Searcharxiv⌕ Search

arXiv subjects

P. Moskal

Publications and source records attributed to P. Moskal.

At least 109 records · Page 6Linked to original sources

Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$

The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.

nucl-ex↗

Search for an Isospin I =3 Dibaryon

Various theoretical calculations based on QCD or hadronic interactions predict that in addition to the recently observed dibaryon resonance $d^*(2380)$ with $I(J^P) = 0(3^+)$ there should also exist a dibaryon resonance with mirrored quantum numbers $I(J^P) = 3(0^+)$. We report here on a search for such a $NN$-decoupled state in data on the $pp \to ppπ^+π^+π^-π^-$ reaction. Since no clear-cut evidence has been found, we give upper limits for the production cross section of such a resonance in the mass range 2280 - 2500 MeV.

nucl-ex↗

Feasibility studies of time-like proton electromagnetic form factors at PANDA at FAIR

Simulation results for future measurements of electromagnetic proton form factors at \PANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel $\bar p p \to e^+ e^-$ is studied on the basis of two different but consistent procedures. The suppression of the main background channel, $\textit{i.e.}$ $\bar p p \to π^+ π^-$, is studied. Furthermore, the background versus signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. However, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance.

hep-ex↗

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the o-Ps$\to3γ$ decays with angular and energy resolution equal to $σ(θ) \approx 0.4^{\circ}$ and $σ(E) \approx 4.1$ keV, respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pileups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.

physics.ins-det↗

Measurement of the $ϕ\to π^0 e^+e^-$ transition form factor with the KLOE detector

A measurement of the vector to pseudoscalar conversion decay $ϕ\to π^0 e^+e^-$ with the KLOE experiment is presented. A sample of $\sim 9500$ signal events was selected from a data set of 1.7 fb$^{-1}$ of $e^+e^-$ collisions at $\sqrt{s} \sim m_ϕ$ collected at the DA$Φ$NE $e^+e^-$ collider. These events were used to obtain the first measurement of the transition form factor $| F_{ϕπ^0}(q^2) |$ and a new measurement of the branching ratio of the decay: $\rm{BR}\,(ϕ\to π^0 e^+e^-) = (\,1.35 \pm 0.05^{\,\,+0.05}_{\,\,-0.10}\,) \times 10 ^{-5}$. The result improves significantly on previous measurements and is in agreement with theoretical predictions.

hep-ex↗

Limit on the production of a new vector boson in $\mathrm{e^+ e^-}\rightarrow {\rm U}γ$, U$\rightarrow π^+π^-$ with the KLOE experiment

The recent interest in a light gauge boson in the framework of an extra U(1) symmetry motivates searches in the mass range below 1 GeV. We present a search for such a particle, the dark photon, in ${\rm e^+ e^-}\rightarrow {\rm U}γ$, U$\rightarrow π^+π^-$ based on 28 million $\mathrm{e^+ e^-} \rightarrow π^+ π^-γ$ events collected at DA$Φ$NE by the KLOE experiment. The $π^+ π^-$ production by initial-state radiation compensates for a loss of sensitivity of previous KLOE ${\rm U} \rightarrow \mathrm{e^+ e^-}$, $μ^+μ^-$ searches due to the small branching ratios in the $ρ-ω$ resonance region. We found no evidence for a signal and set a limit at 90\% CL on the mixing strength between the photon and the dark photon, $\varepsilon^2$, in the U mass range between $527$ and $987$~MeV. Above 700 MeV this new limit is more stringent than previous ones.

hep-ex↗

Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2 x 5 configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the 2 x 5 matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of $\approx$ 0.170 ns for 15 cm axial field-of-view (AFOV) and $\approx$ 0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.

physics.ins-det↗

Overview of the software architecture and data flow for the J-PET tomography device

Modern TOF-PET scanner systems require high-speed computing resources for efficient data processing, monitoring and image reconstruction. In this article we present the data flow and software architecture for the novel TOF-PET scanner developed by the J-PET collaboration. We discuss the data acquisition system, reconstruction framework and image reconstruction software. Also, the concept of computing outside hospitals in the remote centers such as Świerk Computing Centre in Poland is presented.

physics.ins-det↗

Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector

This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based on Monte Carlo simulations are presented, which yield a spatial resolution at the level of 2 cm (FWHM) for X and Y and at the level of 1 cm (FWHM) for Z available with the present resolution of J-PET after application of a kinematic fit. Prospects of employment of this method for studying angular correlations of photons in decays of polarized ortho-positronia for the needs of tests of CP and CPT discrete symmetries are also discussed. The new reconstruction method allows for discrimination of background from random three-photon coincidences as well as for application of a novel method for determination of the linear polarization of ortho-positronium atoms, which is also introduced in this work.

physics.ins-det↗

Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner

Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elemental analysis performed using scanning electron microscop (SEM) equipped with energy-dispersive X-ray spectroscop EDS show high purity of the investigated materials.

nucl-ex↗

Sampling FEE and Trigger-less DAQ for the J-PET Scanner

In this paper, we present a complete Data Acquisition System (DAQ) together with the readout mechanisms for the J-PET tomography scanner. In general detector readout chain is constructed out of Front-End Electronics (FEE), measurement devices like Time-to-Digital or Analog-to-Digital Converters (TDCs or ADCs), data collectors and storage. We have developed a system capable for maintaining continuous readout of digitized data without preliminary selection. Such operation mode results in up to 8 Gbps data stream, therefore it is required to introduce a dedicated module for online event building and feature extraction. The Central Controller Module, equipped with Xilinx Zynq SoC and 16 optical transceivers serves as such true real time computing facility. Our solution for the continuous data recording (trigger-less) is a novel approach in such detector systems and assures that most of the information is preserved on the storage for further, high-level processing. Signal discrimination applies an unique method of using LVDS buffers located in the FPGA fabric.

