Searcharxiv⌕ Search

arXiv subjects

P. Povinec

Publications and source records attributed to P. Povinec.

At least 37 records · Page 2Linked to original sources

Measurement of double-$β$ decay of $^{150}$Nd to the 0$^+_1$ excited state of $^{150}$Sm in NEMO-3

The NEMO-3 results for the double-$β$ decay of $^{150}$Nd to the 0$^+_1$ and 2$^+_1$ excited states of $^{150}$Sm are reported. The data recorded during 5.25 yr with 36.6 g of the isotope $^{150}$Nd are used in the analysis. For the first time, the signal of the $2νββ$ transition to the 0$^+_1$ excited state is detected with a statistical significance exceeding 5$σ$. The half-life is measured to be $T_{1/2}^{2νββ}(0^+_1) = \left[ 1.11 ^{+0.19}_{-0.14} \,\left(\mbox{stat}\right) ^{+0.17}_{-0.15}\, \left(\mbox{syst}\right) \right] \times10^{20}\,\mbox{yr}$. The limits are set on the $2νββ$ decay to the 2$^+_1$ level and on the $0νββ$ decay to the 0$^+_1$ and 2$^+_1$ levels of $^{150}$Sm.

nucl-ex↗

Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment

New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration sources. This requires new calibration sources with sub-keV energies. When searching for nuclear recoil signals, the calibration source should ideally cause mono-energetic nuclear recoils in the relevant energy range. Recently, a new calibration method based on the radiative neutron capture on $^{182}$W with subsequent de-excitation via single $γ$-emission leading to a nuclear recoil peak at 112 eV was proposed. The CRESST-III dark matter search operated several CaWO$_{4}$-based detector modules with detection thresholds below 100 eV in the past years. We report the observation of a peak around the expected energy of 112 eV in the data of three different detector modules recorded while irradiated with neutrons from different AmBe calibration sources. We compare the properties of the observed peaks with Geant-4 simulations and assess the prospects of using this for the energy calibration of CRESST-III detectors.

physics.ins-det↗

Results on sub-GeV Dark Matter from a 10 eV Threshold CRESST-III Silicon Detector

We present limits on the spin-independent interaction cross section of dark matter particles with silicon nuclei, derived from data taken with a cryogenic calorimeter with 0.35 g target mass operated in the CRESST-III experiment. A baseline nuclear recoil energy resolution of $(1.36\pm 0.05)$ eV$_{\text{nr}}$, currently the lowest reported for macroscopic particle detectors, and a corresponding energy threshold of $(10.0\pm 0.2)$ eV$_{\text{nr}}$ have been achieved, improving the sensitivity to light dark matter particles with masses below 160 MeV/c$^2$ by a factor of up to 20 compared to previous results. We characterize the observed low energy excess, and we exclude noise triggers and radioactive contaminations on the crystal surfaces as dominant contributions.

astro-ph.CO↗

Secular Equilibrium Assessment in a $\mathrm{CaWO}_4$ Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation

CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-based normalisation results using a recently developed spectral template normalisation method based on Bayesian likelihood. We find deviations from SE; further investigations are necessary to determine their origin.

physics.ins-det↗

Towards an automated data cleaning with deep learning in CRESST

The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a careful cleaning process to avoid wrongly reconstructed recoil energies caused by pile-up and read-out artefacts. We frame this process as a time series classification task and propose to automate it with neural networks. With a data set of over one million labeled records from 68 detectors, recorded between 2013 and 2019 by CRESST, we test the capability of four commonly used neural network architectures to learn the data cleaning task. Our best performing model achieves a balanced accuracy of 0.932 on our test set. We show on an exemplary detector that about half of the wrongly predicted events are in fact wrongly labeled events, and a large share of the remaining ones have a context-dependent ground truth. We furthermore evaluate the recall and selectivity of our classifiers with simulated data. The results confirm that the trained classifiers are well suited for the data cleaning task.

