SearcharxivSearch

arXiv subjects

P. Travnicek

Publications and source records attributed to P. Travnicek.

12 recordsLinked to original sources

Analysis of commissioning data from SST-1M : A Prototype of Single-Mirror Small Size Telescope

SST-1M is a prototype of a single-mirror Small Size Telescope developed by a consortium of institutes from Poland, Switzerland and the Czech Republic. With a wide field of view of 9 degrees, SST-1Ms are designed to detect gamma-rays in the energy range between 1 and 300 TeV. The design of the SST-1M follows the Davies-Cotton concept, with a 9.42m2 multi-segment mirror. SST-1M is equipped with DigiCam camera, which features a fully digital readout and trigger system using 250 MHz ADC, and a compact Photo-Detector Plane (PDP) composed of 1296 pixels, each made of a hexagonal light guide coupled to silicone photomultipliers (SiPM). Two SST-1M telescopes are currently being commissioned at the Ondrejov Observatory in the Czech Republic, where they are successfully observing Cerenkov events in stereo. This contribution will present an overview of calibration strategies and performance evaluation based on data collected at the observatory.

astro-ph.IM

Whistler waves observed by Solar Orbiter / RPW between 0.5 AU and 1 AU

The goal of our study is to detect and characterize the electromagnetic waves that can modify the electron distribution functions, with a special attention to whistler waves. We analyse in details the electric and magnetic field fluctuations observed by the Solar Orbiter spacecraft during its first orbit around the Sun between 0.5 and 1 AU. Using data of the Search Coil Magnetometer and electric antenna, both parts of the Radio and Plasma Waves (RPW) instrumental suite, we detect the electromagnetic waves with frequencies above 3 Hz and determine the statistical distribution of their amplitudes, frequencies, polarization and k-vector as a function of distance. We also discuss relevant instrumental issues regarding the phase between the electric and magnetic measurements and the effective length of the electric antenna. An overwhelming majority of the observed waves are right hand circularly polarized in the solar wind frame and identified as outward propagating and quasi parallel whistler waves. Their occurrence rate increases by a least a factor two from 1 AU to 0.5 AU. These results are consistent with the regulation of the heat flux by the whistler heat flux instability. Near 0.5 AU, whistler waves are found to be more field-aligned and to have smaller normalized frequency ($f/f_{ce}$), larger amplitude, and larger bandwidth than at 1 AU.

astro-ph.SR

The First Full-Scale Prototypes of the Fluorescence detector Array of Single-pixel Telescopes

The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design concept for a next-generation UHECR observatory, addressing the requirements for a large-area, low-cost detector suitable for measuring the properties of ultra-high energy cosmic rays (UHECRs), having energies exceeding $10^{19.5}$\,eV, with an unprecedented aperture. We have developed a full-scale prototype consisting of four 200\,mm diameter photo-multiplier tubes at the focus of a segmented mirror of 1.6\,m in diameter. In October 2016, September 2017, and September 2018 we installed three such prototypes at the Black Rock Mesa site of the Telescope Array experiment in central Utah, USA. All three telescopes have been steadily taking data since installation. We report on the design and installation of these prototypes, and present some preliminary results, including measurements of artificial light sources, distant ultraviolet lasers, and UHECRs. Furthermore, we discuss some additional uses for these simplified low-cost fluorescence telescopes, including the facilitation of a systematic comparison of the transparency of the atmosphere above the Telescope Array experiment and the Pierre Auger Observatory, a study of the systematic uncertainty associated with the existing fluorescence detectors of these two experiments, and a cross-calibration of their energy and $X_{\text{max}}$ scales.

astro-ph.HE

Performance of a small size telescope (SST-1M) camera for gamma-ray astronomy with the Cherenkov Telescope Array

The foreseen implementations of the Small Size Telescopes (SST) in CTA will provide unique insights into the highest energy gamma rays offering fundamental means to discover and under- stand the sources populating the Galaxy and our local neighborhood. Aiming at such a goal, the SST-1M is one of the three different implementations that are being prototyped and tested for CTA. SST-1M is a Davies-Cotton single mirror telescope equipped with a unique camera technology based on SiPMs with demonstrated advantages over classical photomultipliers in terms of duty-cycle. In this contribution, we describe the telescope components, the camera, and the trigger and readout system. The results of the commissioning of the camera using a dedicated test setup are then presented. The performances of the camera first prototype in terms of expected trigger rates and trigger efficiencies for different night-sky background conditions are presented, and the camera response is compared to end-to-end simulations.

astro-ph.IM

Development of a strategy for calibrating the novel SiPM camera of the SST-1M telescope proposed for the Cherenkov Telescope Array

CTA will comprise a sub-array of up to 70 small size telescopes (SSTs) at the southern array. The SST-1M project, a 4 m-diameter Davies Cotton telescope with 9 degrees FoV and a 1296 pixels SiPM camera, is designed to meet the requirements of the next generation ground based gamma-ray observatory CTA in the energy range above 3 TeV. Silicon photomultipliers (SiPM) cameras of gamma-ray telescopes can achieve good performance even during high night sky background conditions. Defining a fully automated calibration strategy of SiPM cameras is of great importance for large scale production validation and online calibration. The SST-1M sub-consortium developed a software compatible with CTA pipeline software (CTApipe). The calibration of the SST-1M camera is based on the Camera Test Setup (CTS), a set of LED boards mounted in front of the camera. The CTS LEDs are operated in pulsed or continuous mode to emulate signal and night sky background respectively. Continuous and pulsed light data analysis allows us to extract single pixel calibration parameters to be used during CTA operation.

