SearcharxivSearch

arXiv subjects

P.

Publications and source records attributed to P..

22 records · Page 2Linked to original sources

Analytical determination of the stop band tuning of photonic crystals infiltrated with liquid crystals

We demonstrate that the tuning of the optical properties of a photonic crystal infiltrated with liquid crystal can be calculate using the Von-Laue diffraction condition. We present a simple formula to predict the shift of the stop band for all the diffraction orders using an effective index of the composite structure. We consider that our formula is useful to determine in a simple manner the shift of the optical properties of tunable photonic crystals. We compare the accuracy of our method with calculations obtained with the Plane Wave Method.

physics.optics

Design, analysis, and testing of a microdot apodizer for the apodized pupil Lyot coronagraph (Research note). III. Application to extremely large telescopes

The apodized-pupil Lyot coronagraph is one of the most advanced starlight cancellation concepts studied intensively in the past few years. Extreme adaptive optics instruments built for present-day 8m class telescopes will operate with such coronagraph for imagery and spectroscopy of faint stellar companions. Following the development of an early demonstrator in the context of the VLT-SPHERE project (~2012), we manufactured and tested a second APLC prototype in microdots designed for extremely large telescopes. This study has been conducted in the context of the EPICS instrument project for the European-ELT (~2018), where a proof of concept is required at this stage. Our prototype was specifically designed for the European-ELT pupil, taking its large central obscuration ratio (30%) into account. Near-IR laboratory results are compared with simulations. We demonstrate good agreement with theory. A peak attenuation of 295 was achieved, and contrasts of 10^-5 and 10^-6 were reached at 7 and 12 lambda/D, respectively. We show that the APLC is able to maintain these contrasts with a central obscuration ratio of the telescope in the range 15% to 30%, and we report that these performances can be achieved in a wide wavelength bandpass (BW = 24%). In addition, we report improvement to the accuracy of the control of the local transmission of the manufactured microdot apodizer to that of the previous prototype. The local profile error is found to be less than 2%. The maturity and reproducibility of the APLC made with microdots is demonstrated. The apodized pupil Lyot coronagraph is confirmed to be a pertinent candidate for high-contrast imaging with ELTs.

astro-ph.IM

Determining the Physical Lens Parameters of the Binary Gravitational Microlensing Event MOA-2009-BLG-016

We report the result of the analysis of the light curve of the microlensing event MOA-2009-BLG-016. The light curve is characterized by a short-duration anomaly near the peak and an overall asymmetry. We find that the peak anomaly is due to a binary companion to the primary lens and the asymmetry of the light curve is explained by the parallax effect caused by the acceleration of the observer over the course of the event due to the orbital motion of the Earth around the Sun. In addition, we detect evidence for the effect of the finite size of the source near the peak of the event, which allows us to measure the angular Einstein radius of the lens system. The Einstein radius combined with the microlens parallax allows us to determine the total mass of the lens and the distance to the lens. We identify three distinct classes of degenerate solutions for the binary lens parameters, where two are manifestations of the previously identified degeneracies of close/wide binaries and positive/negative impact parameters, while the third class is caused by the symmetric cycloid shape of the caustic. We find that, for the best-fit solution, the estimated mass of the lower-mass component of the binary is (0.04 +- 0.01) M_sun, implying a brown-dwarf companion. However, there exists a solution that is worse only by Δχ^2 ~ 3 for which the mass of the secondary is above the hydrogen-burning limit. Unfortunately, resolving these two degenerate solutions will be difficult as the relative lens-source proper motions for both are similar and small (~ 1 mas/yr) and thus the lens will remain blended with the source for the next several decades.

astro-ph.SR

A Cold Neptune-Mass Planet OGLE-2007-BLG-368Lb: Cold Neptunes Are Common

We present the discovery of a Neptune-mass planet OGLE-2007-BLG-368Lb with a planet-star mass ratio of q=[9.5 +/- 2.1] x 10^{-5} via gravitational microlensing. The planetary deviation was detected in real-time thanks to the high cadence of the MOA survey, real-time light curve monitoring and intensive follow-up observations. A Bayesian analysis returns the stellar mass and distance at M_l = 0.64_{-0.26}^{+0.21} M_\sun and D_l = 5.9_{-1.4}^{+0.9} kpc, respectively, so the mass and separation of the planet are M_p = 20_{-8}^{+7} M_\oplus and a = 3.3_{-0.8}^{+1.4} AU, respectively. This discovery adds another cold Neptune-mass planet to the planetary sample discovered by microlensing, which now comprise four cold Neptune/Super-Earths, five gas giant planets, and another sub-Saturn mass planet whose nature is unclear. The discovery of these ten cold exoplanets by the microlensing method implies that the mass ratio function of cold exoplanets scales as dN_{\rm pl}/d\log q \propto q^{-0.7 +/- 0.2} with a 95% confidence level upper limit of n < -0.35 (where dN_{\rm pl}/d\log q \propto q^n). As microlensing is most sensitive to planets beyond the snow-line, this implies that Neptune-mass planets are at least three times more common than Jupiters in this region at the 95% confidence level.

astro-ph.EP