Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons

Range uncertainties remain a major limitation to the full clinical exploitation of proton therapy, motivating reliable in-vivo range-verification techniques. This work presents an experimental investigation of a hybrid Prompt-Gamma Imaging (PGI)--Positron-Emission Tomography (PET) concept at the isochronous cyclotron of the West German Proton Therapy Centre under clinically representative pencil-beam-scanning conditions. Because this accelerator delivers a quasi-continuous beam, a pulsed shoot-and-step structure was imposed to mimic the interruptions associated with clinical energy-layer switching. This enabled PGI during irradiation and PET and delayed Compton imaging during beam-off intervals within the same sequence. Four two-plane Compton cameras were arranged in a co-planar cross-shaped geometry around the beam isocenter. Polyethylene phantoms were irradiated with 100~MeV protons at known positions along the beam axis. Their positions were estimated from reconstructed one-dimensional profiles using supervised machine-learning models trained exclusively on Monte Carlo simulations. PET achieved the best performance, with a root-mean-square deviation of 0.8~mm, followed by PGI with 1.6~mm. Delayed Compton imaging based on e$^{+}$ annihilation photons and $^{10}$C$^{*}$ decays yielded 2.4~mm and 3.8~mm, respectively. PET retained good performance down to 1% of the original event statistics, whereas PGI became increasingly statistics-limited. These results demonstrate the complementary strengths of hybrid PGI--PET and support its development towards millimetre-scale proton-range verification under clinically relevant irradiation conditions.

physics.med-ph↗

Imaging neutrons with a position-sensitive monolithic CLYC detector

In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $γ$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at simultaneously obtaining information about the spatial origin of \g-ray and neutron sources. We first investigated the performance of large 50$\times$50~mm$^{2}$ monolithic CLYC crystals coupled to a pixelated SiPM in terms of energy resolution and neutron-gamma discrimination. The response of two different 95\% $^{6}$Li-enriched CLYC detectors coupled to an array of 8$\times$8 SiPMs was studied in comparison to the results of a conventional photo-multiplier tube. Energy resolution ranging from 6-8\% for the $^{137}$Cs peak and a figure of merit of 3-4 for the neutron-gamma discrimination have been obtained. The spatial response of the CLYC-SiPM detector to $γ$-rays and neutrons has also been characterized using charge modulation-based multiplexing techniques based on a diode-coupled charge division circuit. Average resolutions close to 5~mm FWHM with good linearity are obtained in the transverse crystal plane. Last, this work presents the first proof-of-concept experiments of the neutron imaging capability using a neutron pinhole collimator attached to the developed position sensitive CLYC detector.

physics.ins-det↗

First Pilot Tests of Compton Imaging and Boron Concentration Measurements in BNCT Using i-TED

Dosimetry in BNCT poses significant challenges due to the indirect effect of neutrons interacting with elements within the body and uncertainties associated with the uptake of boron compounds used in clinical practice. Current treatment planning relies on unconventional estimates of boron tumor uptake derived from prior PET scans and thus, an online boron-uptake monitor would be highly convenient. This work presents the first pilot experiments carried out at ILL-Grenoble with the high-efficiency Compton camera i-TED, hereby aiming at demonstrating its applicability for BNCT dosimetry by introducing real-time measurement of the boron concentration and imaging capabilities of spatial dose distribution. In this experiment, we measured the $^{10}$B uptake of different cancer cells of tongue squamous cell carcinoma, malignant melanoma and glioblastoma treated with BPA (80~ppm of $^{10}$B). The samples were irradiated with the thermal neutron spectrum of ILL-Grenoble and the 478keV $γ$-rays from the $^{7}$Li de-excitation after the neutron-boron reaction were registered both with the Compton imager and the high-sensitivity FIPPS HPGe array. These series of measurements allowed us to demonstrate the imaging capabilities of the Compton imaging device for the 478 keV $γ$-rays of interest for dosimetry in BNCT, as well as to assess its sensitivity, which was found to be below 1 $μ$g of $^{10}$B.

physics.med-ph↗

Measurement of the $^{14}$N(n,p)$^{14}$C cross section at the CERN n_TOF facility from sub-thermal energy to 800 keV

Background: The $^{14}$N(n,p)$^{14}$C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring the 14N(n,p)14C cross section from thermal to the resonance region in a single measurement for the first time, including characterization of the first resonances, and providing calculations of Maxwellian averaged cross sections (MACS). Method: Time-of-flight technique. Experimental Area 2 (EAR-2) of the neutron time-of-flight (n_TOF) facility at CERN. $^{10}$B(n,$α$)$^7$Li and $^{235}$U(n,f) reactions as references. Two detection systems running simultaneously, one on-beam and another off-beam. Description of the resonances with the R-matrix code sammy. Results: The cross section has been measured from sub-thermal energy to 800 keV resolving the two first resonances (at 492.7 and 644 keV). A thermal cross-section (1.809$\pm$0.045 b) lower than the two most recent measurements by slightly more than one standard deviation, but in line with the ENDF/B-VIII.0 and JEFF-3.3 evaluations has been obtained. A 1/v energy dependence of the cross section has been confirmed up to tens of keV neutron energy. The low energy tail of the first resonance at 492.7 keV is lower than suggested by evaluated values, while the overall resonance strength agrees with evaluations. Conclusions: Our measurement has allowed to determine the $^{14}$N(n,p) cross-section over a wide energy range for the first time. We have obtained cross-sections with high accuracy (2.5 %) from sub-thermal energy to 800 keV and used these data to calculate the MACS for kT = 5 to kT = 100 keV.

nucl-ex↗