SearcharxivSearch

arXiv subjects

P. Patteri

Publications and source records attributed to P. Patteri.

At least 19 recordsLinked to original sources

Model-independent extraction of form factors and $|V_{cb}|$ in $\overline{B} \rightarrow D \ell^- \overline{\nu}_\ell$ with hadronic tagging at BaBar

Using the entire BaBar $\Upsilon(4S)$ data set, the first two-dimensional unbinned angular analysis of the semileptonic decay $\overline{B} \rightarrow D \ell^- \overline{\nu}_\ell$ is performed, employing hadronic reconstruction of the tag-side $B$ meson from $\Upsilon(4S)\to B\overline{B}$. Here, $\ell$ denotes the light charged leptons $e$ and $\mu$. A novel data-driven signal-background separation procedure with minimal dependence on simulation is developed. This procedure preserves all multi-dimensional correlations present in the data. The expected $\sin^2\theta_\ell$ dependence of the differential decay rate in the Standard Model is demonstrated, where $\theta_\ell$ is the lepton helicity angle. Including input from the latest lattice QCD calculations and previously available experimental data, the underlying form factors are extracted using both model-independent (BGL) and dependent (CLN) methods. Comparisons with lattice calculations show flavor SU(3) symmetry to be a good approximation in the $B_{(s)}\to D_{(s)}$ sector. Using the BGL results, the CKM matrix element $|V_{cb}|=(41.09\pm 1.16)\times 10^{-3}$ and the Standard Model prediction of the lepton-flavor universality violation variable $\mathcal{R}(D)=0.300\pm 0.004$, are extracted. The value of $|V_{cb}|$ from $\overline{B} \rightarrow D \ell^- \overline{\nu}_\ell$ tends to be higher than that extracted using $\overline{B} \rightarrow D \ell^- \overline{\nu}_\ell$. The Standard Model $\mathcal{R}(D)$ calculation is at a $1.97\sigma$ tension with the latest HFLAV experimental average.

hep-ex

PARSIFAL: a toolkit for triple-GEM parametrized simulation

PARSIFAL (PARametrized SImulation by Farinelli And Lavezzi) is a fast and reliable software tool that reproduces the complete response of a triple-GEM detector to the passage of a charged particle, taking into account the main physical effects. Starting from the detector configuration and the particle information, PARSIFAL reproduces ionization, spatial and temporal diffusion, effect of magnetic field, if present, and GEM amplification to provide the dependable triple-GEM detector response. In the design and optimization stages of this kind of detectors, simulations play an important role. Accurate and robust software programs, such as GARFIELD++, can simulate the transport of electrons and ions in a gas medium and their interaction with the electric field, but they are CPU-time consuming. The necessity to reduce the processing time while maintaining the precision of a full simulation is the main driver of this work. For a given set of geometrical and electrical settings, GARFIELD++ is run once-and-for-all to provide the input parameters for PARSIFAL. Once PARSIFAL is initialized and run, it produces the detector output, including the signal induction and the output of the electronics. The results of the analysis of the simulated data obtained with PARSIFAL are compared with the results of the experimental data collected during a testbeam: some tuning factors are applied to the simulation to improve the agreement. This paper describes the structure of the code and the methodology used to match the output to the experimental data.

physics.ins-det

Search for $B$ Mesogenesis at BABAR

A new mechanism has been proposed to simultaneously explain the presence of dark matter and the matter-antimatter asymmetry in the universe. This scenario predicts exotic $B$ meson decays into a baryon and a dark sector anti-baryon ($ψ_D$) with branching fractions accessible at $B$ factories. We present a search for $B \rightarrow Λψ_D$ decays using data collected by the $BABAR$ experiment at SLAC. This reaction is identified by fully reconstructing the accompanying $B$ meson and requiring the presence of a single $Λ$ baryon in the remaining particles. No significant signal is observed, and bounds on the $B \rightarrow Λψ_D$ branching fraction are derived in the range $0.13 - 5.2\times 10^{-5}$ for $1.0 < m_{ψ_D} < 4.2$ GeV/$c^{2}$. These results set strong constraints on the parameter space allowed by the theory.

hep-ex

Track-based alignment for the BESIII CGEM detector in the cosmic-ray test

The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector operating on the Beijing Electron Positron Collider II (BEPCII). After more than ten year's operation, the efficiency of the inner layers of the Main Drift Chamber (MDC) decreased significantly. To solve this issue, the BESIII collaboration is planning to replace the inner part of the MDC with three layers of Cylindrical triple Gas Electron Multipliers (CGEM). The transverse plane spatial resolution of CGEM is required to be 120 $μ$m or better. To meet this goal, a careful calibration of the detector is necessary to fully exploit the potential of the CGEM detector. In all the calibrations, the detector alignment plays an important role to improve the detector precision. The track-based alignment for the CGEM detector with the Millepede algorithm is implemented to reduce the uncertainties of the hit position measurement. Using the cosmic-ray data taken in 2020 with the two layers setup, the displacement and rotation of the outer layer with respect to the inner layer is determined by a simultaneous fit applied to more than 160000 tracks. A good alignment precision has been achieved that guarantees the design request could be satisfied in the future. A further alignment is going to be performed using the combined information of tracks from cosmic-ray and collisions after the CGEM is installed into the BESIII detector.

