SearcharxivSearch

arXiv subjects

P. W. Cattaneo

Publications and source records attributed to P. W. Cattaneo.

At least 19 recordsLinked to original sources

New limit on the μ+->e+γdecay with the MEG II experiment

This letter reports the result of the search for the decay μ+->e+γundertaken at the Paul Scherrer Institut in Switzerland with the MEG II experiment using the data collected in the 2021- 2022 physics runs. The sensitivity of this search is 2.2x10-13, a factor of 2.4 better than that of the full MEG dataset and obtained in a data taking period of about one fourth that of MEG, thanks to the superior performances of the new detector. The result is consistent with the expected background, yielding an upper limit on the branching ratio of B(μ+->e+γ)<1.5 x 10-13 (90 % C.L.). Additional improvements are expected with the data collected during the years 2023-2024. The data-taking will continue in the coming years.

hep-ex

Search for the X17 particle in $^{7}\mathrm{Li}(\mathrm{p},\mathrm{e}^+ \mathrm{e}^{-}) ^{8}\mathrm{Be}$ processes with the MEG II detector

The observation of a resonance structure in the opening angle of the electron-positron pairs in the $^{7}$Li(p,\ee) $^{8}$Be reaction was claimed and interpreted as the production and subsequent decay of a hypothetical particle (X17). Similar excesses, consistent with this particle, were later observed in processes involving $^{4}$He and $^{12}$C nuclei with the same experimental technique. The MEG II apparatus at PSI, designed to search for the $μ^+ \rightarrow \mathrm{e}^+ γ$ decay, can be exploited to investigate the existence of this particle and study its nature. Protons from a Cockroft-Walton accelerator, with an energy up to 1.1 MeV, were delivered on a dedicated Li-based target. The $γ$ and the e$^{+}$e$^{-}$ pair emerging from the $^8\mathrm{Be}^*$ transitions were studied with calorimeters and a spectrometer, featuring a broader angular acceptance than previous experiments. We present in this paper the analysis of a four-week data-taking in 2023 with a beam energy of 1080 keV, resulting in the excitation of two different resonances with Q-value \SI{17.6}{\mega\electronvolt} and \SI{18.1}{\mega\electronvolt}. No significant signal was found, and limits at \SI{90}{\percent} C.L. on the branching ratios (relative to the $γ$ emission) of the two resonances to X17 were set, $R_{17.6} < 1.8 \times 10^{-6} $ and $R_{18.1} < 1.2 \times 10^{-5} $.

nucl-ex

AGILE gamma-ray detection of the exceptional GRB 221009A

Gamma-ray emission in the MeV-GeV range from explosive cosmic events is of invaluable relevance to understanding physical processes related to the formation of neutron stars and black holes. Here we report on the detection by the AGILE satellite in the MeV-GeV energy range of the remarkable long-duration gamma-ray burst GRB 221009A. The AGILE onboard detectors have good exposure to GRB 221009A during its initial crucial phases. Hard X-ray/MeV emission in the prompt phase lasted hundreds of seconds, with the brightest radiation being emitted between 200 and 300 seconds after the initial trigger. Very intense GeV gamma-ray emission is detected by AGILE in the prompt and early afterglow phase up to 10,000 seconds. Time-resolved spectral analysis shows time-variable MeV-peaked emission simultaneous with intense power-law GeV radiation that persists in the afterglow phase. The coexistence during the prompt phase of very intense MeV emission together with highly nonthermal and hardening GeV radiation is a remarkable feature of GRB 221009A. During the prompt phase, the event shows spectrally different MeV and GeV emissions that are most likely generated by physical mechanisms occurring in different locations. AGILE observations provide crucial flux and spectral gamma-ray information regarding the early phases of GRB 221009A during which emission in the TeV range was reported.

astro-ph.HE

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

physics.ins-det

A search for $μ^+\to e^+γ$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($μ^+\to e^+γ$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

hep-ex

Multi-wavelength observations of the lensed quasar PKS 1830$-$211 during the 2019 $γ$-ray flare

