfoliated ZrTe5 thin flakes.Several unique results were observed. First, an anomalous-Hall-effect-like behavior was observed around zero magnetic field (B).Second, a non-trivial Berry's phase of \pi\ was obtained from the Landau level fan diagram of the Shubnikov-de Haas oscillations in the longitudinal resistivity. Third, the longitudinal resistivity shows linear B field dependence in the quantum limit. Most surprisingly, quantum oscillations were observed at fractional Landau level indices N = 2/3 and 2/5, demonstrating strong electron-electron interactions effects in ZrTe5.

cond-mat.mtrl-sci

The binary mass transfer origin of the red blue straggler sequence in M30

Two separated sequences of blue straggler stars (BSSs) have been revealed by Ferraro et al. (2009) in the color-magnitude diagram (CMD) of the Milky Way globular cluster M30. Their presence has been suggested to be related to the two BSS formation channels (namely, collisions and mass-transfer in close binaries) operating within the same stellar system. The blue sequence was indeed found to be well reproduced by collisional BSS models. In contrast, no specific models for mass transfer BSSs were available for an old stellar system like M30. Here we present binary evolution models, including case-B mass transfer and binary merging, specifically calculated for this cluster. We discuss in detail the evolutionary track of a $0.9+0.5 M_\odot$ binary, which spends approximately 4 Gyr in the BSS region of the CMD of a 13 Gyr old cluster. We also run Monte-Carlo simulations to study the distribution of mass transfer BSSs in the CMD and to compare it with the observational data. Our results show that: (1) the color and magnitude distribution of synthetic mass transfer BSSs defines a strip in the CMD that nicely matches the observed red BSS sequence, thus providing strong support to the mass transfer origin for these stars; (2) the CMD distribution of synthetic BSSs never attains the observed location of the blue BSS sequence, thus reinforcing the hypothesis that the latter formed through a different channel (likely collisions); (3) most ($\sim 60\%$) of the synthetic BSSs are produced by mass-transfer models, while the remaining $< 40\%$ requires the contribution from merger models.

astro-ph.SR

Induced magnetization in La$_{0.7}$Sr$_{0.3}$MnO$_3$/BiFeO$_3$ superlattices

Using polarized neutron reflectometry (PNR), we observe an induced magnetization of 75$\pm$ 25 kA/m at 10 K in a La$_{0.7}$Sr$_{0.3}$MnO$_3$ (LSMO)/BiFeO$_3$ superlattice extending from the interface through several atomic layers of the BiFeO$_3$ (BFO). The induced magnetization in BFO is explained by density functional theory, where the size of bandgap of BFO plays an important role. Considering a classical exchange field between the LSMO and BFO layers, we further show that magnetization is expected to extend throughout the BFO, which provides a theoretical explanation for the results of the neutron scattering experiment.

cond-mat.str-el

Universal High Order Subroutine with New Shock Detector for Shock Boundary Layer Interaction

The goal of this work is to develop a new universal high order subroutine for shock boundary layer interaction. First, an effective shock/discontinuity detector has been developed.The detector has two steps.The first step is to check the ratio of the truncation errors on the coarse and fine grids and the second step is to check the local ratio of the left and right slopes. The currently popular shock/discontinuity detectors can detect shock, but mistake high frequency waves and critical points as shock and then damp the physically important high frequency waves.Preliminary results show the new shock/discontinuity detector is very delicate and can detect all shocks including strong, weak and oblique shocks or discontinuity in function and the first, second, and third order derivatives without artificial constants, but never mistake high frequency waves and critical points, expansion waves as shock. This will overcome the bottle neck problem with numerical simulation for the shock-boundary layer interaction, shock-acoustic interaction, image process, porous media flow, multiple phase flow and anywhere the high frequency waves are important, but discontinuity exists and is mixed with high frequency waves. After detecting the shock we can then use one side high order scheme for shocks and high order central compact scheme for the rest if the shock is appropriately located. Then a high order universal subroutine for finite difference method is developed which can be used for any finite difference code for accurate numerical derivatives.

physics.comp-ph

A new measurement method of electrode gains for orthogonal symmetric type beam position monitor

The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in electronic gain and mismachining tolerance can cause the change of the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions in order to bring the measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is irrelevant to the beam charge and the related coefficient can be theoretical calculated. The effect of electrodes coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.

physics.acc-ph

Simulations of a micro-PET System based on Liquid Xenon

The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of large area avalanche photodiodes for the measurement of ionization charge and scintillation light. A key feature of the LXePET system is the ability to identify individual photon interactions with high energy resolution and high spatial resolution in 3 dimensions and determine the correct interaction sequence using Compton reconstruction algorithms. The simulated LXePET imaging performance was evaluated by computing the noise equivalent count rate, the sensitivity and point spread function for a point source, and by examining the image quality using a micro-Derenzo phantom according to the NEMA-NU4 standard. Results of these simulation studies included NECR peaking at 1326 kcps at 188 MBq (705 kcps at 184 MBq) for an energy window of 450 - 600 keV and a coincidence window of 1 ns for mouse (rat) phantoms. The absolute sensitivity at the center of the field of view was 12.6%. Radial, tangential, and axial resolutions of 22Na point sources reconstructed with a list-mode maximum likelihood expectation maximization algorithm were <= 0.8 mm (FWHM) throughout the field of view. Hot-rod inserts of < 0.8 mm diameter were resolvable in the transaxial image of a micro-Derenzo phantom. The simulations show that a liquid xenon system would provide new capabilities for significantly enhancing PET images.

physics.med-ph

Simultaneous reconstruction of scintillation light and ionization charge produced by 511 keV photons in liquid xenon : potential application to PET

In order to assess the performance of liquid xenon detectors for use in positron emission tomography we studied the scintillation light and ionization charge produced by 511 keV photons in a small prototype detector. Scintillation light was detected with large area avalanche photodiodes while ionization electrons were collected on an anode instrumented with low noise electronics after drifting up to 3 cm. Operational conditions were studied as a function of the electric field. Energy resolutions of <10 % (FWHM) were achieved by combining the scintillation light and ionization charge signals. The relationship between scintillation light and ionization signals was investigated. An analysis of the sources of fluctuations was performed in order to optimize future detector designs.

physics.ins-det