SearcharxivSearch

arXiv subjects

P. Schury

Publications and source records attributed to P. Schury.

At least 19 recordsLinked to original sources

High-Precision Mass Measurements of Proton-Rich Rh, Pd, Cd isotopes in the vicinity of 100Sn and Impact on X-Ray Burst and Supernova Nucleosynthesis

Using the ZeroDegree multi-reflection time-of-flight mass spectrograph of the CRISMASS project at RIKEN Radioactive Isotope Beam Factory, we performed high-precision mass measurements of proton-rich nuclei near the doubly magic nucleus 100Sn, achieving uncertainties on the order of 10 keV. The masses of 91Rh, 92Pd, and 96Cd were determined for the first time with high precision, and the accuracy of several additional masses was substantially improved. Incorporating the new data into X-ray burst simulations significantly reduces the abundance uncertainties in the $A$ = 90-100 region, shifting the reaction flow toward $A$ = 90 production and suppressing the synthesis of heavier nuclei. Further investigation of the $\nu p$-process indicates that 99Rh plays a significant role in the reaction flow within the mass region studied. These high-precision mass measurements refine the mass surface near 100Sn and provide critical constraints on models of proton-rich nucleosynthesis.

nucl-ex

New Ground State in ${}^{149}$La Removes Two-Neutron-Separation-Energy Anomaly in Lanthanum Isotopes

Nuclear mass is a key indicator of how the nuclear shell structure evolves. The recent mass measurement study of neutron-rich lanthanum isotopes [A. Jaries, $et~al$., Phys. Rev. Lett. {\bf 134}, 042501(2025)] reveals the presence of a distinct prominence in their two-neutron separation energies. However, its presence has been called into question based on the results of another mass determination [B. Liu, Ph.D. thesis, University of Notre Dame (2025)]. In this letter, we report an effort to clarify these contradictory results through the use of the simultaneous mass-lifetime measurement of the neutron-rich lanthanum isotope ${}^{149}$La using a multi-reflection time-of-flight mass spectrograph combined with a $\beta$-TOF detector. The peak corresponding to a $\beta$-decaying state was observed in the time-of-flight spectra at a position of $221(6)~{\rm keV/c^2}$ lighter than the reported ${}^{149}$La mass in A. Jaries, $et~al$., but our measured result is in excellent agreement with the mass value reported in B. Liu. We have concluded that this peak is the ground state of ${}^{149}$La. With this, the previously reported distinct prominence in the two-neutron separation energies disappears, while a new kink structure, similar to that in the cerium isotopes, appears. Comparison with theoretical models suggests that a nuclear shape transition from octupole deformation to another type of deformation occurs around $N=91$ and is likely the cause of this kink structure.

nucl-ex

Precision mass measurements around ${}^{84}$Mo rule out ZrNb cycle formation in the rapid proton-capture process at type I X-ray bursts

The rapid proton-capture ($rp$-) process is one of the primary, explosive thermonuclear burning processes that drive type I X-ray bursts. A possible termination of the $rp$-process at around ${}^{84}$Mo was previously suggested by the formation of a ZrNb cycle. We report here precision mass measurements at around ${}^{84}$Mo, which have concluded the possibility of the cycle. The experiment was conducted using the multi-reflection time-of-flight spectrograph at RIKEN RI Beam Factory, and the masses of ${}^{79}$Y, ${}^{83}$Nb, ${}^{84}$Mo, ${}^{88}$Ru, and an isomer in ${}^{78}$Y were measured. For ${}^{84}$Mo, and ${}^{88}$Ru, and the isomeric state of ${}^{78}$Y, their masses are experimentally determined for the first time with uncertainties of $\delta m \approx 20~{\rm keV/c^2}$. The mass precision of ${}^{79}$Y and ${}^{83}$Nb is improved to $13~{\rm keV/c^2}$ and $9.6~{\rm keV/c^2}$, respectively. The new $\alpha$-separation energy of ${}^{84}$Mo, 1.434(83) MeV, unambiguously rules out the possibility of forming the ZrNb cycle. The X-ray burst simulation with the new masses shows that our measurements effectively remove the large final abundance uncertainties in the $A=80-90$ mass region. The new mass values improve the prediction power for the composition of the nuclear ashes in X-ray bursts.

nucl-ex

Direct observation of $\beta$ and $\gamma$ decay from a high-spin long-lived isomer in $^{187}$Ta

