SearcharxivSearch

arXiv subjects

Pascal Isenring

Publications and source records attributed to Pascal Isenring.

4 recordsLinked to original sources

High-Resolution Timing for Vertex-Reconstructed Muon-Spin Spectroscopy Using Plastic Scintillators and MuTRiG

Vertex-reconstructed muon-spin spectroscopy (vx-{\mu}SR) based on silicon pixel detectors has recently demonstrated unprecedented lateral resolution and operation at muon stop rates exceeding 400 kHz. However, the intrinsic timing resolution of current silicon pixel detector technology limits the accessible frequency range and restricts {\mu}SR measurements with fast relaxation rates. In this work, we report on the integration of plastic scintillator detectors (PSD) read out with the MuTRiG ASIC into the MuSiP vx-{\mu}SR spectrometer. This complements the spatial resolution achieved by using silicon pixel detectors with high-precision timing information for incoming muons and decay positrons. We demonstrate stable operation of MuTRiG in vacuum and achieve sub-300 ps time resolution after time-walk correction. Standard transverse-field {\mu}SR measurements on a SiO$_2$ sample confirm that the combined MuTRiG-PSD system resolves precession frequencies beyond 50 MHz, far exceeding the capabilities of silicon pixel detectors alone. These results establish a viable and scalable path towards high-rate, high-resolution {\mu}SR with both excellent spatial and temporal performance.

physics.ins-det

The effect of magnetic fields on vertex reconstructed muon-spin spectroscopy

The use of a Si pixel-based particle tracking scheme in muSR will, among others, allow measurements using a ten-fold increased stopped muons rate and samples ten times smaller than currently possible. Here we present simulation results to assess the effects of magnetic fields on two spectrometer configurations using a two-layered tracking scheme for the incoming and outgoing particles. At a low magnetic field of up to ~50 mT, the tracking and reconstruction accuracy is only minimally influenced. Beyond a magnetic field of ~80 mT the tracking capabilities diminish significantly. Operating a two-layered scheme using small magnetic fields hence does not require adaptations. Only at large magnetic fields, a tracking scheme that makes use of an accurate field map or the use of at least three layers must be employed to achieve reliable particle tracking.

physics.ins-det

New Frontiers in Muon-Spin Spectroscopy Using Si-Pixel Detectors

The study of novel quantum materials relies on muon-spin rotation, relaxation, or resonance (\mSR) measurements. Yet, a fundamental limitation persists: many of these materials can only be synthesized in extremely small quantities, often at sub-millimeter scales. While \mSR ~offers unique insights into electronic and magnetic properties, existing spectrometers lack a sub-millimeter spatial resolution and the possibility of triggerless pump-probe data acquisition, which would enable more advanced measurements. The General Purpose Surface-muon instrument (GPS) at the Paul Scherrer Institute (PSI) is currently limited to a muon stopping rate of \SI{40}{\kilo\hertz} to \SI{120}{\kilo\hertz}, a constraint that will become more pressing with the upcoming High-Intensity Muon Beam (HIMB) project. To overcome these challenges, we demonstrate the feasibility of employing ultra-thin monolithic Si-pixel detectors to reconstruct the stopping position of muons within the sample, thereby significantly enhancing the capability of measuring at higher muon rate. Additionally, we explore the first steps toward a triggerless pump-probe \mSR ~measurement scheme. Unlike conventional pump-probe techniques that require external triggers, a triggerless readout system can continuously integrate stimuli pulses into the data stream, allowing real-time tracking of ultra-fast dynamics in quantum materials. This approach will enable the study of transient states, spin dynamics, and quantum coherence under external stimuli.

physics.ins-det

Advanced muon-spin spectroscopy with high lateral resolution using Si-pixel detectors

Muon-spin spectroscopy at continuous sources has stagnated at a stopped muons rate of ~40 kHz for the last few decades. The major limiting factor is the requirement of a single muon in the sample during the typical 10 {\mu}s data gate window. To overcome this limit and to be able to perform muon-spin relaxation ({\mu}SR) measurements on millimeter-sized samples, one can use vertex reconstruction methods to construct {\mu}SR spectra. This is now possible thanks to the availability of very thin monolithic Si-pixel chips, which offer minimal particle scattering and high count rate. Here we present results from a Si-pixel based spectrometer that utilizes vertex reconstruction schemes for the incoming muons and emitted positrons. With this spectrometer we were able to obtain a first vertex reconstructed {\mu}SR (VR-{\mu}SR) spectrum. The unique capabilities and benefits of such a spectrometer are discussed.

physics.ins-det