Searcharxiv⌕ Search

arXiv subjects

P. Valente

Publications and source records attributed to P. Valente.

At least 37 records · Page 2Linked to original sources

Experimental characterization of the Gaussian state of squeezed light obtained via single-passage through an atomic vapor

We show that the description of light in terms of Stokes operators in combination with the assumption of Gaussian statistics results in a dramatic simplification of the experimental study of fluctuations in the light transmitted through an atomic vapor: no local oscillator is required, the detected quadrature is easily selected by a wave-plate angle and the complete noise ellipsis reconstruction is obtained via matrix diagonalization. We provide empirical support for the assumption of Gaussian statistics in quasi-resonant light transmitted through an $^{87}$Rb vapor cell and we illustrate the suggested approach by studying the evolution of the fluctuation ellipsis as a function of laser detuning. Applying the method to two light beams obtained by parting squeezed light in a beamsplitter, we have measured entanglement and quantum discord.

quant-ph↗

The PADME experiment at LNF

Massive photon-like particles are predicted in many extensions of the Standard Model. They have interactions similar to the photon, are vector bosons, and can be produced together with photons. The PADME experiment proposes a search for the dark photon ($A'$) in the $e^+e^- \to γA'$ process in a positron-on-target experiment, exploiting the positron beam of the DA$Φ$NE linac at the Laboratori Nazionali di Frascati, INFN. In one year of running a sensitivity in the relative interaction strength down to $10^{-6}$ is achievable, in the mass region from 2.5 MeV $<M_{A'}<$ 22.5 MeV. The proposed experimental setup and the analysis technique is discussed.

hep-ex↗

Vectorial atomic magnetometer based on coherent transients of laser absorption in Rb vapor

We have designed and tested an atomic vectorial magnetometer based on the analysis of the coherent oscillatory transients in the transmission of resonant laser light through a Rb vapor cell. We show that the oscillation amplitudes at the Larmor frequency and its first harmonic are related through a simple formula to the angles determining the orientation of the magnetic field vector. The magnetometer was successfully applied to the measurement of the ambient magnetic field.

physics.atom-ph↗

The Air Microwave Yield (AMY) experiment - A laboratory measurement of the microwave emission from extensive air showers

The AMY experiment aims to measure the microwave bremsstrahlung radiation (MBR) emitted by air-showers secondary electrons accelerating in collisions with neutral molecules of the atmosphere. The measurements are performed using a beam of 510 MeV electrons at the Beam Test Facility (BTF) of Frascati INFN National Laboratories. The goal of the AMY experiment is to measure in laboratory conditions the yield and the spectrum of the GHz emission in the frequency range between 1 and 20 GHz. The final purpose is to characterise the process to be used in a next generation detectors of ultra-high energy cosmic rays. A description of the experimental setup and the first results are presented.

astro-ph.IM↗

The large-angle photon veto system for the NA62 experiment at the CERN SPS

The branching ratio (BR) for the decay K^+ \to π^+ν\barν is a sensitive probe for new physics. The NA62 experiment at the CERN SPS will measure this BR to within about 10%. To reject the background from dominant kaon decays with final state photons, the large-angle photon vetoes (LAVs) must detect photons of energy as low as 200 MeV with an inefficiency of less than 10^{-4}. The LAV detectors make use of lead glass blocks recycled from the OPAL electromagnetic calorimeter barrel. We describe the mechanical design and challenges faced during construction, the characterization of the lead glass blocks and solutions adopted for monitoring their performance, and the development of front-end electronics to allow simultaneous time and energy measurements over an extended dynamic range using the time over-threshold technique. Our results are based on test-beam data and are reproduced by a detailed Monte Carlo simulation that includes the readout chain.

physics.ins-det↗

Magnetometer suitable for Earth field measurement based on transient atomic response

