SearcharxivSearch

arXiv subjects

P. Sala

Publications and source records attributed to P. Sala.

At least 19 recordsLinked to original sources

Modeling Light Signals Using Data from the First Pulsed Neutron Source Program at the DUNE Vertical Drift ColdBox Test Facility at CERN Neutrino Platform

In this paper, we present a first quantitative test of detected light signals produced in a pulsed neutron source run in a small vertical drift LArTPC at the CERN neutrino platform ColdBox test facility. The ColdBox cryostat, detectors, neutron sources, and particle interactions are modeled and simulated using Fluka. A good agreement is found in the detected number of photoelectrons, with values below 650 photoelectrons in both data and simulation, for all four X-ARAPUCA photodetectors on the cathode in the LArTPC. A time constant is also fitted from the neutron-beam-off light signal spectrum and found consistent between data and MC. Several important systematic effects are discussed and serve as guides for future runs at larger LArTPCs.

hep-ex

Design and Implementation of the Cosmic Ray Tagger System for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system ($\sim$1100 m$^2$), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

hep-ex

Search for Inelastic Boosted Dark Matter with the ICARUS Detector at the Gran Sasso Underground National Laboratory

We present the result of a search for inelastic boosted dark matter using the data corresponding to an exposure of 0.13 kton$\cdot$year, collected by the ICARUS T-600 detector during its 2012--2013 operational period at the INFN Gran Sasso Underground National Laboratory. The benchmark boosted dark matter model features a multi-particle dark sector with a U(1)$'$ gauge boson, the dark photon. The kinetic mixing of the dark photon with the Standard Model photon allows for a portal between the dark sector and the visible sector. The inelastic boosted dark matter interaction occurs when a dark matter particle inelastically scatters with an electron in the ICARUS detector, producing an outgoing, heavier dark sector state which subsequently decays back down to the dark matter particle, emitting a dark photon. The dark photon subsequently couples to a Standard Model photon through kinetic mixing. The Standard Model photon then converts to an electron-positron pair in the detector. This interaction process provides a distinct experimental signature which consists of a recoil electron from the primary interaction and an associated electron-positron pair from the secondary vertex. After analyzing 4,134 triggered events, the search results in zero observed events. Exclusion limits are set in the dark photon mass and coupling ($m_X, \epsilon$) parameter space for several selected optimal boosted dark matter mass sets.

hep-ex

Low-Energy Physics in Neutrino LArTPCs

In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. 2) Low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. 3) BSM signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of BSM scenarios accessible in LArTPC-based searches. 4) Neutrino interaction cross sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood. Improved theory and experimental measurements are needed. Pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for experimentally improving this understanding. 5) There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. 6) Novel ideas for future LArTPC technology that enhance low-energy capabilities should be explored. These include novel charge enhancement and readout systems, enhanced photon detection, low radioactivity argon, and xenon doping. 7) Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways.

physics.ins-det

The addition of temporal neighborhood makes the logic of prefixes and sub-intervals EXPSPACE-complete

A classic result by Stockmeyer gives a non-elementary lower bound to the emptiness problem for star-free generalized regular expressions. This result is intimately connected to the satisfiability problem for interval temporal logic, notably for formulas that make use of the so-called chop operator. Such an operator can indeed be interpreted as the inverse of the concatenation operation on regular languages, and this correspondence enables reductions between non-emptiness of star-free generalized regular expressions and satisfiability of formulas of the interval temporal logic of chop under the homogeneity assumption. In this paper, we study the complexity of the satisfiability problem for suitable weakenings of the chop interval temporal logic, that can be equivalently viewed as fragments of Halpern and Shoham interval logic. We first consider the logic $\mathsf{BD}_{hom}$ featuring modalities $B$, for \emph{begins}, corresponding to the prefix relation on pairs of intervals, and $D$, for \emph{during}, corresponding to the infix relation. The homogeneous models of $\mathsf{BD}_{hom}$ naturally correspond to languages defined by restricted forms of regular expressions, that use union, complementation, and the inverses of the prefix and infix relations. Such a fragment has been recently shown to be PSPACE-complete . In this paper, we study the extension $\mathsf{BD}_{hom}$ with the temporal neighborhood modality $A$ (corresponding to the Allen relation \emph{Meets}), and prove that it increases both its expressiveness and complexity. In particular, we show that the resulting logic $\mathsf{BDA}_{hom}$ is EXPSPACE-complete.