physics.ins-det↗

Latest observations on the low energy excess in CRESST-III

The CRESST experiment observes an unexplained excess of events at low energies. In the current CRESST-III data-taking campaign we are operating detector modules with different designs to narrow down the possible explanations. In this work, we show first observations of the ongoing measurement, focusing on the comparison of time, energy and temperature dependence of the excess in several detectors. These exclude dark matter, radioactive backgrounds and intrinsic sources related to the crystal bulk as a major contribution.

astro-ph.CO↗

Testing spin-dependent dark matter interactions with lithium aluminate targets in CRESST-III

In the past decades, numerous experiments have emerged to unveil the nature of dark matter, one of the most discussed open questions in modern particle physics. Among them, the CRESST experiment, located at the Laboratori Nazionali del Gran Sasso, operates scintillating crystals as cryogenic phonon detectors. In this work, we present first results from the operation of two detector modules which both have 10.46 g LiAlO$_2$ targets in CRESST-III. The lithium contents in the crystal are $^6$Li, with an odd number of protons and neutrons, and $^7$Li, with an odd number of protons. By considering both isotopes of lithium and $^{27}$Al, we set the currently strongest cross section upper limits on spin-dependent interaction of dark matter with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$.

astro-ph.CO↗

Probing spin-dependent dark matter interactions with $^6$Li

CRESST is one of the most prominent direct detection experiments for dark matter particles with sub-GeV/c$^2$ mass. One of the advantages of the CRESST experiment is the possibility to include a large variety of nuclides in the target material used to probe dark matter interactions. In this work, we discuss in particular the interactions of dark matter particles with protons and neutrons of $^{6}$Li. This is now possible thanks to new calculations on nuclear matrix elements of this specific isotope of Li. To show the potential of using this particular nuclide for probing dark matter interactions, we used the data collected previously by a CRESST prototype based on LiAlO$_2$ and operated in an above ground test-facility at Max-Planck-Institut für Physik in Munich, Germany. In particular, the inclusion of $^{6}$Li in the limit calculation drastically improves the result obtained for spin-dependent interactions with neutrons in the whole mass range. The improvement is significant, greater than two order of magnitude for dark matter masses below 1 GeV/c$^2$, compared to the limit previously published with the same data.

physics.ins-det↗

Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO

The SuperNEMO experiment will search for neutrinoless double-beta decay ($0νββ$), and study the Standard-Model double-beta decay process ($2νββ$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($ββ$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly. The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.

physics.ins-det↗

Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on spin-dependent dark matter interactions with ordinary matter

In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut für Kristallzüchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50 GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.

physics.ins-det↗

Search for Periodic Modulations of the Rate of Double-Beta Decay of $^{100}$Mo in the NEMO-3 Detector

Double-beta decays of $^{100}$Mo from the 6.0195-year exposure of a 6.914 kg high-purity sample were recorded by the NEMO-3 experiment that searched for neutrinoless double-beta decays. These ultra-rare transitions to $^{100}$Ru have a half-life of approximately $7\times10^{18}$ years, and have been used to conduct the first ever search for periodic variations of this decay mode. The Lomb-Scargle periodogram technique, and its error-weighted extension, were employed to look for periodic modulations of the half-life. Monte Carlo modeling was used to study the modulation sensitivity of the data over a broad range of amplitudes and frequencies. Data show no evidence of modulations with amplitude greater than 2.5% in the frequency range of $0.33225\,{\rm y^{-1}}$ to $365.25\,{\rm y^{-1}}$.

nucl-ex↗

Search for the double-beta decay of 82Se to the excited states of 82Kr with NEMO-3

The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82Se; 0+gs -> 0+1) > 1.3 1021 y at 90% CL has been set. Concerning the 0nbb decay to the 0+1 state, a limit for this decay has been obtained with T0n 1/2(82Se; 0+g s -> 0+1) > 2.3 1022 y at 90% CL, independently from the 2nbb decay process. These results are obtained for the first time with a tracko-calo detector, reconstructing every particle in the final state.

physics.ins-det↗

Geant4-based electromagnetic background model for the CRESST dark matter experiment

