SearcharxivSearch

arXiv subjects

P. Mitra

Publications and source records attributed to P. Mitra.

At least 19 recordsLinked to original sources

Removal of spallation-induced tritium from silicon through diffusion

Tritium, predominantly produced through spallation reactions caused by cosmic ray interactions, is a significant radioactive background for silicon-based rare event detection experiments, such as dark matter searches. We have investigated the feasibility of removing cosmogenic tritium from high-purity silicon intended for use in low-background experiments. We demonstrate that significant tritium removal is possible through diffusion by subjecting silicon to high-temperature (> 400C) baking. Using an analytical model for the de-trapping and diffusion of tritium in silicon, our measurements indicate that cosmogenic tritium diffusion constants are comparable to previous measurements of thermally-introduced tritium, with complete de-trapping and removal achievable above 750C. This approach has the potential to alleviate the stringent constraints of cosmic ray exposure prior to device fabrication and significantly reduce the cosmogenic tritium backgrounds of silicon-based detectors for next-generation rare event searches.

physics.ins-det

Absorption of Fermionic Dark Matter in the PICO-60 C$_{3}$F$_{8}$ Bubble Chamber

Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a non-relativistic effective field theory framework. An analysis of data from the PICO-60 C$_{3}$F$_{8}$ bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/$\textit{c}^2$ and establishes the first limits on spin-dependent absorptive interactions. These results demonstrate the sensitivity of bubble chambers to low-mass dark matter and underscore the importance of absorption searches in expanding the parameter space of direct detection experiments.

hep-ex

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_{\chi}$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.

physics.ins-det

Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M

Dark Matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1$e^-$ events with sidereal period, where a DM signal would appear. We then use these data to place exclusion limits on DM in the mass range [0.53, 2.7] MeV/c$^2$ interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by $\sim$2 orders of magnitude on our previous limit obtained from the total rate of 1$e^-$ events, using the same data set. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c$^2$.

hep-ex

Reconstructing Air Shower Parameters with MGMR3D

Measuring the radio emission from cosmic ray particle cascades has proven to be a very efficient method to determine their properties such as the mass composition. Efficient modeling of the radio emission from air showers is crucial in order to extract the cosmic ray physics parameters from the measured radio emission. MGMR3D is a fast semi-analytic code that calculates the complete radio footprint, i.e.\ intensity, polarization, and pulse shapes, for a parametrized shower-current density and can be used in a chi-square optimization to fit a given radio data. It is many orders of magnitude faster than its Monte Carlo counterparts. We provide a detailed comparative study of MGMR3D to Monte Carlo simulations, where, with improved parametrizations, the shower maximum $\Xmax$ is found to have very strong agreement with a small dependency on the incoming zenith angle of the shower. Another interesting feature we observe with MGMR3D is sensitivity to the shape of the longitudinal profile in addition to $\Xmax$. This is achieved by probing the distinguishable radio footprint produced by a shower having a different longitudinal profile than usual. Furthermore, for the first time, we show the results of reconstructing shower parameters for LOFAR data using MGMR3D, and obtaining a $\Xmax$ resolution of 22 g/cm$^2$ and energy resolution of 19\%.

astro-ph.HE

Constraining the cosmic-ray mass composition by measuring the shower length with SKA

The current generation of air shower radio arrays has demonstrated that the atmospheric depth of the shower maximum Xmax can be reconstructed with high accuracy. These experiments are now contributing to mass composition studies in the energy range where a transition from galactic to extragalactic cosmic-ray sources is expected. However, we are still far away from an unambiguous interpretation of the data. Here we propose to use radio measurements to derive a new type of constraint on the mass composition, by reconstructing the shower length L. The low-frequency part of the Square Kilometer Array will have an extremely high antenna density of roughly 60.000 antennas within one square kilometer, and is the perfect site for high-resolution studies of air showers. In this contribution, we discuss the impact of being able to reconstruct L, and the unique contribution that SKA can make to cosmic-ray science.

astro-ph.HE

A high-precision interpolation method for pulsed radio signals from cosmic-ray air showers

Analysis of radio signals from cosmic-ray induced air showers has been shown to be a reliable method to extract shower parameters such as primary energy and depth of shower maximum. The required detailed air shower simulations take 1 to 3 days of CPU time per shower for a few hundred antennas. With nearly $60,000$ antennas envisioned to be used for air shower studies at the Square Kilometre Array (SKA), simulating all of these would come at unreasonable costs. We present an interpolation algorithm to reconstruct the full pulse time series at any position in the radio footprint, from a set of antennas simulated on a polar grid. Relying on Fourier series representations and cubic splines, it significantly improves on existing linear methods. We show that simulating about 200 antennas is sufficient for high-precision analysis in the SKA era, including e.g. interferometry which relies on accurate pulse shapes and timings. We therefore propose the interpolation algorithm and its implementation as a useful extension of radio simulation codes, to limit computational effort while retaining accuracy.