PKS 1830$-$211 is a $γ$-ray emitting, high-redshift (z $= 2.507 \pm 0.002$), lensed flat-spectrum radio quasar. During the period mid-February to mid-April 2019, this source underwent a series of strong $γ$-ray flares that were detected by both AGILE-GRID and Fermi-LAT, reaching a maximum $γ$-ray flux of $F_{\rm E>100 MeV}\approx 2.3\times10^{-5}$ ph cm$^{-2}$ s$^{-1}$. Here we report on a coordinated campaign from both on-ground (Medicina, OVRO, REM, SRT) and orbiting facilities (AGILE, Fermi, INTEGRAL, NuSTAR, Swift, Chandra), with the aim of investigating the multi-wavelength properties of PKS 1830$-$211 through nearly simultaneous observations presented here for the first time. We find a possible break in the radio spectra in different epochs above 15 GHz, and a clear maximum of the 15 GHz data approximately 110 days after the $γ$-ray main activity periods. The spectral energy distribution shows a very pronounced Compton dominance (> 200) which challenges the canonical one-component emission model. Therefore we propose that the cooled electrons of the first component are re-accelerated to a second component by, e.g., kink or tearing instability during the $γ$-ray flaring periods. We also note that PKS 1830$-$211 could be a promising candidate for future observations with both Compton satellites (e.g., e-ASTROGAM) and Cherenkov arrays (CTAO) which will help, thanks to their improved sensitivity, in extending the data availability in energy bands currently uncovered.

astro-ph.HE

The CaloCube calorimeter for high-energy cosmic-ray measurements in space: performance of a large-scale prototype

The direct observation of high-energy cosmic rays, up to the PeV energy region, will increasingly rely on highly performing calorimeters, and the physics performance will be primarily determined by their geometrical acceptance and energy resolution. Thus, it is extremely important to optimize their geometrical design, granularity and absorption depth, with respect to the totalmass of the apparatus, which is amongst the most important constraints for a space mission. CaloCube is an homogeneous calorimeter whose basic geometry is cubic and isotropic, obtained by filling the cubic volume with small cubic scintillating crystals. In this way it is possible to detect particles arriving from every direction in space, thus maximizing the acceptance. This design summarizes a three-year R&D activity, aiming to both optimize and study the full-scale performance of the calorimeter, in the perspective of a cosmic-ray space mission, and investigate a viable technical design by means of the construction of several sizable prototypes. A large scale prototype, made of a mesh of 5x5x18 CsI(Tl) crystals, has been constructed and tested on high-energy particle beams at CERN SPS accelerator. In this paper we describe the CaloCube design and present the results relative to the response of the large scale prototype to electrons.

physics.ins-det

AGILE Observations of Fast Radio Bursts

We report on a systematic search for hard X-ray and gamma-ray emission in coincidence with fast radio bursts (FRBs) observed by the AGILE satellite. We used 13 years of AGILE archival data searching for time coincidences between exposed FRBs and events detectable by the MCAL (0.4-100 MeV) and GRID (50 MeV-30 GeV) detectors at timescales ranging from milliseconds to days/weeks. The current AGILE sky coverage allowed us to extend the search for high-energy emission preceding and following the FRB occurrence. We considered all FRBs sources currently included in catalogues, and identified a sub-sample (15 events) for which a good AGILE exposure either with MCAL or GRID was obtained. In this paper we focus on non-repeating FRBs, compared to a few nearby repeating sources. We did not detect significant MeV or GeV emission from any event. Our hard X-ray upper limits (ULs) in the MeV energy range were obtained for timescales from sub-millisecond to seconds, and in the GeV range from minutes to weeks around event times. We focus on a sub-set of 5 non-repeating and 2 repeating FRB sources whose distances are most likely smaller than that of 180916.J0158+65 (150 Mpc). For these sources, our MeV ULs translate into ULs on the isotropically-emitted energy of about 3x10^46 erg, comparable to that observed in the 2004 giant flare from the Galactic magnetar SGR 1806-20. On average, these nearby FRBs emit radio pulses of energies significantly larger than the recently detected SGR 1935+2154 and are not yet associated with intense MeV flaring.

