SearcharxivSearch

arXiv subjects

P. Szypryt

Publications and source records attributed to P. Szypryt.

12 recordsLinked to original sources

A microwave SQUID multiplexing concept for macro-cryogenic calorimeter arrays

Massive cryogenic calorimeters read out by transition-edge sensors (TES) can reach eV-scale baseline resolution, but the single-channel dc-SQUID readout conventionally used in rare-event searches, with one amplifier chain and several wires per detector, limits practical arrays to a few tens of channels. We propose to apply microwave SQUID multiplexing ($μ$MUX), developed for fast X-ray and neutrino-mass microcalorimeters, to massive BGO (Bi$_4$Ge$_3$O$_{12}$) calorimeters operated at $\simeq 20$~mK; sapphire and TeO$_2$ absorbers are covered by the same framework. Using the established thermal and noise model for massive TES calorimeters, we derive a noise model for the multiplexed readout, including the HEMT, two-level-system and SQUID contributions, and its scaling with the multiplexing factor $N_{\rm mux}$. Since the slow thermal signals require only about a kHz of sampling per channel, the limiting requirement is not bandwidth but an input-coil sensitivity of $( 0.1$ to $1)\,μ$A$/Φ_0$, a factor of $10$ to $30$ beyond current $μ$MUX devices, matched to the detector current noise of ($9$ to $10$)~pA$/\sqrt{\rm Hz}$, which is independent of the absorber mass. With a total flux noise of $\simeq$$1.2\,μΦ_0/\sqrt{\rm Hz}$, the readout degrades the baseline resolution by less than $2\%$ up to $N_{\rm mux}=1000$, negligible compared with the TES-limited resolution. These results are implemented in a single-tower design: 52 BGO crystals of 100~g each and one HEMT amplifier. The tower is the unit of a multi-tower array of several kilograms aimed at CE$ν$NS and dark matter searches.

physics.ins-det

X-ray magnetic circular dichroism and resonant inelastic X-ray scattering explained: role of many-body correlation and valence fluctuations

X-ray magnetic circular dichroism (XMCD) and resonant inelastic X-ray scattering with magnetic circular dichroism (RIXS-MCD) provide unparalleled insights into the electronic and magnetic dynamics of complex materials. However, interpreting their spectra in mixed-valence systems remains challenging due to intricate many-body interactions and enhanced charge fluctuations. In this study, by utilizing the Anderson impurity model with a full consideration of charge transfer (CT), many-body core-valence exchange correlation (CVEC) effects, and Jahn-Teller (JT) distortions, we systematically investigate the XMCD and RIXS-MCD spectra for a prototypical mixed-valence ferromagnet, La$_{0.7}$Sr$_{0.3}$MnO$_3$ film. We demonstrate that simple calculation with limited CT effects fails to capture characteristic substructures observed experimentally. In contrast, an adequate treatment of CT and CVEC effects yields a more consistent description of both XMCD and RIXS-MCD spectra, providing practical guidance for the interpretation of dichroic x-ray spectroscopies in mixed-valence transition-metal oxides. Furthermore, we discuss the role of the JT effect in Mn$^{3+}$ ions in the determination of their spectra.

cond-mat.str-el

On low-energy tail distortions in the detector responsefunction of x-ray microcalorimeter spectrometers

We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fraction measurements. In this model a low energy tail arises fromthe combination of electron escape and energy trapping associated with Bi x-rayabsorbers.

physics.ins-det

A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap

We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ~30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8,000 eV and achieve an energy resolution of 3.7 eV to 5.0 eV over this range, a more modest (<2X) improvement over the previous microcalorimeters. Beyond this energy range NETS can operate with various trade-offs, the most significant of which are reduced efficiency at lower energies and being limited to a subset of the pixels at higher energies. As an initial demonstration of the capabilities of NETS, we measured transitions in He-like and H-like O, Ne, and Ar as well as Ni-like W. We detail the energy calibration and data analysis techniques used to transform detector counts into x-ray spectra, a process that will be the basis for analyzing future data.

physics.ins-det

Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy

We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 um.

astro-ph.IM

High Quality Factor Platinum Silicide Microwave Kinetic Inductance Detectors

We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single photons to better than two microseconds and their energies to around ten percent. Previously, MKIDs have been fabricated using either sub-stoichiometric titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in the superconducting critical temperature and Al has a low kinetic inductance fraction, causing low detector sensitivity. To address these issues, we have instead fabricated PtSi microresonators with superconducting critical temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim 10^6$). These devices show typical quasiparticle lifetimes of $τ_{qp} \approx 30$--$40~μ$s and spectral resolution, $R = λ/ Δλ$, of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail the substantial advantages that PtSi MKIDs have to offer.

physics.ins-det

Search for Optical Pulsations in PSR J0337+1715

We report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telescope at Palomar Observatory. No significant pulsations were found in the range 4000-11000 angstroms, and we can limit pulsed emission in g-band to be fainter than 25 mag.

astro-ph.HE

The ARCONS Pipeline: Data Reduction for MKID Arrays

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. We outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

astro-ph.IM

Ultraviolet, Optical, and Near-IR Microwave Kinetic Inductance Detector Materials Developments

We have fabricated 2024 pixel microwave kinetic inductance detector (MKID) arrays in the ultraviolet/optical/near-IR (UVOIR) regime that are currently in use in astronomical instruments. In order to make MKIDs desirable for novel instruments, larger arrays with nearly perfect yield need to be fabricated. As array size increases, however, the percent yield often decreases due to frequency collisions in the readout. The per-pixel performance must also be improved, namely the energy resolution. We are investigating ways to reduce frequency collisions and to improve the per pixel performance of our devices through new superconducting material systems and fabrication techniques. There are two main routes that we are currently exploring. First, we are attempting to create more uniform titanium nitride films through the use of atomic layer deposition rather than the more traditional sputtering method. In addition, we are experimenting with completely new material systems for MKIDs, such as platinum silicide.

physics.ins-det

Excess Optical Enhancement Observed with ARCONS for Early Crab Giant Pulses

We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARCONS, a unique superconducting energy-resolving photon-counting array at the Palomar 200-inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an $11.3\pm2.5\%$ increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.

astro-ph.HE

Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS

AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS, sensitive to radiation from 350 to 1100 nm, has a time resolution of several microseconds and can measure the energy of a photon to $\sim10%$. We present the light curves for these observations and examine changes in orbital period from prior observations. Using a quadratic ephemeris model, we measure a period rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use the high timing resolution of ARCONS to examine the system's high frequency variations and search for possible quasi-periodic oscillations (QPOs). Finally, we use the instrument's spectral resolution to examine the light curves in various wavelength bands. We do not find any high frequency QPOs or significant spectral variability throughout an eclipse.

astro-ph.SR

ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer

We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs are nearly ideal, noiseless photon detectors, as they do not suffer from read noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is an Integral Field Spectrograph (IFS) containing a lens-coupled 2024 pixel MKID array yielding a 20"x20" field of view, and has been deployed on the Palomar 200" and Lick 120" telescopes for 24 nights of observing. We present initial results showing that ARCONS and its MKID arrays are now a fully operational and powerful tool for astronomical observations.

astro-ph.IM