SearcharxivSearch

arXiv subjects

P. Trueb

Publications and source records attributed to P. Trueb.

3 recordsLinked to original sources

Signal height in silicon pixel detectors irradiated with pions and protons

Pixel detectors are used in the innermost part of multi purpose experiments at the Large Hadron Collider (LHC) and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of charged pions. The radiation hardness of the detectors has thoroughly been tested up to the fluences expected at the LHC. In case of an LHC upgrade the fluence will be much higher and it is not yet clear up to which radii the present pixel technology can be used. In order to establish such a limit, pixel sensors of the size of one CMS pixel readout chip (PSI46V2.1) have been bump bonded and irradiated with positive pions up to 6E14 Neq/cm^2 at PSI and with protons up to 5E15 Neq/cm^2. The sensors were taken from production wafers of the CMS barrel pixel detector. They use n-type DOFZ material with a resistance of about 3.7kOhm cm and an n-side read out. As the performance of silicon sensors is limited by trapping, the response to a Sr-90 source was investigated. The highly energetic beta-particles represent a good approximation to minimum ionising particles. The bias dependence of the signal for a wide range of fluences will be presented.

physics.ins-det

SM and MSSM Higgs Boson Production: Spectra at large transverse Momentum

Strategies for Higgs boson searches require the knowledge of the total production cross section and the transverse momentum spectrum. The large transverse momentum spectrum of the Higgs boson produced in gluon fusion can be quite different in the Standard Model and the Minimal Supersymmetric Standard Model. In this paper we present a comparison of the Higgs transverse momentum spectrum obtained using the PYTHIA event generator and the HIGLU program as well as the program HQT, which includes NLO corrections and a soft gluon resummation for the region of small transverse momenta. While the shapes of the spectra are similar for the Standard Model, significant differences are observed in the spectra of Minimal Supersymmetric Standard Model benchmark scenarios with large tan(beta).

hep-ph

Qualification Procedures of the CMS Pixel Barrel Modules

The CMS pixel barrel system will consist of three layers built of about 800 modules. One module contains 66560 readout channels and the full pixel barrel system about 48 million channels. It is mandatory to test each channel for functionality, noise level, trimming mechanism, and bump bonding quality. Different methods to determine the bump bonding yield with electrical measurements have been developed. Measurements of several operational parameters are also included in the qualification procedure. Among them are pixel noise, gains and pedestals. Test and qualification procedures of the pixel barrel modules are described and some results are presented.

physics.ins-det