astro-ph.HE

Search for lepton flavour violating muon decay mediated by a new light particle in the MEG experiment

We present the first direct search for lepton flavour violating muon decay mediated by a new light particle X, $μ^+ \to \mathrm{e}^+\mathrm{X}, \mathrm{X} \to γγ$. This search uses a dataset resulting from $7.5\times 10^{14}$ stopped muons collected by the MEG experiment at the Paul Scherrer Institut in the period 2009--2013. No significant excess is found in the mass region 20--45 MeV/c$^2$ for lifetimes below 40 ps, and we set the most stringent branching ratio upper limits in the mass region of 20--40 MeV/c$^2$, down to $\mathcal{O}(10^{-11})$ at 90\% confidence level.

hep-ex

Timing resolution of a plastic scintillator counter read out by radiation damaged SiPMs connected in series

This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 \times 40 \times5~\mathrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for different combinations of SiPMs at various levels of irradiation. Firstly, six SiPMs were equally irradiated with electrons from $^{90}$Sr sources up to a fluence of $Φ_\mathrm{e^-}\approx 3 \times 10^{12}~\mathrm{cm}^{-2}$. The timing resolution of the counter gradually deteriorated by the increase in dark current. The dark current and the deterioration were reduced when the counter was cooled from 30$^\circ$C to 10$^\circ$C. Secondly, 33 SiPMs were irradiated with reactor neutrons. The characteristics of counters read out by series-connected SiPMs with non-uniform damage levels, were investigated. The signal pulse height, the time response, and the timing resolution depend on the hit position in the counter, when SiPMs' irradiation is not uniform.

physics.ins-det

Characterization of Hamamatsu 14160 series of Silicon Photo-Multipliers

Silicon Photo-Multipliers (SiPMs) are semiconductor-based photo-detectors with performances similar to the traditional Photo-Multiplier Tubes (PMTs). An increasing number of experiments dedicated to particle detection in colliders, accelerators, astrophysics, neutrino and rare-event physics involving scintillators are using SiPMs as photodetectors. They are gradually substituting PMTs in many applications, especially where low voltages are required and high magnetic field is present. Hamamatsu Photonics K.K., one of leading producers of photo-detectors, in the last year introduced the S14160 series of SiPMs with improved performances. In this work, a characterization of these devices will be presented in terms of breakdown voltages, pulse shape, dark current and gain. Particular attention has been dedicated to the analysis of the parameters as function of temperature.

physics.ins-det

AGILESim: Monte Carlo simulation of the AGILE gamma-ray telescope

The accuracy of Monte Carlo simulations in reproducing the scientific performance of space telescopes (e.g. angular resolution) is mandatory for a correct design of the mission. A brand-new Monte Carlo simulator of the Astrorivelatore Gamma ad Immagini LEggero (AGILE)/Gamma-Ray Imaging Detector (GRID) space telescope, AGILESim, is built using the customizable Bologna Geant4 Multi-Mission Simulator (BoGEMMS) architecture and the latest Geant4 library to reproduce the instrument performance of the AGILE/GRID instrument. The Monte Carlo simulation output is digitized in the BoGEMMS postprocessing pipeline, according to the instrument electronic read-out logic, then converted into the onboard data handling format, and finally analyzed by the standard mission on-ground reconstruction pipeline, including the Kalman filter, as a real observation in space. In this paper we focus on the scientific validation of AGILESim, performed by reproducing (i) the conversion efficiency of the tracker planes, (ii) the tracker charge readout distribution measured by the on-ground assembly, integration, and verification activity, and (iii) the point-spread function of in-flight observations of the Vela pulsar in the 100 MeV - 1 GeV energy range. We measure an in-flight angular resolution (FWHM) for Vela-like point sources of $2.0^{+0.2}_{-0.3}$ and $0.8^{+0.1}_{-0.1}$ degrees in the 100 - 300 and 300 - 1000 MeV energy bands, respectively. The successful cross-comparison of the simulation results with the AGILE on-ground and in-space performance validates the BoGEMMS framework for its application to future gamma-ray trackers (e.g. e-ASTROGAM and AMEGO).

