SearcharxivSearch

arXiv subjects

P. Perrin

Publications and source records attributed to P. Perrin.

3 recordsLinked to original sources

Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K

Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from radioactive impurities in or near the acrylic can emit Cherenkov radiation in the ultraviolet (UV) spectra range. If acrylic fluoresces in the visible range due to this UV light, it could be a source of background in experiments where the main signal is visible scintillation light, or UV scintillation light that is absorbed and re-emitted at visible wavelengths by a wavelength shifter. Some of these experiments operate at low temperature. The fluorescence of these materials could change with temperature so we have studied the fluorescence of the acrylic used in the DEAP-3600 experiment down to a temperature of 4 K, and compared it to the common wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene (TPB). The light yield and wavelength spectra of these materials were characterized by exciting the sample with 285 nm UV light which acted as a proxy for Cherenkov light in the detector. Spectral measurements indicate at least part of the fluorescence of the acrylic is due to additives. Time-resolved measurements show the light yields of our acrylic sample, TPB sample, and the relative light between both samples, all increase when cooling down. At room temperature, the light yield of our acrylic sample relative to the TPB sample is 0.3 %, while it reaches 0.5 % at 4 K. The main fluorescence time constant of the acrylic is less than a few nanoseconds.

physics.ins-det

Growth mechanism of polymer membranes obtained by H-bonding across immiscible liquid interfaces

Complexation of polymers at liquid interfaces is an emerging technique to produce all-liquid printable and self-healing devices and membranes. It is crucial to control the assembly process but the mechanisms at play remain unclear. Using two different reflectometric methods, we investigate the spontaneous growth of H-bonded PPO-PMAA membranes at a flat liquid-liquid interface. We find that the membrane thickness h grows with time t as h~t^(1/2), which is reminiscent of a diffusion-limited process. However, counter-intuitively, we observe that this process is faster as the PPO molar mass increases. We are able to rationalize these results with a model which considers the diffusion of the PPO chains within the growing membrane. The architecture of the latter is described as a gel-like porous network, with a pore size much smaller than the radius of the diffusing PPO chains, thus inducing entropic barriers that hinder the diffusion process. From the comparison between the experimental data and the result of the model, we extract some key piece of information about the microscopic structure of the membrane. This study opens the route toward the rational design of self-assembled membranes and capsules with optimal properties.

cond-mat.soft

Probing the adsorption/desorption of amphiphilic polymers at the air-water interface during large interfacial deformations

Hydrophobically modified polymers are good candidates for the stabilization of liquid interfaces thanks to the high anchoring energy of the hydrophobic parts. In this article we probe the interfacial anchoring of a series of home-made hydrophobically modified polymers of controlled degree of grafting by studying their behavior upon large area dilations and compressions. By comparing the measured interfacial tension to the one that we expect in the case of a constant number of adsorbed monomers, we are able to deduce whether desorption or adsorption occurs during area variations. We find that the polymer chains with the longest hydrophobic grafts desorb for larger compressions than the polymers with the shortest grafts, because of their larger desorption energy. Furthermore, we observe more desorption for polymers with the highest grafting densities. We attribute this counter intuitive result to the fact that for high grafting densities, the length of the polymer loops is shorter, hence the elastic penalty upon compression is larger for these layers, leading to a faster desorption. The dilatation experiments reveal that the number of adsorbed anchors remains constant in the case of chains with low grafting density while chains with the highest degree of grafting seem to show some degree of adsorption during the dilatation. Therefore for these highly grafted chains there may be unadsorbed grafts remaining in the vicinity of the interface, which may adsorb quickly to the interface upon dilatation.

physics.app-ph