$^{187}$Ta ($Z=73$, $N=114$) is located in the neutron-rich $A \approx 190$ region where a prolate-to-oblate shape transition via triaxial softness is predicted to take place. A preceding work on the $K^{\pi} = (25/2^-)$ isomer and a rotational band to which the isomer decays carried out by the same collaboration revealed that axial symmetry is slightly violated in this nucleus. This paper focuses on a higher-lying isomer, which was previously identified at 2933(14) keV by mass measurements with the Experimental Storage Ring at GSI. The isomer of interest has been populated by a multi-nucleon transfer reaction with a $^{136}$Xe primary beam incident on a natural tungsten target, using the KEK Isotope Separation System at RIKEN. New experimental findings obtained in the present paper include the internal and external $\beta$-decay branches from the high-spin isomer and a revised half-life of 136(24) s. The evaluated hindrances for $K$-forbidden transitions put constraints on the spin-parity assignment, which can be interpreted as being ascribed to a prolate shape with a five-quasiparticle configuration by model calculations.

nucl-ex

Particle Identification at VAMOS++ with Machine Learning Techniques

Multi-nucleon transfer reaction between 136Xe beam and 198Pt target was performed using the VAMOS++ spectrometer at GANIL to study the structure of n-rich nuclei around N=126. Unambiguous charge state identification was obtained by combining two supervised machine learning methods, deep neural network (DNN) and positional correction using a gradient-boosting decision tree (GBDT). The new method reduced the complexity of the kinetic energy calibration and outperformed the conventional method, improving the charge state resolution by 8%

physics.ins-det

A new study of the $N=32$ and $N=34$ shell gap for Ti and V by the first high-precision MRTOF mass measurements at BigRIPS-SLOWRI

The atomic masses of $^{55}$Sc, $^{56,58}$Ti, and $^{56-59}$V have been determined using the high-precision multi-reflection time-of-flight technique. The radioisotopes have been produced at RIKEN's RIBF facility and delivered to the novel designed gas cell and multi-reflection system (ZD MRTOF), which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For $^{56,58}$Ti and $^{56-59}$V the mass uncertainties have been reduced down to the order of $10\,\mathrm{keV}$, shedding new light on the $N=34$ shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species $^{58}$Ti and $^{59}$V. With the new precision achieved, we reveal the non-existence of the $N=34$ empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied $νp_{3/2}$ orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the $νd_{5/2}$ and $νg_{9/2}$ orbits and compare the results with conventional shell model calculations, which exclude the $νg_{9/2}$ and the $νd_{5/2}$ orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at $N=34$.

nucl-ex

The new MRTOF mass spectrograph following the ZeroDegree spectrometer at RIKEN's RIBF facility

A newly assembled multi-reflection time-of-flight mass spectrograph (MRTOF-MS) at RIKEN's RIBF facility became operational for the first time in spring 2020; further modifications and performance tests using stable ions were completed in early 2021. By using a pulsed-drift-tube technique to modify the ions' kinetic energy in a wide range, we directly characterize the dispersion function of the system for use in a new procedure for optimizing the voltages applied to the electrostatic mirrors. Thus far, a mass resolving power of $R_m > 1\,000\,000$ is reached within a total time-of-flight of only $12.5\,\mathrm{ms}$, making the spectrometer capable of studying short-lived nuclei possessing low-lying isomers. Detailed information about the setup and measurement procedure is reported, and an alternative in-MRTOF ion selection scheme to remove molecular contaminants in the absence of a dedicated deflection device is introduced. The setup underwent an initial on-line commissioning at the BigRIPS facility at the end of 2020, where more than 70 nuclear masses have been measured. A summary of the commissioning experiments and results from a test of mass accuracy will be presented.

physics.ins-det

First direct observation of isomeric decay in neutron-rich odd-odd $^{186}$Ta

De-excitation $γ$ rays associated with an isomeric state of $^{186}$Ta were investigated. The isomers were produced in multinucleon transfer reactions between a $^{136}$Xe beam and a natural W target, and were collected and separated by the KEK Isotope Separation System. Two $γ$ transitions with energies of 161.1(2) and 186.8(1) keV associated with an isomeric decay were observed for the first time. The half-life of the isomeric state of the neutral atom $^{186 \rm m}$Ta was deduced as 17(2) s. Based on the comparison with the previous measurements of the isomeric state using the ESR storage ring at GSI Darmstadt and the coupling of angular momenta of individual particle orbitals in odd-odd nuclei, a decay scheme of $^{186 \rm m}$Ta was proposed.

nucl-ex

First high-precision direct determination of the atomic mass of a superheavy nuclide

