Searcharxiv⌕ Search

arXiv subjects

P. Salabura

Publications and source records attributed to P. Salabura.

At least 73 records · Page 4Linked to original sources

Test of a single module of the J-PET scanner based on plastic scintillators

Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.

physics.ins-det↗

Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 ps

physics.ins-det↗

Medium effects in proton-induced $K^{0}$ production at 3.5 GeV

We present the analysis of the inclusive $K^{0}$ production in p+p and p+Nb collisions measured with the HADES detector at a beam kinetic energy of 3.5 GeV. Data are compared to the GiBUU transport model. The data suggest the presence of a repulsive momentum-dependent kaon potential as predicted by the Chiral Perturbation Theory (ChPT). For the kaon at rest and at normal nuclear density, the ChPT potential amounts to $\approx 35$ MeV. A detailed tuning of the kaon production cross sections implemented in the model has been carried out to reproduce the experimental data measured in p+p collisions. The uncertainties in the parameters of the model were examined with respect to the sensitivity of the experimental results from p+Nb collisions to the in-medium kaon potential.

nucl-ex↗

Lambda hyperon production and polarization in collisions of p(3.5 GeV) + Nb

Results on $Λ$ hyperon production are reported for collisions of p(3.5 GeV) + Nb, studied with the High Acceptance Di-Electron Spectrometer (HADES) at SIS18 at GSI Helmholtzzentrum for Heavy-Ion Research, Darmstadt. The transverse mass distributions in rapidity bins are well described by Boltzmann shapes with a maximum inverse slope parameter of about $90\,$MeV at a rapidity of $y=1.0$, i.e. slightly below the center-of-mass rapidity for nucleon-nucleon collisions, $y_{cm}=1.12$. The rapidity density decreases monotonically with increasing rapidity within a rapidity window ranging from 0.3 to 1.3. The $Λ$ phase-space distribution is compared with results of other experiments and with predictions of two transport approaches which are available publicly. None of the present versions of the employed models is able to fully reproduce the experimental distributions, i.e. in absolute yield and in shape. Presumably, this finding results from an insufficient modelling in the transport models of the elementary processes being relevant for $Λ$ production, rescattering and absorption. The present high-statistics data allow for a genuine two-dimensional investigation as a function of phase space of the self-analyzing $Λ$ polarization in the weak decay $Λ\rightarrow p π^-$. Finite negative values of the polarization in the order of $5-20\,\%$ are observed over the entire phase space studied. The absolute value of the polarization increases almost linearly with increasing transverse momentum for $p_t>300\,$MeV/c and increases with decreasing rapidity for $y < 0.8$.

nucl-ex↗

Baryon resonance production and dielectron decays in proton-proton collisions at 3.5 GeV

We report on baryon resonance production and decay in proton-proton collisions at a kinetic energy of $3.5$ GeV based on data measured with HADES. The exclusive channels $pp \rightarrow npπ^{+}$ and $pp \rightarrow ppπ^{0}$ as well as $pp \rightarrow ppe^{+}e^{-}$ are studied simultaneously for the first time. The invariant masses and angular distributions of the pion-nucleon systems were studied and compared to simulations based on a resonance model ansatz assuming saturation of the pion production by an incoherent sum of baryonic resonances (R) with masses $<2~$ GeV/$c^2$. A very good description of the one-pion production is achieved allowing for an estimate of individual baryon-resonance production-cross-sections which are used as input to calculate the dielectron yields from $R\rightarrow pe^+e^-$ decays. Two models of the resonance decays into dielectrons are examined assuming a point-like $RN γ^*$ coupling and the dominance of the $ρ$ meson. The results of model calculations are compared to data from the exclusive $ppe^{+}e^{-}$ channel by means of the dielectron and $pe^+e^-$ invariant mass distributions.

nucl-ex↗

Associate K^0 production in p+p collisions at 3.5 GeV: The role of Delta(1232)++

An exclusive analysis of the 4-body final states $\mathrm{Λ+ p + π^{+} + K^{0}}$ and $\mathrm{Σ^{0} + p + π^{+} + K^{0}}$ measured with HADES for p+p collisions at a beam kinetic energy of 3.5 GeV is presented. The analysis uses various phase space variables, such as missing mass and invariant mass distributions, in the four particle event selection (p, $π^+$, $π^+$, $π^-$) to find cross sections of the different production channels, contributions of the intermediate resonances $\mathrm{Δ^{++}}$ and $\mathrm{Σ(1385)^{+}}$ and corresponding angular distributions. A dominant resonant production is seen, where the reaction $\mathrm{Λ+ Δ^{++} + K^{0}}$ has an about ten times higher cross section ($\mathrm{29.45\pm0.08^{+1.67}_{-1.46}\pm2.06\,μb}$) than the analogous non-resonant reaction ($\mathrm{2.57\pm0.02^{+0.21}_{-1.98}\pm0.18\,μb}$). A similar result is obtained in the corresponding $Σ^{0}$ channels with $\mathrm{9.26\pm0.05^{+1.41}_{-0.31}\pm0.65\,\ mu b}$ in the resonant and $\mathrm{1.35\pm0.02^{+0.10}_{-1.35}\pm0.09\,μb}$ in the non-resonant reactions.

nucl-ex↗

A novel method for calibration and monitoring of time synchronization of TOF-PET scanners by means of cosmic rays

