SearcharxivSearch

arXiv subjects

P. Sanchez-Lucas

Publications and source records attributed to P. Sanchez-Lucas.

7 recordsLinked to original sources

Cryogenic characterization of FBK NUV-HD-Cryo 3T SiPM sensors for the DUNE photon detection system

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment based in the USA and composed of a Near Detector (ND) complex at Fermi National Laboratory (FNAL), and a Far Detector (FD) complex located at the Sanford Underground Research Facility (SURF) $\sim$1300\,km distant. DUNE will study neutrino oscillations looking for unresolved issues of the Standard Model of particle physics (SM) such as CP violation in the leptonic sector, neutrino mass ordering and others, starting from the early 2030s. The FD, with a mass of $\sim$17\,kt, that will exploit both ionization and scintillation signals to detect neutrino interactions with Argon. Scintillating photons in LAr will be detected by the photon detection system (PDS) based on light collectors coupled to Silicon Photomultipliers (SiPMs). During a test campaign, different laboratories of the collaboration performed an investigation of the best SiPM candidates that fulfill the DUNE FD requirements. We identified two models of SiPM, produced by Hamamatsu Photonics K.K. (HPK) and Fondazione Bruno Kessler (FBK), respectively. In this paper, we focus on the FBK selected model showing its main features. We will describe the characterization protocol, the results at both room and cryogenic temperatures and the photon detection efficiency measurements.

physics.ins-det

Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator

There is a compelling physics case for a large, xenon-based underground detector devoted to dark matter and other rare-event searches. A two-phase time projection chamber as inner detector allows for a good energy resolution, a three-dimensional position determination of the interaction site and particle discrimination. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demonstrator for the DARWIN experiment at the University of Zurich. Here we present first results from a several-months run with 343 kg of xenon and electron drift lifetime and transport measurements with a 53 cm tall purity monitor immersed in the cryogenic liquid. After 88 days of continuous purification, the electron lifetime reached a value of 664(23) microseconds. We measured the drift velocity of electrons for electric fields in the range (25--75) V/cm, and found values consistent with previous measurements. We also calculated the longitudinal diffusion constant of the electron cloud in the same field range, and compared with previous data, as well as with predictions from an empirical model.

physics.ins-det

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

physics.ins-det

The first dual-phase xenon TPC equipped with silicon photomultipliers and characterisation with $^{37}$Ar

For the first time, a small dual-phase (liquid/gas) xenon time projection chamber was equipped with a top array of silicon photomultipliers for light and charge readout. Here we describe the instrument in detail, as well as the data processing and the event position reconstruction algorithms. We obtain a spatial resolution of ~1.5 mm in the horizontal plane. To characterise the detector performance, we show calibration data with internal $^{83\text{m}}$Kr and $^{37}$Ar sources, and we detail the production of the latter as well as its introduction into the system. We finally compare the observed light and charge yields down to electronic recoil energies of 2.82 keV to predictions based on NEST v2.0.

astro-ph.IM

Design and construction of Xenoscope -- a full-scale vertical demonstrator for the DARWIN observatory

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and other rare interactions. It will operate a 50 t liquid xenon detector, with 40 t in the time projection chamber (TPC). To inform the final detector design and technical choices, a series of technological questions must first be addressed. Here we describe a full-scale demonstrator in the vertical dimension, Xenoscope, with the main goal of achieving electron drift over a 2.6 m distance, which is the scale of the DARWIN TPC. We have designed and constructed the facility infrastructure, including the cryostat, cryogenic and purification systems, the xenon storage and recuperation system, as well as the slow control system. We have also designed a xenon purity monitor and the TPC, with the fabrication of the former nearly complete. In a first commissioning run of the facility without an inner detector, we demonstrated the nominal operational reach of Xenoscope and benchmarked the components of the cryogenic and slow control systems, demonstrating reliable and continuous operation of all subsystems over 40 days. The infrastructure is thus ready for the integration of the purity monitor, followed by the TPC. Further applications of the facility include R&D on the high voltage feedthrough for DARWIN, measurements of electron cloud diffusion, as well as measurements of optical properties of liquid xenon. In the future, Xenoscope will be available as a test platform for the DARWIN collaboration to characterise new detector technologies.

physics.ins-det

Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.

physics.ins-det

Deep learning techniques applied to the physics of extensive air showers

Deep neural networks are a powerful technique that have found ample applications in several branches of Physics. In this work, we apply machine learning algorithms to a specific problem of Cosmic Ray Physics: the estimation of the muon content of extensive air showers when measured at the ground. As a working case, we explore the performance of a deep neural network applied to the signals recorded by the water-Cherenkov detectors of the Surface Detector Array of the Pierre Auger Observatory. We apply deep learning architectures to large sets of simulated data. The inner structure of the neural network is optimized through the use of genetic algorithms. To obtain a prediction of the recorded muon signal in each individual detector, we train neural networks with a mixed sample of light, intermediate and heavy nuclei. When true and predicted signals are compared at detector level, the primary values of the Pearson correlation coefficients are above 95\%. The relative errors of the predicted muon signals are below 10\% and do not depend on the event energy, zenith angle, total signal size, distance range or the hadronic model used to generate the events.

astro-ph.IM