The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in $\mathrm{CaWO_4}$ crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to $(68 \pm 16)\,\mathrm{\%}$ of the electromagnetic background in the energy range between $1\,\mathrm{keV}$ and $40\,\mathrm{keV}$.

astro-ph.IM↗

Detailed studies of $^{100}$Mo two-neutrino double beta decay in NEMO-3

The full data set of the NEMO-3 experiment has been used to measure the half-life of the two-neutrino double beta decay of $^{100}$Mo to the ground state of $^{100}$Ru, $T_{1/2} = \left[ 6.81 \pm 0.01\,\left(\mbox{stat}\right) ^{+0.38}_{-0.40}\,\left(\mbox{syst}\right) \right] \times10^{18}$ y. The two-electron energy sum, single electron energy spectra and distribution of the angle between the electrons are presented with an unprecedented statistics of $5\times10^5$ events and a signal-to-background ratio of ~80. Clear evidence for the Single State Dominance model is found for this nuclear transition. Limits on Majoron emitting neutrinoless double beta decay modes with spectral indices of n=2,3,7, as well as constraints on Lorentz invariance violation and on the bosonic neutrino contribution to the two-neutrino double beta decay mode are obtained.

nucl-ex↗

Final results on $^\textbf{82}$Se double beta decay to the ground state of $^\textbf{82}$Kr from the NEMO-3 experiment

Using data from the NEMO-3 experiment, we have measured the two-neutrino double beta decay ($2νββ$) half-life of $^{82}$Se as $T_{1/2}^{2ν} = \left[ 9.39 \pm 0.17\,\left(\mbox{stat}\right) \pm 0.58\,\left(\mbox{syst}\right)\right] \times 10^{19}$ y under the single-state dominance hypothesis for this nuclear transition. The corresponding nuclear matrix element is $\left|M^{2ν}\right| = 0.0498 \pm 0.0016$. In addition, a search for neutrinoless double beta decay ($0νββ$) using 0.93 kg of $^{82}$Se observed for a total of 5.25 y has been conducted and no evidence for a signal has been found. The resulting half-life limit of $T_{1/2}^{0ν} > 2.5 \times 10^{23} \,\mbox{y} \,(90\%\,\mbox{C.L.})$ for the light neutrino exchange mechanism leads to a constraint on the effective Majorana neutrino mass of $\langle m_ν \rangle < \left(1.2 - 3.0\right) \,\mbox{eV}$, where the range reflects $0νββ$ nuclear matrix element values from different calculations. Furthermore, constraints on lepton number violating parameters for other $0νββ$ mechanisms, such as right-handed currents, majoron emission and R-parity violating supersymmetry modes have been set.

hep-ex↗

Calorimeter development for the SuperNEMO double beta decay experiment

SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, $Δ$E/E, around 3%/$sqrt(E)$(MeV) $σ$, or 7%/$sqrt(E)$(MeV) FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. We describe the R\&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.

physics.ins-det↗

The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials

The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been developed to measure radiopurity of the selenium double $β$-decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and validation of the BiPo-3 measurement with a calibrated aluminium foil is discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of the first enriched $^{82}$Se foils of the double $β$-decay SuperNEMO experiment are reported. The sensitivity of the BiPo-3 detector for the measurement of the SuperNEMO $^{82}$Se foils is $\mathcal{A}$($^{208}$Tl) $<2$ $μ$Bq/kg (90\% C.L.) and $\mathcal{A}$($^{214}$Bi) $<140$ $μ$Bq/kg (90\% C.L.) after 6 months of measurement.

physics.ins-det↗

Search for neutrinoless quadruple-$β$ decay of $^{150}$Nd with the NEMO-3 detector

We report the results of a first experimental search for lepton number violation by four units in the neutrinoless quadruple-$β$ decay of $^{150}$Nd using a total exposure of $0.19$ kg$\cdot$y recorded with the NEMO-3 detector at the Modane Underground Laboratory (LSM). We find no evidence of this decay and set lower limits on the half-life in the range $T_{1/2}>(1.1-3.2)\times10^{21}$ y at the $90\%$ CL, depending on the model used for the kinematic distributions of the emitted electrons.

hep-ex↗