SearcharxivSearch

arXiv subjects

P. Robmann

Publications and source records attributed to P. Robmann.

25 records · Page 2Linked to original sources

New Precise Measurement of the Pion Weak Form Factors in the Pi+ -> e+ nu gamma Decay

We have measured the $π^+\to {\rm e}^+νγ$ branching ratio over a wide region of phase space, based on a total of 65,460 events acquired using the PIBETA detector. Minimum-$χ^2$ fits to the measured $(E_{e^+},E_γ)$ energy distributions result in the weak form factor value of $F_A=0.0119(1)$ with a fixed value of $F_V=0.0259$. An unconstrained fit yields $F_V=0.0258(17)$ and $F_A=0.0117(17)$. In addition, we have measured $a=0.10(6)$ for the dependence of $F_V$ on $q^2$, the ${\rm e}^{+}ν$ pair invariant mass squared, parametrized as $F_V(q^2)=F_V(0)(1+a\cdot q^2)$. The branching ratio for the kinematic region $E_γ> 10 $MeV and $θ_{{\rm e^+}γ} > 40^\circ $ is measured to be $B^{\rm exp}=73.86(54) \times 10^{-8}$. Earlier deviations we reported in the high-$E_γ$/low-$E_{{\rm e}^+}$ kinematic region are resolved, and we find full compatibility with CVC and standard $V$$-$$A$ calculations without a tensor term. We also derive new values for the pion polarizability, $α_E = \rm 2.78(10) \times 10^{-4} fm^3$, and neutral pion lifetime, $τ_{π0} = (8.5 \pm 1.1) \times 10^{-17} $s.

hep-ex

Mechanical Design and Material Budget of the CMS Barrel Pixel Detector

The Compact Muon Solenoid experiment at the Large Hadron Collider at CERN includes a silicon pixel detector as its innermost component. Its main task is the precise reconstruction of charged particles close to the primary interaction vertex. This paper gives an overview of the mechanical requirements and design choices for the barrel pixel detector. The distribution of material in the detector as well as its description in the Monte Carlo simulation are discussed in detail.

physics.ins-det

Precise Measurement of pi+ -> e+ nu Branching Ratio

The PEN Collaboration is conducting a new measurement of the pi+ -> e+ nu branching ratio at the Paul Scherrer Institute, with the goal uncertainty of delta B/B(pie2)=5E-4 or lower. At present, the combined accuracy of all published pie2 decay measurements lags behind the theoretical calculation by a factor of 40. In this contribution we report on the PEN detector configuration and its performance during two development runs done in 2007 and 2008.

hep-ex

CMS Barrel Pixel Detector Overview

The pixel detector is the innermost tracking device of the CMS experiment at the LHC. It is built from two independent sub devices, the pixel barrel and the end disks. The barrel consists of three concentric layers around the beam pipe with mean radii of 4.4, 7.3 and 10.2 cm. There are two end disks on each side of the interaction point at 34.5 cm and 46.5 cm. This article gives an overview of the pixel barrel detector, its mechanical support structure, electronics components, services and its expected performance.

physics.ins-det

Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the Inner Tracking System of HERA-B

The results of five years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about 20 * 20 cm2 each. The detector is based on microstrip gas counters (MSGCs) with diamond like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step. Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar-DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO2 showed no serious aging effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000.

hep-ex

An Improved Limit on the Rate Of Decay K+ -> pi+ mu+ e-

The experiment E865 at BNL places an upper limit on the branching ratio for the decay K+ -> pi+ mu+ e- of 3.9x10^-11 (90% C.L.). Along with with other results this yields a combined upper limit on this branching ratio of 2.8x10^-11. A new upper limit on the branching ratio for pi0 -> mu+ e- of 3.8x10^-10 (90% C.L.) is also established. The experiment and analysis are described.

hep-ex