hep-ex

The CGEM-IT readout chain

An innovative Cylindrical Gas Electron Multiplier (CGEM) detector is under construction for the upgrade of the inner tracker of the BESIII experiment. A novel system has been worked out for the readout of the CGEM detector, including a new ASIC, dubbed TIGER -Torino Integrated GEM Electronics for Readout, designed for the amplification and digitization of the CGEM output signals. The data output by TIGER are collected and processed by a first FPGA-based module, GEM Read Out Card, in charge of configuration and control of the front-end ASICs. A second FPGA-based module, named GEM Data Concentrator, builds the trigger selected event packets containing the data and stores them via the main BESIII data acquisition system. The design of the electronics chain, including the power and signal distribution, will be presented together with its performance.

physics.ins-det

Measurements of the Absolute Branching Fractions of $B^\pm \to K^\pm X_{c\bar c}$

A study of the two body decays $B^\pm\rightarrow X_{c\bar c}K^\pm$, where X$_{c\bar c}$ refers to one charmonium state, is reported by BaBar collaboration using a data sample of 424 fb$^{-1}$. The absolute determination of branching fractions for these decays are significantly improved compared to previous BaBaR measurements. Evidence is found for the decay $B^+\rightarrow X(3872)K^+$ at the $3σ$ level. The absolute branching fraction ${\cal B}(B^+\rightarrow X(3872)K^+) = (2.1\pm0.6({\rm stat})\pm0.3({\rm syst}))\times 10^{-4}$ is measured for the first time. It follows that ${\cal B}(X(3872)\rightarrow J/ψπ^+π^-)=(4.1\pm1.3)\%$, supporting the hypothesis of a molecular component for this resonance.

hep-ex

Precision measurement of the ${\cal B}(Υ(3S)\toτ^+τ^-)/{\cal B}(Υ(3S)\toμ^+μ^-)$ ratio

We report on a precision measurement of the ratio ${\cal R}_{τμ}^{Υ(3S)} = {\cal B}(Υ(3S)\toτ^+τ^-)/{\cal B}(Υ(3S)\toμ^+μ^-)$ using data collected with the BaBar detector at the SLAC PEP-II $e^+e^-$ collider. The measurement is based on a 28 fb$^{-1}$ data sample collected at a center-of-mass energy of 10.355 GeV corresponding to a sample of 122 million $Υ(3S)$ mesons. The ratio is measured to be ${\cal R}_{τμ}^{Υ(3S)} = 0.966 \pm 0.008_\mathrm{stat} \pm 0.014_\mathrm{syst}$ and is in agreement with the Standard Model prediction of 0.9948 within 2 standard deviations. The uncertainty in ${\cal R}_{τμ}^{Υ(3S)}$ is almost an order of magnitude smaller than the only previous measurement.

hep-ex

Search for lepton-flavor violating decays $D^{0}\rightarrow X^{0}e^{\pm}μ^{\mp}$

We present a search for seven lepton-flavor-violating neutral charm decays of the type $D^{0}\rightarrow X^{0} e^{\pm} μ^{\mp}$, where $X^{0}$ represents a $π^{0}$, $K^{0}_{\rm S}$, $\bar{K^{*0}}$, $ρ^{0}$, $ϕ$, $ω$, or $η$ meson. The analysis is based on $468$ fb$^{-1}$ of $e^+e^-$ annihilation data collected at or close to the $Υ(4S)$ resonance with the BaBar detector at the SLAC National Accelerator Laboratory. No significant signals are observed, and we establish 90\% confidence level upper limits on the branching fractions in the range $(5.0 - 22.5)\times 10^{-7}$. The limits are between one and two orders of magnitude more stringent than previous measurements.

hep-ex

Time performance of a triple-GEM detector at high rate

Gaseous detectors are used in high energy physics as trackers or, more generally, as devices for the measurement of the particle position. For this reason, they must provide high spatial resolution and they have to be able to operate in regions of intense radiation, i.e. around the interaction point of collider machines. Among these, Micro Pattern Gaseous Detectors (MPGD) are the latest frontier and allow to overcome many limitations of the pre-existing detectors, such as the radiation tolerance and the rate capability. The gas Electron Multiplier (GEM) is a MPGD that exploits an intense electric field in a reduced amplification region in order to prevent discharges. Several amplification stages, like in a triple-GEM, allow to increase the detector gain and to reduce the discharge probability. Reconstruction techniques such as charge centroid (CC) and micro-Time Projection Chamber ($\upmu$TPC) are used to perform the position measurement. From literature triple-GEMs show a stable behaviour up to $10^8\,$Hz/cm$^2$. A testbeam with four planar triple-GEMs has been performed at the Mainz Microtron (MAMI) facility and their performance was evaluated in different beam conditions. In this article a focus on the time performance for the $\upmu$TPC clusterization is given and a new measurement of the triple-GEM limits at high rate will be presented.

