SearcharxivSearch

arXiv subjects

P. Micke

Publications and source records attributed to P. Micke.

14 recordsLinked to original sources

Thorium-229 in its Highest Charge States: Single-Ion Nuclear Clocks for Tests of Fundamental Interactions

The prospects and the implementation of single-ion nuclear clocks of $^{229}$Th$^{q+}$ ions in their highest charge states $q=90, \ldots, 87$ are discussed. Highly-ionized-thorium clocks are ideal for tests of fundamental interactions since the ions are elementary quantum systems composed of only a few building blocks. Two cases of $^{229}$Th$^{q+}$ clocks excel: a) one-electron $^{229}$Th$^{89+}$ that combines two nuclear-clock transitions in the VUV with hyperfine IR atomic-clock transitions, and, b) fully ionized $^{229}$Th$^{90+}$ which constitutes the prototype of a nuclear clock, one without any electrons. We evaluate the feasibility of such clocks by means of quantum logic spectroscopy (QLS) in linear Paul traps. Due to its universal nature, the QLS approach allows for systematic clock comparisons using different charge states as well as different spectroscopy transitions on the same experimental platform. A valuable asset towards single-ion $^{229}$Th$^{q+}$ clocks is the process of nuclear hyperfine mixing that enables the tunability of the natural linewidth of the clock transition over more than five orders of magnitude by changing the charge state.

physics.atom-ph

Nonlinear calcium King plot constrains new bosons and nuclear properties

Nonlinearities in King plots (KP) of isotope shifts (IS) can reveal the existence of beyond-Standard-Model (BSM) interactions that couple electrons and neutrons. However, it is crucial to distinguish higher-order Standard Model (SM) effects from BSM physics. We measure the IS of the transitions ${{}^{3}P_{0}~\rightarrow~{}^{3}P_{1}}$ in $\mathrm{Ca}^{14+}$ and ${{}^{2}S_{1/2} \rightarrow {}^{2}D_{5/2}}$ in $\mathrm{Ca}^{+}$ with sub-Hz precision as well as the nuclear mass ratios with relative uncertainties below $4\times10^{-11}$ for the five stable, even isotopes of calcium (${}^{40,42,44,46,48}\mathrm{Ca}$). Combined, these measurements yield a calcium KP nonlinearity with a significance of $\sim 900 \sigma$. Precision calculations show that the nonlinearity cannot be fully accounted for by the expected largest higher-order SM effect, the second-order mass shift, and identify the little-studied nuclear polarization as the only remaining SM contribution that may be large enough to explain it. Despite the observed nonlinearity, we improve existing KP-based constraints on a hypothetical Yukawa interaction for most of the new boson masses between $10~\mathrm{eV/c^2}$ and $10^7~\mathrm{eV/c^2}$.

physics.atom-ph

Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons

We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.

physics.atom-ph

Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature

We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.

physics.atom-ph

Ultra thin polymer foil cryogenic window for antiproton deceleration and storage

We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $\mu$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons through the window, we tested the degrading properties of different aluminium coated PET foils of thicknesses between 900nm and 2160nm, concluding that 1760nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature, and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of 7 holes with 1 mm diameter and will transmit up to 2.5% of the injected 100keV antiproton beam delivered by the AD/ELENA-facility of CERN.

physics.ins-det

BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies

Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.

physics.ins-det

Testing CPT Invariance by High-Precision Comparisons of Fundamental Properties of Protons and Antiprotons at BASE

The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previous measurement campaigns, we measured the magnetic moments of the proton and the antiproton, reaching (sub-)parts-in-a-billion fractional uncertainty. In the latest campaign, we have compared the proton and antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts in a trillion. In this contribution, we give an overview of the measurement campaign, and detail how its results are used to constrain nine spin-independent coefficients of the Standard-Model Extension in the proton and electron sector.

hep-ex

A new benchmark of soft X-ray transition energies of Ne, CO$_2$, and SF$_6$: paving a pathway towards ppm accuracy

A key requirement for the correct interpretation of high-resolution X-ray spectra is that transition energies are known with high accuracy and precision. We investigate the K-shell features of Ne, CO$_2$, and SF$_6$ gases, by measuring their photo ion-yield spectra at the BESSY II synchrotron facility simultaneously with the 1s-np fluorescence emission of He-like ions produced in the Polar-X EBIT. Accurate ab initio calculations of transitions in these ions provide the basis of the calibration. While the CO$_2$ result agrees well with previous measurements, the SF$_6$ spectrum appears shifted by ~0.5 eV, about twice the uncertainty of the earlier results. Our result for Ne shows a large departure from earlier results, but may suffer from larger systematic effects than our other measurements. The molecular spectra agree well with our results of time-dependent density functional theory. We find that the statistical uncertainty allows calibrations in the desired range of 1-10 meV, however, systematic contributions still limit the uncertainty to ~40-100 meV, mainly due to the temporal stability of the monochromator energy scale. Combining our absolute calibration technique with a relative energy calibration technique such as photoelectron energy spectroscopy will be necessary to realize its full potential of achieving uncertainties as low as 1-10 meV.

astro-ph.IM

An ultralow-noise superconducting radio-frequency ion trap for frequency metrology with highly charged ions