We describe the development of a simple atomic magnetometer using $^{87}$Rb vapor suitable for Earth magnetic field monitoring. The magnetometer is based on time-domain determination of the transient precession frequency of the atomic alignment around the measured field. A sensitivity of 1.5 nT/$\sqrt{Hz}$ is demonstrated on the measurement of the Earth magnetic field in the laboratory. We discuss the different parameters determining the magnetometer precision and accuracy and predict a sensitivity of 30 pT/$\sqrt{Hz}$

physics.atom-ph↗

Characterization of a tagged $γ$-ray beam line at the DA$Φ$NE Beam Test Facility

At the core of the AGILE scientific instrument, designed to operate on a satellite, there is the Gamma Ray Imaging Detector (GRID) consisting of a Silicon Tracker (ST), a Cesium Iodide Mini-Calorimeter and an Anti-Coincidence system of plastic scintillator bars. The ST needs an on-ground calibration with a $γ$-ray beam to validate the simulation used to calculate the energy response function and the effective area versus the energy and the direction of the $γ$ rays. A tagged $γ$-ray beam line was designed at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali of Frascati (LNF), based on an electron beam generating $γ$ rays through bremsstrahlung in a position-sensitive target. The $γ$-ray energy is deduced by difference with the post-bremsstrahlung electron energy \cite{prest}-\cite{hasan}. The electron energy is measured by a spectrometer consisting of a dipole magnet and an array of position sensitive silicon strip detectors, the Photon Tagging System (PTS). The use of the combined BTF-PTS system as tagged photon beam requires understanding the efficiency of $γ$-ray tagging, the probability of fake tagging, the energy resolution and the relation of the PTS hit position versus the $γ$-ray energy. This paper describes this study comparing data taken during the AGILE calibration occurred in 2005 with simulation.

physics.ins-det↗

First results about on-ground calibration of the Silicon Tracker for the AGILE satellite

The AGILE scientific instrument has been calibrated with a tagged $γ$-ray beam at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF). The goal of the calibration was the measure of the Point Spread Function (PSF) as a function of the photon energy and incident angle and the validation of the Monte Carlo (MC) simulation of the silicon tracker operation. The calibration setup is described and some preliminary results are presented.

astro-ph.IM↗

The NA62 LAV front-end electronics

The branching ratio for the decay $K^+ \to π^+ν\barν$ is sensitive to new physics; the NA62 experiment will measure it to within about 10%. To reject the dominant background from channels with final state photons, the large-angle vetoes (LAVs) must detect particles with better than 1 ns time resolution and 10% energy resolution over a very large energy range. Our custom readout board uses a time-over-threshold discriminator coupled to a TDC as a straightforward solution to satisfy these requirements. A prototype of the readout system was extensively tested together with the ANTI-A2 large angle veto module at CERN in summer 2010.

physics.ins-det↗

The Large-Angle Photon Veto System for the NA62 Experiment at CERN

The branching ratio (BR) for the decay K^+ \rightarrow π^+ ν\barν is a sensitive probe for new physics. The NA62 experiment at the CERN SPS will measure this BR to within about 10%. To reject the dominant background from channels with final state photons, the large-angle vetoes (LAVs) must detect photons of energy as low as 200 MeV with an inefficiency of less than 10^-4, as well as provide energy and time measurements with resolutions of 10% and 1 ns for 1 GeV photons. The LAV detectors make creative reuse of lead glass blocks recycled from the OPAL electromagnetic calorimeter barrel. We describe the mechanical design and challenges faced during construction, the characterization of the lead glass blocks and solutions adopted for monitoring their performance, and the development of front-end electronics to allow simultaneous time and energy measurements over an extended dynamic range using the time-over-threshold technique. Our results are based on test-beam data and are reproduced by a detailed Monte Carlo simulation that includes the readout chain.

physics.ins-det↗

Polarization squeezing of light by single passage through an atomic vapor

We have studied relative-intensity fluctuations for a variable set of orthogonal elliptic polarization components of a linearly polarized laser beam traversing a resonant $^{87}$Rb vapor cell. Significant polarization squeezing at the threshold level (-3dB) required for the implementation of several continuous variables quantum protocols was observed. The extreme simplicity of the setup, based on standard polarization components, makes it particularly convenient for quantum information applications.