astro-ph.IM

Prospects for measuring the longitudinal particle distribution of cosmic-ray air showers with SKA

We explore the possibilities of measuring the longitudinal profile of individual air showers beyond $X_{\rm max}$ when using very dense radio arrays such as SKA. The low-frequency part of the Square Kilometre Array, to be built in Australia, features an enormous antenna density of about $50,000$ antennas in the inner core region of radius 500 m, with a frequency band from 50 to 350 MHz. From CoREAS simulations, a SKA-Low antenna model plus noise contributions, and adapted LOFAR analysis scripts, we obtain a resolution in the shower maximum $X_{\rm max}$ and energy that is considerably better than at LOFAR. Already from this setup, we show that at least one additional parameter of the longitudinal profile can be measured. This would improve mass composition analysis by measuring an additional composition-dependent quantity. Moreover, it would offer an opportunity to discriminate between the different predictions of hadronic interaction models, hence contributing to hadronic physics at energy levels beyond man-made accelerators.

astro-ph.HE

First Constraints from DAMIC-M on Sub-GeV Dark-Matter Particles Interacting with Electrons

We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the subelectron charge resolution and low level of dark current of DAMIC-M charge-coupled devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7e$^-$. With this dataset we place limits on dark matter particles of mass between 0.53 and 1000 MeV/$c^2$, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/$c^2$ and [1.5,15.1] MeV/$c^2$ for ultralight and heavy mediator interactions, respectively.

hep-ex

Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers

PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.

astro-ph.CO

The DAMIC-M Experiment: Status and First Results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

hep-ex

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $\gamma$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$ $initio$ calculations originally developed for X-ray absorption spectroscopy.

physics.ins-det

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

physics.ins-det

Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber

Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.

astro-ph.CO

Determining Atmospheric Electric Fields using MGMR3D

Cosmic-ray particles impinging on the atmosphere induce high-energy particle cascades in air, an Extensive Air Shower (EAS), emitting coherent radio emission. This emission is affected by the presence of strong electric fields during thunderstorm conditions. To reconstruct the atmospheric electric field from the measured radio footprint of the EAS we use an analytic model for the calculation of the radio emission, MGMR3D. In this work we make an extensive comparison between the results of a microscopic model for radio emission, CoREAS, to obtain an improved parametrization for MGMR3D in the presence of atmospheric electric fields, as well as confidence intervals. The approach to extract the electric field structure is applied successfully to an event with a complicated radio footprint measured by LOFAR during thunderstorm conditions. This shows that, with the improved parametrization, MGMR3D can be used to extract the structure of the atmospheric electric field.

astro-ph.HE

Chiral gauge theories and non-abelian analogues of axions

The axion particle may or may not exist, but the axion field can be used, as shown here, in an explicitly local formulation of a chiral U(1) gauge theory with both classical and quantum gauge invariance. Nonabelian analogues of axion fields, which have recently been introduced, can be used, together with their special symmetries, in a similar construction of nonabelian chiral gauge theories. As in known cases, the gauge symmetry is broken and the gauge boson acquires a mass by swallowing the axions which are therefore not physical in this construction.

hep-ph

Characterization of the background spectrum in DAMIC at SNOLAB

We construct the first comprehensive radioactive background model for a dark matter search with charge-coupled devices (CCDs). We leverage the well-characterized depth and energy resolution of the DAMIC at SNOLAB detector and a detailed GEANT4-based particle-transport simulation to model both bulk and surface backgrounds from natural radioactivity down to 50 eV$_{\text{ee}}$. We fit to the energy and depth distributions of the observed ionization events to differentiate and constrain possible background sources, for example, bulk $^{3}$H from silicon cosmogenic activation and surface $^{210}$Pb from radon plate-out. We observe the bulk background rate of the DAMIC at SNOLAB CCDs to be as low as $3.1 \pm 0.6$ counts kg$^{-1}$ day$^{-1}$ keV$_{\text{ee}}^{-1}$, making it the most sensitive silicon dark matter detector. Finally, we discuss the properties of a statistically significant excess of events over the background model with energies below 200 eV$_{\text{ee}}$.

hep-ex

Peccei-Quinn-like symmetries for nonabelian axions

Axions were first introduced in connection with chiral symmetry but are now being looked for mainly as dark matter. In this paper we introduce a nonabelian analogue of axions which can also be potential candidates for dark matter. Their nonabelian symmetries, which are generalizations of the Peccei-Quinn symmetry, are interesting in their own right. Detailed analysis, using fermion measure and zeta function approaches shows that these symmetries are not anomalous.

hep-ph