physics.ins-det↗

Scatter fraction of the J-PET tomography scanner

A novel Positron Emission Tomography system, based on plastic scintillators, is being developed by the J-PET collaboration. In this article we present the simulation results of the scatter fraction, representing one of the parameters crucial for background studies defined in the NEMA-NU-2-2012 norm. We elaborate an event selection methods allowing to suppress events in which gamma quanta were scattered in the phantom or underwent the multiple scattering in the detector. The estimated scatter fraction for the single-layer J-PET scanner varies from 37% to 53% depending on the applied energy threshold.

physics.med-ph↗

Design of the SABAT system for underwater detection of dangerous substances

We present status of simulations used to design a novel device for the detection of hazardous substances in the aquatic environment using neutron activation. Unlike the other considered methods based on this technique we propose to use guides for neutron and gamma quanta which speeds up and simplifies identification. First preliminary results show that both the neutron guide and the $γ$ ray guide increase the performance of underwater threats detection.

nucl-ex↗

Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system

The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Being optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolution, it constitutes a multi-purpose detector providing new opportunities for studying the decays of positronium atoms. Positronium is the lightest purely leptonic object decaying into photons. As an atom bound by a central potential it is a parity eigenstate, and as an atom built out of an electron and an anti-electron it is an eigenstate of the charge conjugation operator. Therefore, the positronium is a unique laboratory to study discrete symmetries whose precision is limited in principle by the effects due to the weak interactions expected at the level of (~10$^{-14}$) and photon-photon interactions expected at the level of (~10$^{-9}$). The J-PET detector enables to perform tests of discrete symmetries in the leptonic sector via the determination of the expectation values of the discrete-symmetries-odd operators, which may be constructed from the spin of ortho-positronium atom and the momenta and polarization vectors of photons originating from its annihilation. In this article we present the potential of the J-PET detector to test the C, CP, T and CPT symmetries in the decays of positronium atoms.

nucl-ex↗

Beam profile investigation of the new collimator system for the J-PET detector

Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector which will be used for search for discrete symmetries violations in the decays of positronium atoms and for investigations with positronium atoms in life-sciences and medical diagnostics. In this article we present three methods for determination of the beam profile of collimated annihilation gamma quanta. Precise monitoring of this profile is essential for time and energy calibration of the J-PET detector and for the determination of the library of model signals used in the hit-time and hit-position reconstruction. We have we have shown that usage of two lead bricks with dimensions of 5x10x20 cm^3 enables to form a beam of annihilation quanta with Gaussian profile characterized by 1 mm FWHM. Determination of this characteristic is essential for designing and construction the collimator system for the 24-module J-PET prototype. Simulations of the beam profile for different collimator dimensions were performed. This allowed us to choose optimal collimation system in terms of the beam profile parameters, dimensions and weight of the collimator taking into account the design of the 24 module J-PET detector.

physics.ins-det↗

Upper limits for the production of the eta-mesic Helium in the dd ->3Henpi0 and dd -> 3Heppi- reactions

We performed a search for 4He-eta bound state in dd -> 3Henpi0 and dd -> 3Heppi- reactions with the WASA-at-COSY facility using a ramped beam technique. The measurement was carried out with high statistics and high acceptance. The signature of eta-mesic nuclei was searched for by the measurement of the excitation functions in the vicinity of the eta production threshold for each of the considered channels. We did not observe the narrow structure which could be interpreted as a bound state. The preliminary upper limits of the total cross sections for the bound state production and decay varies from 21 nb to 36 nb for the dd -> 3Henpi0 channel, and from 5 nb to 9 nb for the dd -> 3Heppi- channel for the bound state width ranging from 5 to 50 MeV.

nucl-ex↗

Precision measurement of the $η\toπ^+π^-π^0$ Dalitz plot distribution with the KLOE detector

Using $1.6$ fb$^{-1}$ of $e^+ e^-\toϕ\toηγ$ data collected with the KLOE detector at DA$Φ$NE, the Dalitz plot distribution for the $η\to π^+ π^- π^0$ decay is studied with the world's largest sample of $\sim 4.7 \cdot 10^6$ events. The Dalitz plot density is parametrized as a polynomial expansion up to cubic terms in the normalized dimensionless variables $X$ and $Y$. The experiment is sensitive to all charge conjugation conserving terms of the expansion, including a $gX^2Y$ term. The statistical uncertainty of all parameters is improved by a factor two with respect to earlier measurements.

hep-ex↗

Measurement of the $\vec{n}p \to dπ^0π^0$ Reaction with Polarized Beam in the Region of the $d^*(2380)$ Resonance

We report on a high-statistics measurement of the most basic double pionic fusion reaction $\vec{n}p \to dπ^0π^0$ over the energy region of the $d^*(2380)$ resonance by use of a polarized deuteron beam and observing the double fusion reaction in the quasifree scattering mode. The measurements were performed with the WASA detector setup at COSY. The data reveal substantial analyzing powers and confirm conclusions about the $d^*$ resonance obtained from unpolarized measurements. We also confirm the previous unpolarized data obtained under complementary kinematic conditions.

nucl-ex↗