cs.LO

Coded masks for imaging of neutrino events

The capture of scintillation light emitted by liquid Argon and Xenon under molecular excitations by charged particles is still a challenging task. Here we present a first attempt to design a device able to grab sufficiently high luminosity in order to reconstruct the path of ionizing particles. This preliminary study is based on the use of masks to encode the light signal combined with single-photon detectors. In this respect, the proposed system is able to detect tracks over focal distances of about tens of centimeters. From numerical simulations it emerges that it is possible to successfully decode and recognize signals, even complex, with a relatively limited number of acquisition channels. Such innovative technique can be very fruitful in a new generation of detectors devoted to neutrino physics and dark matter search. Indeed the introduction of coded masks combined with SiPM detectors is proposed for a liquid-Argon target in the Near Detector of the DUNE experiment.

physics.ins-det

Design and implementation of the new scintillation light detection system of ICARUS T600

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab(USA), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementationof the new scintillation light detection system of ICARUS T600 is described.

physics.ins-det

A measurement of the group velocity of scintillation light in liquid argon

The propagation velocity of scintillation light in liquid argon $v_{g}$ at $\lambda \sim 128$~nm wavelength, has been measured for the first time in a dedicated experimental setup at CERN.\\ The obtained result $\frac{1}{v_{g}} = 7.46 \pm 0.08$~ns/m , is then used to derive the value of the refractive index (n) and the Rayleigh scattering length ($\mathcal{L}$) for liquid argon in the VUV region. For $\lambda = 128$~nm we found $n= 1.358 \pm 0.003$ and $\mathcal{L}= 99.1 \pm 2.3$~cm. The measured values are of interest for a variety of experiments searching for rare events like neutrino and dark matter interactions. The derived quantities also represent key information for theoretical models describing the propagation of scintillation light in liquid argon.

physics.ins-det

Cryogenic SiPM arrays for the DUNE photon detection system

In this paper we report on the characterization of SiPM tiles developed for the R & D on the DUNE Photon Detection System. The tiles were produced by Fondazione Bruno Kessler (FBK) employing NUV-HD-SF SiPMs. Special emphasis is given on cryo-reliability of the sensors, i.e. the stability of electric and mechanical properties after thermal cycles at room and 77K temperature. The characterization includes the determination of the I-V curve, a high sensitivity measurement of Dark Count Rate at different overvoltages, and correlated noise. The single p.e. sensitivity is measured as a function of the number of sensors connected to a single electronic channel, after amplification at 77K using a dedicated cold amplifier.

physics.ins-det

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. A detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

physics.ins-det

Summary of the NuSTEC Workshop on Shallow- and Deep-Inelastic Scattering

The NuSTEC workshop (https://indico.cern.ch/event/727283) held at L'Aquila in October 2018 was devoted to neutrino-nucleus scattering in the kinematic region where hadronic systems with invariant masses above the $\Delta(1232)$ resonance are produced: the so-called shallow- and deep-inelastic scattering regime. Not only is the physics in this kinematic region quite intriguing, it is also important for current and future oscillation experiments with accelerator and atmospheric neutrinos. For the benefit of the community, links to the presentations are accompanied by annotations from the speakers.

hep-ph

Gaussian states for the variational study of (1+1)-dimensional lattice gauge models

We introduce a variational ansatz based on Gaussian states for (1+1)-dimensional lattice gauge models. To this end we identify a set of unitary transformations which decouple the gauge degrees of freedom from the matter fields. Using our ansatz, we study static aspects as well as real-time dynamics of string breaking in two (1+1)-dimensional theories, namely QED and two-color QCD. We show that our ansatz captures the relevant features and is in excellent agreement with data from numerical calculations with tensor networks.

hep-lat

Test and characterization of 400 Hamamatsu R5912-MOD photomultiplier tubes for the ICARUS T600 detector

ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile neutrino signal. The detector employs 360 photomultiplier tubes, Hamamatsu model R5912-MOD, suitable for cryogenic applications. A total of 400 PMTs were procured from Hamamatsu and tested at room temperature to evaluate the performance of the devices and their compliance to detect the liquid argon scintillation light in the T600 detector. Furthermore 60 units were also characterized at cryogenic temperature, in liquid argon bath, to evaluate any parameter variation which could affect the scintillation light detection. All the tested PMTs were found to comply with the requirements of ICARUS T600 and a subset of 360 specimens was selected for the final installation in the detector.

