SearcharxivSearch

arXiv subjects

Paolo Falferi

Publications and source records attributed to Paolo Falferi.

13 recordsLinked to original sources

Search for post-inflationary QCD axions with a quantum-limited tunable microwave receiver

A search for cosmological axions has been performed by scanning a frequency region of $38\,$MHz centered at about $10.2\,$GHz, corresponding to an axion mass $m_a \simeq 42\,\mu$eV. The QUAX experimental apparatus, a haloscope comprised of a 1-liter volume tunable cavity immersed in an $8\,$T magnetic field and a quantum-limited detection chain, set limits on the axion-photon coupling at the $10^{-14}\,$GeV$^{-1}$ level. As no signal candidate has been observed, viable hadronic axion models are ruled out in a currently preferred post-inflationary region $m_a > 40\,\mu$eV.

hep-ex

Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers

Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation-effects that are not easily accommodated by simplistic linearized approaches

cond-mat.supr-con

Broadband parametric amplification in DARTWARS

Superconducting parametric amplifiers offer the capability to amplify feeble signals with extremely low levels of added noise, potentially reaching quantum-limited amplification. This characteristic makes them essential components in the realm of high-fidelity quantum computing and serves to propel advancements in the field of quantum sensing. In particular, Traveling-Wave Parametric Amplifiers (TWPAs) may be especially suitable for practical applications due to their multi-Gigahertz amplification bandwidth, a feature lacking in Josephson Parametric Amplifiers (JPAs), despite the latter being a more established technology. This paper presents recent developments of the DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project, focusing on the latest prototypes of Kinetic Inductance TWPAs (KITWPAs). The project aims to develop a KITWPA capable of achieving $20\,$ dB of amplification. To enhance the production yield, the first prototypes were fabricated with half the length and expected gain of the final device. In this paper, we present the results of the characterization of one of the half-length prototypes. The measurements revealed an average amplification of approximately $9\,$dB across a $2\,$GHz bandwidth for a KITWPA spanning $17\,$mm in length.

quant-ph

Development of KI-TWPAs for the DARTWARS project

Noise at the quantum limit over a broad bandwidth is a fundamental requirement for future cryogenic experiments for neutrino mass measurements, dark matter searches and Cosmic Microwave Background (CMB) measurements as well as for fast high-fidelity read-out of superconducting qubits. In the last years, Josephson Parametric Amplifiers (JPA) have demonstrated noise levels close to the quantum limit, but due to their narrow bandwidth, only few detectors or qubits per line can be read out in parallel. An alternative and innovative solution is based on superconducting parametric amplification exploiting the travelling-wave concept. Within the DARTWARS (Detector Array Readout with Travelling Wave AmplifieRS) project, we develop Kinetic Inductance Travelling-Wave Parametric Amplifiers (KI-TWPAs) for low temperature detectors and qubit read-out. KI-TWPAs are typically operated in a threewave mixing (3WM) mode and are characterised by a high gain, a high saturation power, a large amplification bandwidth and nearly quantum limited noise performance. The goal of the DARTWARS project is to optimise the KI-TWPA design, explore new materials, and investigate alternative fabrication processes in order to enhance the overall performance of the amplifier. In this contribution we present the advancements made by the DARTWARS collaboration to produce a working prototype of a KI-TWPA, from the fabrication to the characterisation.

quant-ph

Design and simulation of a transmon qubit chip for Axion detection

Quantum Sensing is a rapidly expanding research field that finds one of its applications in Fundamental Physics, as the search for Dark Matter. Devices based on superconducting qubits have already been successfully applied in detecting few-GHz single photons via Quantum Non-Demolition measurement (QND). This technique allows us to perform repeatable measurements, bringing remarkable sensitivity improvements and dark count rate suppression in experiments based on high-precision microwave photon detection, such as for Axions and Dark Photons search. In this context, the INFN Qub-IT project goal is to realize an itinerant single-photon counter based on superconducting qubits that will exploit QND for enhancing Axion search experiments. In this study, we present Qub-IT's status towards the realization of its first superconducting qubit device, illustrating design and simulation procedures and the characterization of fabricated Coplanar Waveguide Resonators (CPWs) for readout. We match target qubit parameters and assess a few-percent level agreement between lumped and distributed element simulation models. We reach a maximum internal quality factor of 9.2x10^5 for -92 dBm on-chip readout power.

