SearcharxivSearch

arXiv subjects

P. Meyer

Publications and source records attributed to P. Meyer.

2 recordsLinked to original sources

Assessing Pancreatic Ductal Adenocarcinoma Vascular Invasion: the PDACVI Benchmark

Surgical resection remains the only potentially curative treatment for pancreatic ductal adenocarcinoma (PDAC), and eligibility depends on accurate assessment of vascular invasion (VI), i.e., tumor extension into adjacent critical vessels. Despite its importance for preoperative staging and surgical planning, computational VI assessment remains underexplored. Two major challenges are the lack of public datasets and the diagnostic ambiguity at the tumor-vessel interface, which leads to substantial inter-rater variability even among expert radiologists. To address these limitations, we introduce the CURVAS-PDACVI Dataset and Challenge, an open benchmark for uncertainty-aware AI in PDAC staging based on a densely annotated dataset with five independent expert annotations per scan. We also propose a multi-metric evaluation framework that extends beyond spatial overlap to include probabilistic calibration and VI assessment. Evaluation of six state-of-the-art methods shows that strong global volumetric overlap does not necessarily translate into reliable performance at clinically critical tumor-vessel interfaces. In particular, methods optimized for binary segmentation perform competitively on average overlap metrics, but often degrade in high-complexity cases with low expert consensus, either collapsing in volume or overextending at uncertain boundaries. In contrast, methods that model inter-rater disagreement produce better calibrated probabilistic maps and show greater robustness in these ambiguous cases. The benchmark highlights the limitations of volumetric accuracy as a proxy for localized surgical utility, motivating uncertainty-aware probabilistic models for preoperative decision-making.

cs.CV

Response Uniformity of the ATLAS Liquid Argon Electromagnetic Calorimeter

The construction of the ATLAS electromagnetic liquid argon calorimeter modules is completed and all the modules are assembled and inserted in the cryostats. During the production period four barrel and three endcap modules were exposed to test beams in order to assess their performance, ascertain the production quality and reproducibility, and to scrutinize the complete energy reconstruction chain from the readout and calibration electronics to the signal and energy reconstruction. It was also possible to check the full Monte Carlo simulation of the calorimeter. The analysis of the uniformity, resolution and extraction of constant term is presented. Typical non-uniformities of 0.5% and typical global constant terms of 0.6% are measured for the barrel and end-cap modules.

physics.ins-det