physics.ins-det

Analysis of time-profiles with in-beam PET monitoring in charged particle therapy

Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability of MC predictions of space and time (decay rate) profiles shortly after irradiation, and we show how the decay rates can give an indication about the elements of which the phantom is made up. Methods and Materials: Various phantoms were irradiated in clinical and near-clinical conditions at the Cyclotron Centre of the Bronowice proton therapy centre. PET data were acquired with a planar 16x16 cm$^2$ PET system. MC simulations of particle interactions and photon propagation in the phantoms were performed using the FLUKA code. The analysis included a comparison between experimental data and MC simulations of space and time profiles, as well as a fitting procedure to obtain the various isotope contributions in the phantoms. Results and conclusions: There was a good agreement between data and MC predictions in 1-dimensional space and decay rate distributions. The fractions of $^{11}$C, $^{15}$O and $^{10}$C that were obtained by fitting the decay rates with multiple simple exponentials generally agreed well with the MC expectations. We found a small excess of $^{10}$C in data compared to what was predicted in MC, which was clear especially in the PE phantom.

physics.med-ph

Variational study of U(1) and SU(2) lattice gauge theories with Gaussian states in 1+1 dimensions

We introduce a method to investigate the static and dynamic properties of both Abelian and non-Abelian lattice gauge models in 1+1 dimensions. Specifically, we identify a set of transformations that disentangle different degrees of freedom, and apply a simple Gaussian variational ansatz to the resulting Hamiltonian. To demonstrate the suitability of the method, we analyze both static and dynamic aspects of string breaking for the U(1) and SU(2) gauge models. We benchmark our results against tensor network simulations and observe excellent agreement, although the number of variational parameters in the Gaussian ansatz is much smaller.

hep-lat

Some conclusive considerations on the comparison of the ICARUS nu_mu to nu_e oscillation search with the MiniBooNE low-energy event excess

A sensitive search for anomalous LSND-like nu_mu to nu_e oscillations has been performed by the ICARUS Collaboration exposing the T600 LAr-TPC to the CERN to Gran Sasso (CNGS) neutrino beam. The result is compatible with the absence of additional anomalous contributions giving a limit to oscillation probability of 3.4E-3 and 7.6E-3 at 90% and 99% confidence levels respectively showing a tension between these new limits and the low-energy event excess (200 < E_nu QE < 475 MeV) reported by MiniBooNE Collaboration. A more detailed comparison of the ICARUS data with the MiniBooNE low-energy excess has been performed, including the energy resolution as obtained from the official MiniBooNE data release. As a result the previously reported tension is confirmed at 90% C.L., suggesting an unexplained nature or an otherwise instrumental effect for the MiniBooNE low energy event excess

hep-ph

Experimental observation of an extremely high electron lifetime with the ICARUS-T600 LAr-TPC

The ICARUS T600 detector, the largest liquid Argon Time Projection Chamber (LAr-TPC) realized after many years of RD activities, was installed and successfully operated for 3 years at the INFN Gran Sasso underground Laboratory. One of the most important issues was the need of an extremely low residual electronegative impurity content in the liquid Argon, in order to transport the free electrons created by the ionizing particles with a very small attenuation along the drift path. The solutions adopted for the Argon re-circulation and purification systems have permitted to reach impressive results in terms of Argon purity and a free electron lifetime exceeding 15 ms, corresponding to about 20 parts per trillion of equivalent O2 contamination, a milestone for any future project involving LAr-TPC's and the development of higher detector mass scales.

physics.ins-det

First tests for an online treatment monitoring system with in-beam PET for proton therapy

PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype DoPET. PMMA phantoms were irradiated with mono-energetic proton beams and clinical treatment plans, and PET data were acquired during and shortly after proton irradiation. We created 1-D profiles of the beta+ activity along the proton beam-axis, and evaluated the difference between the proximal rise and the distal fall-off position of the activity distribution. A good agreement with FLUKA Monte Carlo predictions was obtained. We also assessed the system response when the PMMA phantom contained an air cavity. The system was able to detect these cavities quickly after irradiation.

physics.med-ph