SearcharxivSearch

arXiv subjects

P. Strasser

Publications and source records attributed to P. Strasser.

13 recordsLinked to original sources

Measurement of production branching ratio after muon nuclear capture reaction of Al and Si isotopes

Background: Muon nuclear capture is a reaction between a muon and a proton inside a nucleus through weak interactions. This reaction results in the formation of an excited nucleus, which subsequently de-excites by emitting several particles. Examination of the excited state allows for an investigation of the properties of nuclear excitation and particle emission in highly excited nuclei. Purpose: This study investigates muon nuclear capture of 27Al and 28,29,30Si, focusing on determining the absolute production branching ratio (BR) following muon nuclear capture and subsequent particle emissions. By measuring the absolute production BR, we can collect valuable information on the excitation energy distribution of muon nuclear capture. Methods: Measurements were conducted using the in-beam activation method at two pulsed muon facilities: RIKEN-RAL beamline and MLF at J-PARC. Absolute BRs were determined by measuring the number of muons irradiating the target using a plastic scintillator and the beta-delayed gamma-rays emitted from the produced nuclei using germanium detectors. Results: The absolute production branching ratios of muon nuclear capture on 27Al and 28,29,30Si were obtained with the highest accuracy to date. Predominant neutron emissions, even-odd atomic number dependence of particle emission probabilities, and influence of the neutron excess were observed. These results were compared with previous measurements and theoretical models and discussed regarding the excitation energy distribution, particle emission mechanism, and nuclear properties, such as resonance in the isovector transition. Conclusion: This study emphasizes the importance of considering nuclear structure effects, even-odd effects of proton and neutron numbers, neutron excess, nucleon pairing effect, and particle emission mechanisms, in the context of the muon nuclear capture reaction.

nucl-ex

Acceleration of positive muons by a radio-frequency cavity

Acceleration of positive muons from thermal energy to $100~$keV has been demonstrated. Thermal muons were generated by resonant multi-photon ionization of muonium atoms emitted from a sheet of laser-ablated aerogel. The thermal muons were first electrostatically accelerated to $5.7~$keV, followed by further acceleration to 100 keV using a radio-frequency quadrupole. The transverse normalized emittance of the accelerated muons in the horizontal and vertical planes were $0.85 \pm 0.25 ~\rm{(stat.)}~^{+0.22}_{-0.13} ~\rm{(syst.)}~\pi~$mm$\cdot$mrad and $0.32\pm 0.03~\rm{(stat.)} ^{+0.05}_{-0.02} ~\rm{(syst.)}~\pi~$mm$\cdot$mrad, respectively. The measured emittance values demonstrated phase space reduction by a factor of $2.0\times 10^2$ (horizontal) and $4.1\times 10^2$ (vertical) allowing good acceleration efficiency. These results pave the way to realize the first-ever muon accelerator for a variety of applications in particle physics, material science, and other fields.

physics.acc-ph

Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays

Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.

physics.atom-ph

Improved Measurements of Muonic Helium Ground-State Hyperfine Structure at a Near-Zero Magnetic Field

Muonic helium atom hyperfine structure (HFS) measurements are a sensitive tool to test the three-body atomic system and bound-state quantum electrodynamics theory, and determine fundamental constants of the negative muon magnetic moment and mass. The world's most intense pulsed negative muon beam at the Muon Science Facility of the Japan Proton Accelerator Research Complex allows improvement of previous measurements and testing further $CPT$ invariance by comparing the magnetic moments and masses of positive and negative muons (second-generation leptons). We report new ground-state HFS measurements of muonic helium-4 atoms at a near-zero magnetic field, performed for the first time using a small admixture of CH$_{4}$ as an electron donor to form neutral muonic helium atoms efficiently. Our analysis gives $\Delta\nu$ = 4464.980(20) MHz (4.5 ppm), which is more precise than both previous measurements at weak and high fields. The muonium ground-state HFS was also measured under the same conditions to investigate the isotopic effect on the frequency shift due to the gas density dependence in He with CH$_{4}$ admixture and compared with previous studies. Muonium and muonic helium can be regarded as light and heavy hydrogen isotopes with an isotopic mass ratio of 36. No isotopic effect was observed within the current experimental precision.

physics.atom-ph

Muonic X-Ray Measurement for the Nuclear Charge Distribution: the Case of Stable Palladium Isotopes

Background: The nuclear charge radius and distribution are the most fundamental quantities of the atomic nucleus. From the muonic transition energies, the absolute charge radius has been experimentally obtained, while there have been no established methods to discuss the distribution. Purpose: The muonic transition energies for five palladium isotopes with the mass number $A = 104$, $105$, $106$, $108$ and $110$ were measured. The procedure to deduce the charge radii and the method to discuss the charge distribution from the muonic transition energies are proposed. Method: The experiment was performed at the MuSIC-M1 beamline at Research Center for Nuclear Physics, Osaka University. A continuous muon beam impinged on the enriched palladium targets. Muonic X rays were measured by high-purity germanium detectors. Results: The muonic transition energies up to $4f$-$3d$ transitions were determined for five palladium isotopes. Discussion and conclusion: The root-mean-square charge radii are deduced assuming the two-parameter Fermi distribution. The charge distribution of the nucleus is discussed employing the Barrett model. The muonic transition energies of the $3d$-$2p$ transitions are crucial to discuss both the charge radius and the charge distribution.