All of the present methods for calibration and monitoring of TOF-PET scanner detectors utilize radioactive isotopes such as e.g. $^{22}$Na or $^{68}$Ge, which are placed or rotate inside the scanner. In this article we describe a novel method based on the cosmic rays application to the PET calibration and monitoring methods. The concept allows to overcome many of the drawbacks of the present methods and it is well suited for newly developed TOF-PET scanners with a large longitudinal field of view. The method enables also monitoring of the quality of the scintillator materials and in general allows for the continuous quality assurance of the PET detector performance.

physics.ins-det↗

J-PET analysis framework for the prototype TOF-PET detector

Novel TOF-PET scanner solutions demand, apart from the state of the art detectors, software for fast processing of the gathered data, monitoring of the whole scanner and reconstruction of the PET image. In this article we present an analysis framework for the novel STRIP-PET scanner developed by the J-PET collaboration in the Institute of Physics of the Jagiellonian University. This software is based on the ROOT package used in many particle physics experiments.

physics.ins-det↗

Determination of the map of efficiency of the J-PET detector with the GATE package

A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.

physics.ins-det↗

Database and data structure for the novel TOF-PET detector developed for J-PET project

The complexity of the hardware and the amount of data collected during the PET imaging process require application of modern methods of efficient data organization and processing. In this article we will discuss the data structures and the flow of collected data from the novel TOF-PET medical scanner which is being developed at the Jagiellonian University. The developed data format reflects: registration process of the gamma quanta emitted from positron-electron annihilation, Front-End Electronic (FEE) structure and required input information for the image reconstruction. In addition, the system database fulfills possible demands of the evolving J-PET project.

physics.ins-det↗

Computing support for advanced medical data analysis and imaging

We discuss computing issues for data analysis and image reconstruction of PET-TOF medical scanner or other medical scanning devices producing large volumes of data. Service architecture based on the grid and cloud concepts for distributed processing is proposed and critically discussed.

physics.comp-ph↗

Calibration of photomultipliers gain used in the J-PET detector

Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we describe single photoelectron method used for photomultipliers calibration applied for J-PET scanner, a novel PET detector being developed at the Jagiellonian University. Description of calibration method, an example of calibration curve and gain of few R4998 Hamamatsu photomultipliers are presented.

physics.ins-det↗

Simulations of gamma quanta scattering in a single module of the J-PET detector

This article describes simulations of scattering of annihilation gamma quanta in a strip of plastic scintillator. Such strips constitute basic detection modules in a newly proposed Positron Emission Tomography which utilizes plastic scintillators instead of inorganic crystals. An algorithm simulating chain of Compton scatterings was elaborated and series of simulations have been conducted for the scintillator strip with the cross section of 5 mm x 19 mm. Obtained results indicate that secondary interactions occur only in the case of about 8% of events and out of them only 25$\%$ take place in the distance larger than 0.5 cm from the primary interaction. It was also established that light signals produced at primary and secondary interactions overlap with the delay which distribution is characterized by FWHM of about 40 ps.

physics.ins-det↗

Application of WLS strips for position determination in Strip PET tomograph based on plastic scintillators

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly proposed PET detectors based on plastic scintillators is presented. The method enables to reduce parallax errors in reconstruction of images which occurs in the presently used Positron Emission Tomography scanners.

physics.ins-det↗

A novel method based solely on FPGA units enabling measurement of time and charge of analog signals in Positron Emission Tomography

This article presents a novel technique for precise measurement of time and charge based solely on FPGA (Field Programmable Gate Array) device and few satellite discrete electronic components used in Positron Emission Tomography (PET). Described approach simplifies electronic circuits, reduces the power consumption, lowers costs, merges front-end electronics with digital electronics and also makes more compact final design. Furthermore, it allows to measure time when analog signals cross a reference voltage at different threshold levels with a very high precision of $\sim$ 10ps (rms) and thus enables sampling of signals in a voltage domain.

physics.ins-det↗

An upper limit on hypertriton production in collisions of Ar(1.76 AGeV)+KCl

A high-statistic data sample of Ar(1.76 AGeV)+KCl events recorded with HADES is used to search for a hypertriton signal. An upper production limit per centrality-triggered event of $1.04$ x $10^{-3}$ on the $3σ$ level is derived. Comparing this value with the number of successfully reconstructed $Λ$ hyperons allows to determine an upper limit on the ratio $N_{_Λ^3H}/N_Λ$, which is confronted with statistical and coalescence-type model calculations.

nucl-ex↗

Searching a Dark Photon with HADES

We present a search for the e+e- decay of a hypothetical dark photon, also names U vector boson, in inclusive dielectron spectra measured by HADES in the p (3.5 GeV) + p, Nb reactions, as well as the Ar (1.756 GeV/u) + KCl reaction. An upper limit on the kinetic mixing parameter squared epsilon^{2} at 90% CL has been obtained for the mass range M(U) = 0.02 - 0.55 GeV/c2 and is compared with the present world data set. For masses 0.03 - 0.1 GeV/c^2, the limit has been lowered with respect to previous results, allowing now to exclude a large part of the parameter region favoured by the muon g-2 anomaly. Furthermore, an improved upper limit on the branching ratio of 2.3 * 10^{-6} has been set on the helicity-suppressed direct decay of the eta meson, eta-> e+e-, at 90% CL.

hep-ex↗

System Response Kernel Calculation for List-mode Reconstruction in Strip PET Detector

Reconstruction of the image in Positron Emission Tomographs (PET) requires the knowledge of the system response kernel which describes the contribution of each pixel (voxel) to each tube of response (TOR). This is especially important in list-mode reconstruction systems, where an efficient analytical approximation of such function is required. In this contribution, we present a derivation of the system response kernel for a novel 2D strip PET.

physics.med-ph↗