astro-ph.HE

Detection of ultra-high energy cosmic ray showers with a single-pixel fluorescence telescope

We present a concept for large-area, low-cost detection of ultra-high energy cosmic rays (UHECRs) with a Fluorescence detector Array of Single-pixel Telescopes (FAST), addressing the requirements for the next generation of UHECR experiments. In the FAST design, a large field of view is covered by a few pixels at the focal plane of a mirror or Fresnel lens. We report first results of a FAST prototype installed at the Telescope Array site, consisting of a single 200 mm photomultiplier tube at the focal plane of a 1 m$^2$ Fresnel lens system taken from the prototype of the JEM-EUSO experiment. The FAST prototype took data for 19 nights, demonstrating remarkable operational stability. We detected laser shots at distances of several kilometres as well as 16 highly significant UHECR shower candidates.

astro-ph.IM

On the Combined Analysis of Muon Shower Size and Depth of Shower Maximum

The mass composition of ultra-high energy cosmic rays can be studied from the distributions of the depth of shower maximum and/or the muon shower size. Here, we study the dependence of the mean muon shower size on the depth of shower maximum in detail. Air showers induced by protons and iron nuclei were simulated with two models of hadronic interactions already tuned with LHC data (run I-II). The generated air showers were combined to obtain various types of mass composition of the primary beam. We investigated the shape of the functional dependence of the mean muon shower size on the depth of shower maximum and its dependency on the composition mixture. Fitting this dependence we can derive the primary fractions and the muon rescaling factor with a statistical uncertainty at a level of few percent. The difference between the reconstructed primary fractions is below 20% when different models are considered. The difference in the muon shower size between the two models was observed to be around 6%.

astro-ph.IM

Signal Attenuation Curve for Different Surface Detector Arrays

Modern cosmic ray experiments consisting of large array of particle detectors measure the signals of electromagnetic or muon components or their combination. The correction for an amount of atmosphere passed is applied to the surface detector signal before its conversion to the shower energy. Either Monte Carlo based approach assuming certain composition of primaries or indirect estimation using real data and assuming isotropy of arrival directions can be used. Toy surface arrays of different sensitivities to electromagnetic and muon components are assumed in MC simulations to study effects imposed on attenuation curves for varying composition or possible high energy anisotropy. The possible sensitivity of the attenuation curve to the mass composition is also tested for different array types focusing on a future apparatus that can separate muon and electromagnetic component signals.

astro-ph.HE

AtmoHEAD 2013 workshop / Atmospheric Monitoring for High-Energy Astroparticle Detectors

A 3-day international workshop on atmospheric monitoring and calibration for high-energy astroparticle detectors, with a view towards next-generation facilities. The atmosphere is an integral component of many high-energy astroparticle detectors. Imaging atmospheric Cherenkov telescopes and cosmic-ray extensive air shower detectors are the two instruments driving the rapidly evolving fields of very-high- and ultra-high-energy astrophysics. In these instruments, the atmosphere is used as a giant calorimeter where cosmic rays and gamma rays deposit their energy and initiate EASs; it is also the medium through which the resulting Cherenkov light propagates. Uncertainties in real-time atmospheric conditions and in the fixed atmospheric models typically dominate all other systematic errors. With the improved sensitivity of upgraded IACTs such as H.E.S.S.-II and MAGIC-II and future facilities like the Cherenkov Telescope Array (CTA) and JEM-EUSO, statistical uncertainties are expected to be significantly reduced, leaving the atmosphere as the limiting factor in the determination of astroparticle spectra. Varying weather conditions necessitate the development of suitable atmospheric monitoring to be integrated in the overall instrument calibration, including Monte Carlo simulations. With expertise distributed across multiple collaborations and scientific domains, an interdisciplinary workshop is being convened to advance progress on this critical and timely topic.

astro-ph.IM

On the methods to determine signal attenuation curve for different surface arrays

Large surface arrays of current cosmic ray experiments measure the signals of electromagnetic or muonic components or their combination. The correction to the zenith angle (the attenuation curve) has to be taken into account before the signal is converted to the shower energy. Either Monte Carlo simulations or indirect estimation using collected data (Constant Intensity Cut method) can be used. However, the assumptions of composition or isotropy used for the determination of the attenuation curve can still influence the final physics results such as the energy spectrum, or modify anisotropy searches and composition analysis. Using simplified Toy Monte Carlo with an output from CORSIKA simulations we try to find several examples of what kind of effects can be caused by the methods of inferring the attenuation curve. Surface arrays of different sensitivities to electromagnetic and muonic components were considered.

astro-ph.HE

Prompt muons in extended air showers

We present results of simulations of a muon content in the air showers induced by very high energy cosmic rays. Muon energy distributions and muon densities at ground level are given. We discuss a prompt muon component generated by decays of charm mesons. The method combines standard Monte Carlo generators incorporated in the CORSIKA code and phenomenological estimates of the charm hadroproduction.

astro-ph

The Central Laser Facility at the Pierre Auger Observatory

The Central Laser Facility is located near the middle of the Pierre Auger Observatory in Argentina. It features a UV laser and optics that direct a beam of calibrated pulsed light into the sky. Light scattered from this beam produces tracks in the Auger optical detectors which normally record nitrogen fluorescence tracks from cosmic ray air showers. The Central Laser Facility provides a "test beam" to investigate properties of the atmosphere and the fluorescence detectors. The laser can send light via optical fiber simultaneously to the nearest surface detector tank for hybrid timing analyses. We describe the facility and show some examples of its many uses.

astro-ph