nucl-ex

Development of microwave cavities for measurement of muonium hyperfine structure at J-PARC

The MuSEUM collaboration is planning measurements of the ground-state hyperfine structure (HFS) of muonium at the Japan Proton Accelerator Research Complex (J-PARC), Materials and Life Science Experimental Facility. The high-intensity beam that will soon be available at H-line allows for more precise measurements by one order of magnitude. We plan to conduct two staged measurements. First, we will measure the Mu-HFS in a near-zero magnetic field, and thereafter we will measure it in a strong magnetic field. We have developed two microwave cavities for this purpose. Furthermore, we evaluated systematic uncertainties from such a fluctuation of microwave fields and confirm the requirement of the microwave system, we use a microwave field distribution calculated from the finite element method.

physics.ins-det

Rabi-Oscillation Spectroscopy of the Hyperfine Structure of Muonium Atoms

As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency sweep. Furthermore, the data under different conditions can be treated in a unified manner, allowing more efficient measurements for systems consisting of a limited number of short-lived particles produced by accelerators such as muons. We have developed a fitting function that takes into account the spatial distribution of muonium and the spatial distribution of the microwave intensity to apply the new method to ground-state muonium hyperfine structure measurements at zero field. This was applied to the actual measurement data and the resonance frequencies were determined under various conditions. The result of our analysis gives $\nu_{\rm HFS}=4\ 463\ 301.61 \pm 0.71\ {\rm kHz}$, which is the world's highest precision under zero field conditions.

hep-ex

New precise spectroscopy of the hyperfine structure in muonium with a high-intensity pulsed muon beam

A hydrogen-like atom consisting of a positive muon and an electron is known as muonium. It is a near-ideal two-body system for a precision test of bound-state theory and fundamental symmetries. The MuSEUM collaboration performed a new precision measurement of the muonium ground-state hyperfine structure at J-PARC using a high-intensity pulsed muon beam and a high-rate capable positron counter. The resonance of hyperfine transition was successfully observed at a near-zero magnetic field, and the muonium hyperfine structure interval of ${\nu}_{\text{HFS}}$ = 4.463302(4) GHz was obtained with a relative precision of 0.9 ppm. The result was consistent with the previous ones obtained at Los Alamos National Laboratory and the current theoretical calculation. We present a demonstration of the microwave spectroscopy of muonium for future experiments to achieve the highest precision.

hep-ex

A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment

This paper introduces a new approach to measure the muon magnetic moment anomaly $a_{\mu} = (g-2)/2$, and the muon electric dipole moment (EDM) $d_{\mu}$ at the J-PARC muon facility. The goal of our experiment is to measure $a_{\mu}$ and $d_{\mu}$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_{\mu}$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.

physics.ins-det

Enhancement of muonium emission rate from silica aerogel with a laser ablated surface

Emission of muonium ($\mu^+e^-$) atoms from a laser-processed aerogel surface into vacuum was studied for the first time. Laser ablation was used to create hole-like regions with diameter of about 270$~\mu$m in a triangular pattern with hole separation in the range of 300--500$~\mu$m. The emission probability for the laser-processed aerogel sample is at least eight times higher than for a uniform one.

physics.ins-det

Measurement of muonium emission from silica aerogel

Emission of muonium ($\mu^{+}e^{-}$) atoms from silica aerogel into vacuum was observed. Characteristics of muonium emission were established from silica aerogel samples with densities in the range from 29 mg cm$^{-3}$ to 178 mg cm$^{-3}$. Spectra of muonium decay times correlated with distances from the aerogel surfaces, which are sensitive to the speed distributions, follow general features expected from a diffusion process, while small deviations from a simple room-temperature thermal diffusion model are identified. The parameters of the diffusion process are deduced from the observed yields.

physics.atom-ph

A search for deeply bound kaonic nuclear states

We have measured proton and neutron energy spectra by stopping negative kaons on liquid helium4. Two distinct peak structures were found on both spectra, which were assigned to the formation of new kinds of strange stribaryons. In this paper, we summarize both results.

nucl-ex

Indication of a strange tribaryon S^+ from the ^4He(stopped K^-,n) reaction

We measured the neutron time-of-flight spectrum in the ^4He(stopped K^-, n) reaction by stopping negative kaons in a superfluid helium target. A clear enhancement was observed in the neutron spectrum, which indicates the formation of a strange tribaryon of charge +1 with a mass and width of M = 3141 +/- 3 (stat.) +4/-1 (sys.) MeV/c^2 and G < 23 MeV/c^2. This state, denoted as S^+(3140), is about 25 MeV/c^2 higher than the previously observed S^0(3115) T=1.

nucl-ex