quant-ph↗

Vibrational excitation induced by electron beam and cosmic rays in normal and superconductive aluminum bars

We report new measurements of the acoustic excitation of an Al5056 superconductive bar when hit by an electron beam, in a previously unexplored temperature range, down to 0.35 K. These data, analyzed together with previous results of the RAP experiment obtained for T > 0.54 K, show a vibrational response enhanced by a factor 4.9 with respect to that measured in the normal state. This enhancement explains the anomalous large signals due to cosmic rays previously detected in the NAUTILUS gravitational wave detector.

gr-qc↗

The UA9 experimental layout

The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode. Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam. Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Roman pots are installed in the path of the deflected particles and are equipped with a Medipix detector to reconstruct the transverse distribution of the impinging beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.

physics.acc-ph↗

Measurement of the $η\to 3π^{0}$ slope parameter $α$ with the KLOE detector

We present a measurement of the slope parameter $α$ for the $η\to 3π^{0}$ decay, with the KLOE experiment at the DA$Φ$NE $ϕ$-factory, based on a background free sample of $\sim$ 17 millions $η$ mesons produced in $ϕ$ radiative decays. By fitting the event density in the Dalitz plot we determine $α= -0.0301 \pm 0.0035\,stat\;_{-0.0035}^{+0.0022}\,syst\,$. The result is in agreement with recent measurements from hadro- and photo-production experiments.

hep-ex↗

Multi-GeV Electron Spectrometer

The advance in laser plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1pC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction of such a device. We will present the design considerations for this spectrometer and the first results from a prototype.

physics.ins-det↗

Measurement of the luminosity at the DAFNE collider upgraded with the crab waist scheme

The test of the crab waist collision scheme, undergoing at the e+e- Frascati DAFNE accelerator complex since February 2008, requires a fast and accurate measurement of the absolute luminosity, as well as a full characterization of the background conditions. Three different monitors, a Bhabha calorimeter, a Bhabha GEM tracker and a gamma bremsstrahlung proportional counter have been designed, tested and installed around the interaction point end of 2007-beginning of 2008. In this paper, we describe these detectors and present their performances in various operation conditions during the 2008 and 2009 DAFNE runs.

hep-ex↗

A global fit to determine the pseudoscalar mixing angle and the gluonium content of the eta' meson

We update the values of the eta-eta' mixing angle and of the eta' gluonium content by fitting our measurement R_phi = BR(phi to eta' gamma)/ BR(phi to eta gamma) together with several vector meson radiative decays to pseudoscalars (V to P gamma), pseudoscalar mesons radiative decays to vectors (P to V gamma) and the eta' to gamma gamma, pi^0 to gamma gamma widths. From the fit we extract a gluonium fraction of Z^2_G = 0.12 +- 0.04, the pseudoscalar mixing angle psi_P = (40.4 +- 0.6) degree and the phi-omega mixing angle psi_V = (3.32 +- 0.09) degree. Z^2_G and psi_P are fairly consistent with those previously published. We also evaluate the impact on the eta' gluonium content determination of future experimental improvements of the eta' branching ratios and decay width.

hep-ph↗

Search for the decay phi -> K0 K0bar gamma with the KLOE experiment

We have searched for the decay phi -> K0 K0bar gamma, by detecting K_s pairs plus a photon and with the K_s-mesons decaying to pi^+ pi^-, in a sample of about 1.5x 10^9 phi-decays collected by the KLOE experiment at DAFNE. The reaction proceeds through the intermediate states f_0(980) gamma, a_0(980) gamma. We find five events with 3.2 events expected from background processes. We obtain the upper limit: BR (phi -> K0 K0bar gamma) < 1.9x10^-8 at 90% C.L. .

hep-ex↗