SearcharxivSearch

arXiv subjects

P. Paulitsch

Publications and source records attributed to P. Paulitsch.

2 recordsLinked to original sources

Charge Collection and Electrical Characterization of Neutron Irradiated Silicon Pad Detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$μ\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

physics.ins-det

Imaging with protons at MedAustron

Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sources of inaccuracy in alculation of the stopping power (SP). A more precise method to acquire the SP is to directly use high energy protons (or other ions such as carbon) and perform proton computed tomography (pCT). With this method, the ions are tracked prior to entering and after leaving the patient and finally their residual energy is measured at the very end. Therefore, an ion imaging demonstrator, comprising a tracking telescope made from double-sided silicon strip detectors and a range telescope as a residual energy detector, was set up. First measurements with this setup were performed at beam tests at MedAustron, a center for ion therapy and research in \mbox{Wiener Neustadt}, \mbox{Austria}. The facility provides three rooms for cancer treatment with proton beams as well as one which is dedicated to non-clinical research. This contribution describes the principle of ion imaging with proton beams in general as well as the design of the experimental setup. Moreover, first results from simulations and recent beam tests as well as ideas for future developments will be presented.

physics.ins-det