astro-ph.IM

An X-Ray Burst from a Magnetar Enlightening the Mechanism of Fast Radio Bursts

Fast radio bursts (FRBs) are short (millisecond) radio pulses originating from enigmatic sources at extragalactic distances so far lacking a detection in other energy bands. Magnetized neutron stars (magnetars) have been considered as the sources powering the FRBs, but the connection is controversial because of differing energetics and the lack of radio and X-ray detections with similar characteristics in the two classes. We report here the detection by the AGILE satellite on April 28, 2020 of an X-ray burst in coincidence with the very bright radio burst from the Galactic magnetar SGR 1935+2154. The burst detected by AGILE in the hard X-ray band (18-60 keV) lasts about 0.5 seconds, it is spectrally cutoff above 80 keV, and implies an isotropically emitted energy ~ $10^{40}$ erg. This event is remarkable in many ways: it shows for the first time that a magnetar can produce X-ray bursts in coincidence with FRB-like radio bursts; it also suggests that FRBs associated with magnetars may emit X-ray bursts of both magnetospheric and radio-pulse types that may be discovered in nearby sources. Guided by this detection, we discuss SGR 1935+2154 in the context of FRBs, and especially focus on the class of repeating-FRBs. Based on energetics, magnetars with fields B ~ $10^{15}$ G may power the majority of repeating-FRBs. Nearby repeating-FRBs offer a unique occasion to consolidate the FRB-magnetar connection, and we present new data on the X-ray monitoring of nearby FRBs. Our detection enlightens and constrains the physical process leading to FRBs: contrary to previous expectations, high-brightness temperature radio emission coexists with spectrally-cutoff X-ray radiation.

astro-ph.HE

Beam test characterisation of a Plastic Scintillator Prototype for the space-based cosmic ray experiment HERD

The High Energy cosmic-Radiation Detector (HERD) facility is planned to go onboard China's Space Station, planned to be operational starting in around 2025 for about 10 years. The main scientific objectives of HERD are the search for signals of dark matter annihilation products, precise cosmic electron/positron spectrum and measurements of anisotropy up to 10 TeV, precise cosmic ray spectrum and composition measurements up to the knee energy (1 PeV), and high energy $γ$-ray monitoring and survey. HERD consists of a 3D cubic crystals calorimeter (CALO) surrounded by microstrip silicon trackers (STKs) and scintillating fiber trackers (FIT) and by a Plastic Scintillator Detector (PSD) for $γ$-ray veto and ion charge measurement. A PSD prototype consisting of a scintillator tile readout by two arrays of SiPMs on opposite sides has been tested with proton and C ion beam at the CNAO (Centro Nazionale Adroterapia Oncologica) in Pavia, (Italy). Preliminary results on charge resolution are presented.

physics.ins-det

Gamma-Ray and X-Ray Observations of the Periodic-Repeater FRB 180916 During Active Phases

FRB 180916 is a most intriguing source at 150 Mpc distance capable of producing repeating fast radio bursts with a periodic 16.35 day temporal pattern. We report on the X-ray and $γ$-ray observations of FRB 180916 obtained by AGILE and Swift. We focused on the recurrent 5-day time intervals of active radio bursting and present results obtained on Feb. 3 - 8; Feb. 25; Mar. 5 - 10; Mar. 22 - 28, 2020 during a multiwavelength campaign involving high-energy and radio observations. We also searched for temporal coincidences at millisecond timescales between all known radio bursts of FRB 180916 and X-ray and MeV events detectable by AGILE. We do not detect any simultaneous event or any extended X-ray and $γ$-ray emission on timescales of hours/days/weeks. Our cumulative X-ray (0.3-10 keV) flux upper limit of $5 \times\,10^{-14} \rm \, erg \, cm^{-2} s^{-1}$ (obtained during 5-day active intervals) translates into an isotropic luminosity upper limit of $L_{X,UL} \sim 1.5 \times\, 10^{41} \rm erg \, s^{-1}$. Observations above 100 MeV over a many-year timescale provide an average luminosity upper limit one order of magnitude larger. These results provide the so-far most stringent limits on high-energy emission from FRB 180916 and constrain the dissipation of magnetic energy from a magnetar-like source of radius $R_m$, internal magnetic field $B_m$ and dissipation timescale $τ_d$ to satisfy the relation $R_{m,6}^3 B_{m,16}^2 τ_{d,8}^{-1} \lesssim 1$, where $R_{m,6}$ is $R_m$ in units of $10^6$ cm, $B_{m,16}$ is $B_m$ in units of $10^{16}$ G, and $τ_{d,8}$ in units of $10^8$ s.