We present the first direct measurement of the atomic mass of a superheavy nuclide. Atoms of $^{257}$Db ($Z$=105) were produced online at the RIKEN Nishina Center for Accelerator-Based Science using the fusion-evaporation reaction $^{208}$Pb($^{51}$V, 2n)$^{257}$Db. The gas-filled recoil ion separator GARIS-II was used to suppress both the unreacted primary beam and some transfer products, prior to delivering the energetic beam of $^{257}$Db ions to a helium gas-filled ion stopping cell wherein they were thermalized. Thermalized $^{257}$Db$^{3+}$ ions were then transferred to a multi-reflection time-of-flight mass spectrograph for mass analysis. An alpha particle detector embedded in the ion time-of-flight detector allowed disambiguation of the rare $^{257}$Db$^{3+}$ time-of-flight detection events from background by means of correlation with characteristic $α$-decays. The extreme sensitivity of this technique allowed a precision atomic mass determination from 11 events. The mass excess was determined to be $100\,063(231)_\textrm{stat}(132)_\textrm{sys}$~keV/c$^2$. Comparing to several mass models, we show the technique can be used to unambiguously determine the atomic number as $Z$=105 and should allow similar evaluations for heavier species in future work.

nucl-ex

Properties of 187Ta revealed through isomeric decay

Mass-separated 187Ta in a high-spin isomeric state has been produced for the first time by multi-nucleon transfer reactions, employing an argon gas stopping cell and laser ionisation. Internal gamma rays revealed a 7.3 s isomer at 1778 keV, which decays through a rotational band with perturbations associated with the approach to a prolate-oblate shape transition. Model calculations show less influence from triaxiality compared to heavier elements in the same mass region. The isomer decay reduced E2 hindrance factor of 27 supports the interpretation that axial symmetry is approximately conserved.

nucl-ex

High precision mass measurements of the isomeric and ground states of $^{44}$V: improving constraints on the IMME parameters of the A=44, $\text{0}^{\text{+}}$ quintet

The Isobaric Multiplet Mass Equation (IMME) has been successful at predicting the masses of isobaric analogue states in the same multiplet, while its coefficients are known to follow trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] $^{44}$V mass value results in an negative $c$ coefficient for the IMME quadratic term. The $b$ and $c$ coefficients can provide constraints for construction of the isospin-nonconserving (INC) Hamiltonians for the $pf$ shell. The excitation energy of the $0^+, T=2$ level in $^{44}$V is currently unknown and can be used to constrain the $^{44}$Cr mass. The aim of the experiment was to perform high-precision mass measurements to resolve the difference between $^{44}$V isomeric and ground states, to test the IMME, and to provide ingredients for identifying the $0^+$, $T=2$ state in $^{44}$V. High-precision Penning trap mass spectrometry was performed at LEBIT, to measure the cyclotron frequency ratios of [$^{44g,m}$VO]$^+$ versus [$^{32}$SCO]$^+$, a reference mass, to extract both the isomeric and ground state masses of $^{44}$V. The mass excess of the ground and isomeric states in $^{44}$V were measured to be $-23\ 804.9(80)$ keV/$\text{c}^2$ and $-23\ 537.0(55)$ keV/$\text{c}^2$. This yielded a new proton separation energy of $S_p$ = 1\ 773(10) keV. The new mass values of $^{44}$V have been used to deduce the IMME $b$ and $c$ coefficients of the lowest $2^+$ and $6^+$ triplets in $A=44$. The $2^+$ $c$ coefficient is verified with the IMME trend and agrees with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between $^{44}$V and $^{44}$Sc, in line with isospin-symmetry. The new value of the proton separation energy determined will be important for the determination of the $0^+$, $T=2$ state in $^{44}$V and for prediction of the mass of $^{44}$Cr.

nucl-ex

Accurately accounting for effects on times-of-flight caused by finite field-transition times during the ejection of ions from a storage trap: A study for TOF and MRTOF mass spectrometry

In applied forms of time-of-flight mass spectrometry utilizing ion storage devices prior to an analysis device, a non instantaneous electric ejection pulse applied in the region of ion storage is used to accelerate ions into the time-of-flight analyzer. The calculated mass value of the ions from the time-of-flight is dependent on the duration of the field transition up to full strength. For novel applications dedicated to precision measurements, such as multi-reflection time-of-flight mass spectrometry of short-lived isotopes, the goal is to continuously decrease the measurement uncertainty while providing a mass accuracy on the same order. Even though dynamic-field models for time-of-flight mass spectrometry have been considered in the past for technological advances, it is important to study the accuracy of the measured mass in this context. Using a simplified linear model for the field transition, we provide a basic investigation of the scenario, and discuss the deviation from the classical "mass-over-charge" dependency of the ions' time-of-flight, which becomes violated. The emerging mass discrepancy depends on the distance between the mass of the ion used for calibration and that of the ion of interest and, in extreme cases, can increase to about one percent for systems with short times-of-flight. However, for typical conditions in single-reference multi-reflection time-of-flight mass spectrometry, mass deviations caused by this effect typically remain below the 1 ppm level. If a mass calibration using two or more ion species is possible during the measurement, the effect becomes negligible for appropriate choices of reference masses.

