SearcharxivSearch

arXiv subjects

P. Plischke

Publications and source records attributed to P. Plischke.

7 recordsLinked to original sources

High-resolution spectroscopy of gaseous $^\mathrm{83m}$Kr conversion electrons with the KATRIN experiment

In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous $^\mathrm{83m}$Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The results obtained in this calibration measurement represent a major commissioning milestone for the upcoming direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the full KATRIN beamline. The KATRIN main spectrometer's excellent energy resolution of ~ 1 eV made it possible to determine the narrow K-32 and L$_3$-32 conversion electron line widths with an unprecedented precision of ~ 1 %.

physics.ins-det

Technical design and commissioning of the KATRIN large-volume air coil system

The KATRIN experiment is a next-generation direct neutrino mass experiment with a sensitivity of 0.2 eV (90% C.L.) to the effective mass of the electron neutrino. It measures the tritium $β$-decay spectrum close to its endpoint with a spectrometer based on the MAC-E filter technique. The $β$-decay electrons are guided by a magnetic field that operates in the mT range in the central spectrometer volume; it is fine-tuned by a large-volume air coil system surrounding the spectrometer vessel. The purpose of the system is to provide optimal transmission properties for signal electrons and to achieve efficient magnetic shielding against background. In this paper we describe the technical design of the air coil system, including its mechanical and electrical properties. We outline the importance of its versatile operation modes in background investigation and suppression techniques. We compare magnetic field measurements in the inner spectrometer volume during system commissioning with corresponding simulations, which allows to verify the system's functionality in fine-tuning the magnetic field configuration. This is of major importance for a successful neutrino mass measurement at KATRIN.

physics.ins-det

Commissioning of the vacuum system of the KATRIN Main Spectrometer

The KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer (Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m^3, and a complex inner electrode system with about 120000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300°C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.

physics.ins-det

Improved limits on nuebar emission from mu+ decay

We investigated mu+ decays at rest produced at the ISIS beam stop target. Lepton flavor (LF) conservation has been tested by searching for \nueb via the detection reaction p(\nueb,e+)n. No \nueb signal from LF violating mu+ decays was identified. We extract upper limits of the branching ratio for the LF violating decay mu+ -> e+ \nueb νcompared to the Standard Model (SM) mu+ -> e+ nue numub decay: BR < 0.9(1.7)x10^{-3} (90%CL) depending on the spectral distribution of \nueb characterized by the Michel parameter rho=0.75 (0.0). These results improve earlier limits by one order of magnitude and restrict extensions of the SM in which \nueb emission from mu+ decay is allowed with considerable strength. The decay \mupdeb as source for the \nueb signal observed in the LSND experiment can be excluded.

hep-ex

Upper limits for neutrino oscillations muon-antineutrino to electron-antineutrino from muon decay at rest

The KARMEN experiment at the spallation neutron source ISIS used \numub from \mup--decay at rest in the search for neutrino oscillations \numubnueb in the appearance mode, with p(\nueb,e+)n as detection reaction of \nueb. In total, 15 candidates fulfill all conditions for the \nueb signature, in agreement with the background expectation of 15.8+-0.5 events, yielding no indication for oscillations. A single event based likelihood analysis leads to upper limits on the oscillation parameters: sin^2(2theta)<1.7x10e-3 for Dm^2>100 eV^2 and Dm^2<0.055 eV^2 for sin^2(2theta)=1 at 90% confidence. Thus, KARMEN does not confirm the LSND experiment and restricts significantly its favored parameter region for \numubnueb.

hep-ex

Measurement of the energy spectrum of ν_e from muon decay and implications for the Lorentz structure of the weak interaction

The KARMEN experiment uses the reaction 12C(ν_e,e-)12N to measure the energy distribution of ν_e emitted in muon decay at rest. The ν_e analog ω_l of the famous Michel parameter ρhas been derived from a maximum-likelihood analysis of events near the kinematic end point, E_max. The result, ω_l = (2.7^{+3.8}_{-3.3}\pm 3.1) * 10^{-2}, is in good agreement with the standard model prediction ω_l= 0. We deduce a 90% confidence upper limit of ω_l <= 0.113, which corresponds to a limit of |g^S_RL + 2 g^T_RL| <= 0.78 on the interference term between scalar and tensor coupling constants.

hep-ex

KARMEN Limits on nu_e -> nu_tau Oscillations in 2-neutrino and 3-neutrino Mixing Schemes

The 56 tonne high resolution liquid scintillation calorimeter KARMEN at the beam stop neutrino source ISIS has been used to search for neutrino oscillations in the disappearance channel nu_e->x. The nu_e emitted in mu+ decay at rest are detected with spectroscopic quality via the exclusive charged current reaction 12-C(nu_e,e-)12-N_g.s. almost free of background. Analysis of the spectral shape of e- from the nu_e induced reaction as well as a measurement of the absolute nu_e flux allow to investigate oscillations of the type nu_e->nu_tau and nu_e->nu_mu . The flux independent ratio R(CC/NC) of charged current events 12-C(nu_e,e-)12-N_g.s. to neutral current events 12-C(nu,nu')12-C* provides additional information in the oscillation channel nu_e->x . All three analysis methods show no evidence for oscillations. For the nu_e->nu_tau channel 90%CL limits of sin^2(2t)<0.338 for dm^2>100eV^2 and dm^2<0.77eV^2 for maximal mixing in a simple 2 flavor oscillation formalism are derived. A complete 3 flavor analysis of the experimental data from five years of measurement with respect to nu_e<->nu_tau and nu_e<->nu_mu mixing is presented.

hep-ex