quant-ph

High kinetic inductance NbTiN films for quantum limited travelling wave parametric amplifiers

A wide-bandwidth and low-noise amplification chain in the microwave regime is crucial for the efficient read-out of quantum systems based on superconducting detectors, such as Microwave Kinetic Inductance Detectors (MKIDs), Transition Edge Sensors (TESs), Magnetic Microcalorimeters (MMCs), and RF cavities, as well as qubits. Kinetic Inductance Travelling Wave Parametric Amplifiers (KI-TWPAs) operated in a three-wave mixing fashion have demonstrated exceptional dynamic range and low-noise performance, approaching the quantum limit. These amplifiers can be fabricated using a single layer of a high kinetic inductance film as weakly dispersive artificial transmission lines, with the ability to control the phase-matched bandwidth through dispersion engineering. In this study, we present the optimisation of the rf sputter-deposition process of NbTiN films using a Nb80%T20 target, with the goal of achieving precise control over film characteristics, resulting in high kinetic inductance while maintaining a high transition temperature. The parameter landscape related to the different sputtering conditions, such as pressure, power, and nitrogen flow, has been explored and the film thickness has been used as a fine-tuning parameter to adjust the properties of the final NbTiN films used for the fabrication of KI-TWPAs. As a final result, we have obtained a NbTiN film with a kinetic inductance of 8.5 pH/sq which we have exploited to fabricate KI-TWPA prototype devices, showing promising amplification performance.

physics.app-ph

The future search for low-frequency axions and new physics with the FLASH resonant cavity experiment at Frascati National Laboratories

We present a proposal for a new experiment, the FINUDA magnet for Light Axion SearcH (FLASH), a large resonant-cavity haloscope in a high static magnetic field which is planned to probe new physics in the form of dark matter (DM) axions, scalar fields, chameleons, hidden photons, as well as high frequency gravitational waves (GWs). Concerning the QCD axion, FLASH will search for these particles as the DM in the mass range (0.49-1.49) ueV, thus filling the mass gap between the ranges covered by other planned searches. A dedicated Microstrip SQUID operating at ultra-cryogenic temperatures will amplify the signal. The frequency range accessible overlaps with the Very High Frequency (VHF) range of the radio wave spectrum and allows for a search in GWs in the frequency range (100-300) MHz. The experiment will make use of the cryogenic plant and magnet of the FINUDA experiment at INFN Frascati National Laboratories near Rome (Italy); the operations needed to restore the functionalities of the apparatus are currently underway. We present the setup of the experiment and the sensitivity forecasts for the detection of axions, scalar fields, chameleons, hidden photons, and GWs.

physics.ins-det

Status of the SIMP Project: Toward the Single Microwave Photon Detection

The Italian institute for nuclear physics (INFN) has financed the SIMP project (2019-2021) in order to strengthen its skills and technologies in the field of meV detectors with the ultimate aim of developing a single microwave photon detector. This goal will be pursued by improving the sensitivity and the dark count rate of two types of photodetectors: current biased Josephson Junction (JJ) for the frequency range 10-50 GHz and Transition Edge Sensor (TES) for the frequency range 30-100 GHz. Preliminary results on materials and devices characterization are presented.

physics.ins-det

Development of highly sensitive nanoscale transition edge sensors for gigahertz astronomy and dark matter search

Terahertz and sub-terahertz band detection has a key role both in fundamental interactions physics and technological applications, such as medical imaging, industrial quality control and homeland security. In particular, transition edge sensors (TESs) and kinetic inductance detectors (KIDs) are the most employed bolometers and calorimeters in the THz and sub-THz band for astrophysics and astroparticles research. Here, we present the electronic, thermal and spectral characterization of an aluminum/copper bilayer sensing structure that, thanks to its thermal properties and a simple miniaturized design, could be considered a perfect candidate to realize an extremely sensitive class of nanoscale TES (nano-TES) for the giga-therahertz band. Indeed, thanks to the reduced dimensionality of the active region and the efficient Andreev mirror (AM) heat confinement, our devices are predicted to reach state-of-the-art TES performance. In particular, as a bolometer the nano-TES is expected to have a noise equivalent power (NEP) of $5\times10^{-20}$ W/$\sqrt{\mathrm{Hz}}$ and a relaxation time of $\sim 10$ ns for the sub-THz band, typical of cosmic microwave background studies. When operated as single-photon sensor, the devices are expected to show a remarkable frequency resolution of 100 GHz, pointing towards the necessary energy sensitivity requested in laboratory axion search experiments. Finally, different multiplexing schemes are proposed and sized for imaging applications.