We present a novel ultrastable superconducting radio-frequency (RF) ion trap realized as a combination of an RF cavity and a linear Paul trap. Its RF quadrupole mode at 34.52 MHz reaches a quality factor of $Q\approx2.3\times 10^5$ at a temperature of 4.1 K and is used to radially confine ions in an ultralow-noise pseudopotential. This concept is expected to strongly suppress motional heating rates and related frequency shifts which limit the ultimate accuracy achieved in advanced ion traps for frequency metrology. Running with its low-vibration cryogenic cooling system, electron beam ion trap and deceleration beamline supplying highly charged ions (HCI), the superconducting trap offers ideal conditions for optical frequency metrology with ionic species. We report its proof-of-principle operation as a quadrupole mass filter with HCI, and trapping of Doppler-cooled ${}^9\text{Be}^+$ Coulomb crystals.

physics.atom-ph

The Heidelberg compact electron beam ion traps

Electron beam ion traps (EBIT) are ideal tools for both production and study of highly charged ions (HCI). In order to reduce their construction, maintenance, and operation costs we have developed a novel, compact, room-temperature design, the Heidelberg Compact EBIT (HC-EBIT). Four already commissioned devices operate at the strongest fields (up to 0.86 T) reported for such EBITs using permanent magnets, run electron beam currents up to 80 mA and energies up to 10 keV. They demonstrate HCI production, trapping, and extraction of pulsed Ar$^{16+}$ bunches and continuous 100 pA ion beams of highly charged Xe up to charge state 29+, already with a 4 mA, 2 keV electron beam. Moreover, HC-EBITs offer large solid-angle ports and thus high photon count rates, e. g., in x-ray spectroscopy of dielectronic recombination in HCIs up to Fe$^{24+}$, achieving an electron-energy resolving power of $E/\Delta E > 1500$ at 5 keV. Besides traditional on-axis electron guns, we have also implemented a novel off-axis gun for laser, synchrotron, and free-electron laser applications, offering clear optical access along the trap axis. We report on its first operation at a synchrotron radiation facility demonstrating resonant photoexcitation of highly charged oxygen.

physics.atom-ph

Coherent laser spectroscopy of highly charged ions using quantum logic

Precision spectroscopy of atomic systems is an invaluable tool for the advancement of our understanding of fundamental interactions and symmetries. Recently, highly charged ions (HCI) have been proposed for sensitive tests of physics beyond the Standard Model and as candidates for high-accuracy atomic clocks. However, the implementation of these ideas has been hindered by the parts-per-million level spectroscopic accuracies achieved to date. Here, we cool a trapped HCI to the lowest reported temperatures, and introduce coherent laser spectroscopy on HCI with an eight orders of magnitude leap in precision. We probe the forbidden optical transition in $^{40}$Ar$^{13+}$ at 441 nm using quantum-logic spectroscopy and measure both its excited-state lifetime and $g$-factor. Our work ultimately unlocks the potential of HCI, a large, ubiquitous atomic class, for quantum information processing, novel frequency standards, and highly sensitive tests of fundamental physics, such as searching for dark matter candidates or violations of fundamental symmetries.

physics.atom-ph

High-Precision Determination of Oxygen-K$\alpha$ Transition Energy Excludes Incongruent Motion of Interstellar Oxygen

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O$_2$ with 8 meV uncertainty. We reveal a systematic $\sim$450 meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O$_2$ literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

physics.atom-ph

Non-linear isotope-shift effects in Be-like, B-like, and C-like argon

Violation of linearity of the King plot is investigated for a chain of partially stripped argon isotopes. The nonlinearity originates within the Standard Model from subtle contributions to the isotope shifts from next-to-leading order effects, which have never been systematically studied so far. In light atoms these nonlinear effects are dominated by the quadratic nuclear recoil ($\propto 1/M^2$ where $M$ is the nuclear mass). Large-scale relativistic calculations of the linear and quadratic mass shift and the field shift are performed for the $2P$ fine-structure transitions in Be-like, B-like, and C-like argon ions. Nonlinearities of the King plots from 5 to 30 kHz are found, which is four orders of magnitude larger than previous estimates in comparable systems. Accurate calculations of these effects are vital for identification of possible nonlinearities originating from physics beyond the Standard Model.

physics.atom-ph

Closed-cycle, low-vibration 4 K cryostat for ion traps and other applications

In-vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times for example in ion traps, essential requirements for experiments with highly charged ions, quantum computation, and optical clocks. We have developed a novel cryostat continuously refrigerated with a pulse-tube cryocooler and providing the lowest vibration level reported for such a closed-cycle system with 1 W cooling power for a <5 K experiment. A decoupling system suppresses vibrations from the cryocooler by three orders of magnitude down to a level of 10 nm peak amplitudes in the horizontal plane. Heat loads of about 40 W (at 45 K) and 1 W (at 4 K) are transferred from an experimental chamber, mounted on an optical table, to the cryocooler through a vacuum-insulated massive 120 kg inertial copper pendulum. The 1.4 m long pendulum allows installation of the cryocooler in a separate, acoustically isolated machine room. In the laser laboratory, we measured the residual vibrations using an interferometric setup. The positioning of the 4 K elements is reproduced to better than a few micrometer after a full thermal cycle to room temperature. Extreme high vacuum on the $10^{-15}$ mbar level is achieved. In collaboration with the Max-Planck-Intitut f\"ur Kernphysik (MPIK), such a setup is now in operation at the Physikalisch-Technische Bundesanstalt (PTB) for a next-generation optical clock experiment using highly charged ions.

physics.atom-ph