physics.ins-det

Search for rare or forbidden decays of the $D^{0}$ meson

We present a search for nine lepton-number-violating and three lepton-flavor-violating neutral charm decays of the type $D^0\rightarrow h^{\prime -} h^{-}\ell^{\prime +} \ell^{+}$ and $D^0\rightarrow h^{\prime -} h^{+}\ell^{\prime\pm} \ell^{\mp}$, where $h$ and $h^{\prime}$ represent a $K$ or $π$ meson and $\ell$ and $\ell^{\prime}$ an electron or muon. The analysis is based on $468$ fb$^{-1}$ of $e^+e^-$ annihilation data collected at or close to the $Y(4S)$ resonance with the BaBar detector at the SLAC National Accelerator Laboratory. No significant signal is observed for any of the twelve modes and we establish 90% confidence level upper limits on the branching fractions in the range $(1.0 - 30.6)\times 10^{-7}$. The limits are between one and three orders of magnitude times more stringent than previous measurements.

hep-ex

Search for $B^- \to Λ\bar p ν\barν$ with the BABAR experiment

We search for the rare flavor-changing neutral current process $B^- \to Λ{\overline p} ν{\overlineν}$ using data from the BABAR experiment. A total of 424 fb$^{-1}$ of $e^+e^-$ collision data collected at the center-of-mass energy of the $Υ$(4S) resonance is used in this study, corresponding to a sample of ${(471 \pm 3) \times 10^{6}}$ $B\overline{B}$ pairs. Signal $B^- \to Λ{\overline p} ν{\overlineν}$ candidates are identified by first fully reconstructing a $B^+$ decay in one of many possible exclusive decays to hadronic final states, then examining detector activity that is not associated with this reconstructed $B^+$ decay for evidence of a signal $B^- \to Λ{\overline p} ν{\overlineν}$ decay. The data yield is found to be consistent with the expected background contribution under a null signal hypothesis, resulting in an upper limit of ${{\cal B} (B^- \to Λ{\overline p} ν{\overlineν}) < 3.0\times 10^{-5}}$ at the $90\%$ confidence level.

hep-ex

Triple GEM performance in magnetic field

Performance of triple GEM prototypes in strong magnetic field has been evaluated bymeans of a muon beam at the H4 line of the SPS test area at CERN. Data have been reconstructedand analyzed offline with two reconstruction methods: the charge centroid and the micro-Time-Projection-Chamber exploiting the charge and the time measurement respectively. A combinationof the two reconstruction methods is capable to guarantee a spatial resolution better than 150μmin magnetic field up to a 1 T.

physics.ins-det

GRAAL: Gem Reconstruction And Analysis Library

MPGD are the new frontier in gas trackers. Among this kind of devices, theGEM chambers are widely used. The experimental signals acquired with the detector mustobviously be reconstructed and analysed. In this contribution, a new offline software to performreconstruction, alignment and analysis on the data collected with APV-25 and TIGER ASICswill be presented. GRAAL (Gem Reconstruction And Analysis Library) is able to measurethe performance of a MPGD detector with a strip segmented anode (presently). The code isdivided in three parts: reconstruction, where the hits are digitized and clusterized; tracking,where a procedure fits the points from the tracking system and uses that information to align thechamber with rotations and shifts; analysis, where the performance is evaluated (e.g. efficiency,spatial resolution,etc.). The user must set the geometry of the setup and then the programreturns automatically the analysis results, taking care of different conditions of gas mixture,electric field, magnetic field, geometries, strip orientation, dead strip, misalignment and manyothers.

physics.ins-det

A fast and parametric digitization for triple-GEM detectors

Triple-GEM detectors are a well known technology in high energy physics. In order to have a complete understanding of their behavior, in parallel with on beam testing, a Monte Carlo code has to be developed to simulate their response to the passage of particles. The software must take into account all the physical processes involved from the primary ionization up to the signal formation, e.g. the avalanche multiplication and the effect of the diffusion on the electrons. In the case of gas detectors, existing software such as Garfield already perform a very detailed simulation but are CPU time consuming. A description of a reliable but faster simulation is presented here: it uses a parametric description of the variables of interest obtained by suitable preliminary Garfield simulations and tuned to the test beam data. It can reproduce the real values of the charge measured by the strip, needed to reconstruct the position with the Charge Centroid method. In addition, particular attention was put to the simulation of the timing information, which permits to apply also the micro-Time Projection Chamber position reconstruction, for the first time on a triple-GEM. A comparison between simulation and experimental values of some sentinel variables in different conditions of magnetic field, high voltage settings and incident angle will be shown.