physics.ins-det

High-stability, high-voltage power supplies for use with multi-reflection time-of-flight mass spectrographs

Achieving the highest possible mass resolving power in a multi-reflection time-of-flight mass spectrometer requires very high-stability power supplies. To this end, we have developed a programmable high-voltage power supply that can achieve long-term stability on the order of parts-per-million. Herein we present the design of the stable high-voltage system and bench-top stability measurements up to 1~kV; the stabilization technique can, in principle, be applied up to 15~kV or more.. We demonstrate that in the $\le$1~Hz band the output stability is on the level of 1~part per million (ppm) during one hour, with only slightly more output variation across 3 days. We further demonstrate that the output is largely free of noise in the 1~Hz -- 200~Hz band. We also demonstrate settling to the ppm level within one minute following a 100~V step transition. Finally, we demonstrate that when these power supplies are used to bias the electrodes of a multi-reflection time-of-flight mass spectrograph the measured time-of-flight is stable on the ppm-level for at least one hour.

physics.ins-det

Development of an "$α$-ToF" detector for correlated measurement of atomic masses and decay properties

We have developed a novel detector, referred to as an "$α$-ToF detector", for correlated measurements of atomic masses and decay properties of low-yield, short-lived radioactive isotopes using a multi-reflection time-of-flight mass spectrograph. By correlating measured time-of-flight signals with decay events, it will be possible to suppress background events and obtain accurate, high-precision mass values even in cases of very low event rates. An offline test of the $α$-ToF detector has shown that the time-of-flight detection efficiency for 5.48~MeV $α$-rays is more than 90\% and yields a time resolution of 251.5(68)~ps and an energy resolution of 141.1(9)~keV. Using a two-dimensional spectrum of the correlated $α$-ray energy and time-of-flight, the $α$-rays from mixed $α$ sources could be fairly well resolved.

physics.ins-det

An inexpensive biasing system for use in electrostatic steering of ions

We introduce a compact design for an electronic device capable of superposing 8 bias voltages up to $\pm$96~V on a voltage of up to 5~kV. Such a device has been implemented to provide biasing of a beam steerer-shifter system for use in aligning an ion beam with the optical axis of a multi-reflection time-of-flight mass spectrograph. The device features a 16-bit digital interface both to set and to monitor the applied voltages, and can be built for less than \$500~USD. By selection of higher isolation components, the design concept can be extended to allow operation up to 20~kV.

physics.ins-det

New mass anchor points for neutron-deficient heavy nuclei from direct mass measurements of radium and actinium isotopes

The masses of the exotic isotopes $^{210-214}$Ac and $^{210-214}$Ra have been measured with a multi-reflection time-of-flight mass spectrograph. These isotopes were obtained in flight as fusion-evaporation products behind the gas-filled recoil ion separator GARIS-II at RIKEN. The new direct mass measurements serve as an independent and direct benchmark for existing $α$-$γ$ spectroscopy data in this mass region. Further, new mass anchor points are set for U and Np nuclei close to the $N=126$ shell closure for a future benchmark of the $Z=92$ sub-shell for neutron-deficient heavy isotopes. Our mass results are in general in good agreement with the previously indirectly-determined mass values. Together with the measurement data, reasons for possible mass ambiguities from decay-data links between ground states are discussed.

nucl-ex

Improving wide-band mass measurements in a multi-reflection time-of-flight mass spectrograph by usage of a concomitant measurement scheme

We introduce a new concomitant referencing mode for operating a multi-reflection time-of-flight mass spectrograph (MRTOF-MS), wherein the reference and analyte ions are interleaved on a cycle by cycle bases. Using this mode, we demonstrate an improved technique for performing wide bandwidth mass measurements via MRTOF-MS. This new technique offers a simplified analysis and high-accuracy.

physics.ins-det

First direct mass measurements of nuclides around $Z=100$ with a Multireflection Time-of-Flight Mass Spectrograph

The masses of $^{246}$Es, $^{251}$Fm and the transfermium nuclei $^{249-252}$Md, and $^{254}$No, produced by hot- and cold-fusion reactions, in the vicinity of the deformed $N=152$ neutron shell closure, have been directly measured using a multireflection time-of-flight mass spectrograph. The masses of $^{246}$Es and $^{249,250,252}$Md were measured for the first time. Using the masses of $^{249,250}$Md as anchor points for $α$ decay chains, the masses of heavier nuclei, up to $^{261}$Bh and $^{266}$Mt, were determined. These new masses were compared with theoretical global mass models and demonstrated to be in good agreement with macroscopic-microscopic models in this region. The empirical shell gap parameter $δ_{2n}$ derived from three isotopic masses was updated with the new masses and corroborate the existence of the deformed $N=152$ neutron shell closure for Md and Lr.

nucl-ex