astro-ph.HE

AGILE Observations of Two Repeating Fast Radio Bursts with Small Intrinsic Dispersion Measures

We focus on two repeating fast radio bursts (FRBs) recently detected by the CHIME/FRB experiment in 2018--2019 (Source 1: 180916.J0158+65, and Source 2: 181030.J1054+73). These sources have low excess dispersion measures (DMs) ($ < 100 \rm \, pc \, cm^{-3}$ and $ < 20 \rm \, pc \, cm^{-3}$, respectively), implying relatively small maximal distances. They were repeatedly observed by AGILE in the MeV--GeV energy range. We do not detect prompt emission simultaneously with these repeating events. This search is particularly significant for the submillisecond and millisecond integrations obtainable by AGILE. The sources are constrained to emit a MeV-fluence in the millisecond range below $F'_{MeV} = 10^{-8} \, \rm erg \, cm^{-2}$ corresponding to an isotropic energy near $E_{MeV,UL} \simeq 2 \times 10^{46}\,$erg for a distance of 150 Mpc (applicable to Source 1). We also searched for $γ$-ray emission for time intervals up to 100 days, obtaining 3$\,σ$ upper limits (ULs) for the average isotropic luminosity above 50 MeV, $L_{γ,UL} \simeq \,$(5-10)$\,\times 10^{43} \rm \, erg \, s^{-1}$. For a source distance near 100 kpc (possibly applicable to Source 2), our ULs imply $E_{MeV,UL}\simeq10^{40} \rm erg$, and $L_{γ,UL} \simeq \,$2$\,\times 10^{37} \rm \, erg \, s^{-1}$. Our results are significant in constraining the high-energy emission of underlying sources such as magnetars, or other phenomena related to extragalactic compact objects, and show the prompt emission to be lower than the peak of the 2004 magnetar outburst of SGR 1806-20 for source distances less than about 100 Mpc.

astro-ph.HE

The laser-based time calibration system for the MEG II pixelated Timing Counter

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon photomultipliers (SiPMs). It is difficult to apply previous laser-based calibration methods for conventional meter-scale Time-Of-Flight detectors to the MEG II pTC from the implementation and the accuracy points of view. This paper presents a new laser-based time calibration system which can overcome such difficulties. A laser pulse is split into each scintillator counter via several optical components so that we can directly measure the time offset of each counter relative to the laser-emitted time. We carefully tested all the components and procedures prior to the actual operation. The laser system was installed into the pTC and thoroughly tested under the real experimental condition. The system showed good stability and being sensitive to any change of timing larger than ~10 ps. Moreover, it showed an uncertainty of 48 ps in the determination of the time offsets, which meets our requirements. The new method provides an example of the implementation of a precise timing alignment for the new type of detectors enabled by the advance of SiPM technology.

physics.ins-det

A Laser-based Time Calibration System for the MEG II Timing Counter

We have developed a new laser-based time calibration system for the MEG II timing counter dedicated to timing measurement of positrons. The detector requires precise timing alignment between $\sim\,$500 scintillation counters. In this study, we present the calibration system which can directly measure the time offset of each counter relative to the laser-synchronized pulse. We thoroughly tested all the optical components and the uncertainty of this method is estimated to be 24 ps. In 2017, we installed the full system into the MEG II environment and performed a commissioning run. This method shows excellent stability and consistency with another method. The proposed system provides a precise timing alignment for SiPM-based timing detectors. It also has potential in areas such as TOF-PET.

physics.ins-det