physics.ins-det

A model to explain angular distributions of $J/ψ$ and $ψ(2S)$ decays into $Λ\overlineΛ$ and $Σ^0\overlineΣ^0$

BESIII data show a particular angular distribution for the decay of the $J/ψ$ and $ψ(2S)$ mesons into the hyperons $Λ\overlineΛ$ and $Σ^0\overlineΣ^0$. More in details the angular distribution of the decay $ψ(2S) \to Σ^0\overlineΣ^0$ exhibits an opposite trend with respect to that of the other three channels: $J/ψ\to Λ\overlineΛ$, $J/ψ\to Σ^0\overlineΣ^0$ and $ψ(2S) \to Λ\overlineΛ$. We define a model to explain the origin of this phenomenon.

hep-ph

A Cylindrical GEM Inner Tracker for the BESIII experiment at IHEP

The Beijing Electron Spectrometer III (BESIII) is a multipurpose detector that collects data provided by the collision in the Beijing Electron Positron Collider II (BEPCII), hosted at the Institute of High Energy Physics of Beijing. Since the beginning of its operation, BESIII has collected the world largest sample of J/ψ and ψ(2s). Due to the increase of the luminosity up to its nominal value of 10^33 cm-2 s-1 and aging effect, the MDC decreases its efficiency in the first layers up to 35% with respect to the value in 2014. Since BESIII has to take data up to 2022 with the chance to continue up to 2027, the Italian collaboration proposed to replace the inner part of the MDC with three independent layers of Cylindrical triple-GEM (CGEM). The CGEM-IT project will deploy several new features and innovation with respect the other current GEM based detector: the μTPC and analog readout, with time and charge measurements will allow to reach the 130 μm spatial resolution in 1 T magnetic field requested by the BESIII collaboration. In this proceeding, an update of the status of the project will be presented, with a particular focus on the results with planar and cylindrical prototypes with test beams data. These results are beyond the state of the art for GEM technology in magnetic field.

physics.ins-det

Innovative design and construction technique for the Cylindrical GEM detector for the BESIII experiment

Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the particles and to exploit the its properties to construct a large area detector, such as the new IT for BESIII. The state of the art in the GEM production allow to create very large area GEM foils (up to 50x100 cm2) and thanks to the small thickness of these foil is it possible to shape it to the desired form: a Cylindrical Gas Electron Multiplier (CGEM) is then proposed. The innovative construction technique based on Rohacell, a PMI foam, will give solidity to cathode and anode with a very low impact on material budget. The entire detector is sustained by permaglass rings glued at the edges. These rings are use to assembly the CGEM together with a dedicated Vertical Insertion System and moreover there is placed the On-Detector electronic. The anode has been improved w.r.t. the state of the art through a jagged readout that minimize the inter-strip capacitance. The mechanical challenge of this detector requires a precision of the entire geometry within few hundreds of microns in the whole area. In this presentation will be presented an overview of the construction technique and the validation of this technique through the realization of a CGEM and its first tests. These activities are performed within the framework of the BESIIICGEM Project (645664), funded by the European Commission in the action H2020-RISE-MSCA-2014.

physics.ins-det

Performance of the micro-TPC Reconstruction for GEM Detectors at High Rate

Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors, as drift chambers and microstrips, reducing the discharge rate and increasing the radiation tolerance. Among these, one of the most commonly used is the Gas Electron Multiplier. Commonly deployed as fast timing detectors and triggers, due to their fast response, high rate capability and high radiation hardness, they can also be used as trackers. The center of gravity readout technique allows to overcome the limit of the digital pads, whose spatial resolution is constrained by the pitch size. The presence of a high external magnetic field can distort the electronic cloud and affect the spatial resolution. The micro-TPC reconstruction method allows to reconstruct the three dimensional particle position as in a traditional Time Projection Chamber, but within a drift gap of a few millimeters. This method brings these detectors into a new perspective for what concerns the spatial resolution in strong magnetic field. In this report, the basis of this new technique will be shown and it will be compared to the traditional center of gravity. The results of a series of test beam performed with 10 x 10 cm2 planar prototypes in magnetic field will also be presented. This is one of the first implementations of this technique for GEM detectors in magnetic field and allows to reach unprecedented performance for gas detectors, up to a limit of 120 micron at 1T, one of the world's best results for MPGDs in strong magnetic field. The micro-TPC reconstruction has been recently tested at very high rates in a test beam at the MAMI facility; preliminary results of the test will be presented.

physics.ins-det