cond-mat.mes-hall

Search for light scalar Dark Matter candidate with AURIGA detector

A search for a new scalar field, called moduli, has been performed using the cryogenic resonant-mass AURIGA detector. Predicted by string theory, moduli may provide a significant contribution to the dark matter (DM) component of our universe. If this is the case, the interaction of ordinary matter with the local DM moduli, forming the Galaxy halo, will cause an oscillation of solid bodies with a frequency corresponding to the mass of moduli. In the sensitive band of AURIGA, some $100\,\mathrm{Hz}$ at around $1\,\mathrm{kHz}$, the expected signal, with a $Q=\tfrac{\triangle f}{f}\sim10^{6}$, is a narrow peak, $\triangle f\sim1\,\mathrm{mHz}$. Here the detector strain sensitivity is $h_{s}\sim2\times10^{-21}\,\mathrm{Hz^{-1/2}}$, within a factor of $2$. These numbers translate to upper limits at $95\%\,C.L.$ on the moduli coupling to ordinary matter $d_{e}\lesssim10^{-5}$ around masses $m_ϕ=3.6\cdot10^{-12}\,\mathrm{eV}$, for the standard DM halo model with $ρ_{DM}=0.3\,\mathrm{GeV/cm^{3}}$.

hep-ex

The QUAX-g_p g_s experiment to search for monopole-dipole Axion interaction

The QCD axion is an hypothetical particle introduced to solve the strong CP problem of standard model of particle physics and is of interest as a possible component of cold dark matter. In the axion scenario, J.E. Moody and F. Wilczek showed that a new macroscopic long-range force, mediated by axion exchange, acts on electron spins, and that such force can be described in terms of an effective magnetic field. The QUAX-g$_p$g$_s$ experiment, carried out at INFN Laboratori Nazionali di Legnaro, is designed to search for the effects on magnetized samples of the effective field produced by unpolarized mass sources. As this field is macroscopic, it can be detected by measuring the change of magnetization of a paramagnetic Gadolinium silicate (GSO) crystal cooled at liquid helium temperature. The axion effective field induced magnetization can be detected with a SQUID magnetometer. By varying the position of the of source masses, the induced GSO magnetization is modulated at acoustic frequencies. Although the full QUAX-g$_p$g$_s$ sensitivity has not been yet exploited, we are able to measure a magnetization of $10^{-17}~$T at few tens of Hz. With this sensitivity we expect to further improve the upper limit of the coupling of the predicted long-range force in the $10^{-3}$ to $1~$m interval.

physics.ins-det

Feedback-enhanced parametric squeezing of mechanical motion

We present a single-quadrature feedback scheme able to overcome the conventional 3 dB limit on parametric squeezing. The method is experimentally demonstrated in a micromechanical system based on a cantilever with a magnetic tip. The cantilever is detected at low temperature by a SQUID susceptometer, while parametric pumping is obtained by modulating the magnetic field gradient at twice the cantilever frequency. A maximum squeezing of 11.5 dB and 11.3 dB is observed, respectively in the response to a sinusoidal test signal and in the thermomechanical noise. The maximum squeezing factor is limited only by the maximum achievable parametric modulation. The proposed technique can be used to squeeze one quadrature of a mechanical resonator below the quantum noise level, even without the need for a quantum limited detector.

cond-mat.mes-hall

Principles of wide bandwidth acoustic detectors and the single-mass DUAL detector

We apply the standard theory of the elastic body to obtain a set of equations describing the behavior of an acoustic Gravitational Wave detector, fully taking into account the 3-dimensional properties of the mass, the readout and the signal. We show that the advantages given by a Dual detector made by two nested oscillators can also be obtained by monitoring two different acoustic modes of the same oscillator, thus easing the detector realization. We apply these concepts and by means of an optimization process we derive the main figures of such a single-mass Dual detector designed specifically for the frequency interval 2-5kHz. Finally we calculate the SQL sensitivity of this detector.

gr-qc