SearcharxivSearch

arXiv subjects

Pascal V. Grundler

Publications and source records attributed to Pascal V. Grundler.

2 recordsLinked to original sources

Terbium-149 PET/CT: First Quantitative Imaging with a Clinical Long-Axial Field-of-View Scanner

Introduction: Terbium-149 ($^{149}$Tb) is a promising radionuclide for targeted $\alpha$ therapy that has a non-zero branching ratio (BR) for positron decay. However, its relatively low positron branching fraction and multiple prompt $\gamma$ emissions may challenge quantitative imaging. This study evaluates, for the first time, the imaging performance and quantitative accuracy of $^{149}$Tb using a clinical long axial field-of-view (LAFOV) PET/CT system. Methods: Quantitative accuracy of $^{149}$Tb was assessed with a NEMA IEC body phantom, which was filled with about 45 MBq $^{149}$Tb and a sphere-to-background ration of 10:1. The phantom was scanned for 20 min and shorter scan times and lower activities were simulated. Recovery coefficients, coefficient of variation, and lung residual error were evaluated for different reconstruction settings and compared to the EARL standard 2 for $^{18}$F. Results: High-quality PET images of $^{149}$Tb were obtained, even with a simulated total activity of 4.5 MBq. The 20 min and full activity scan yielded a mean recovery coefficient $RC_\textit{mean}$ of $0.55$, $0.69$, $0.73$, $0.76$, $0.79$, and $0.81$ for the six phantom spheres. Despite the low count statistics, the coefficient of variation stays mostly below $15\,\%$. Relative scatter correction combined with prompt $\gamma$ modeling provided robust quantification. Conclusion: $^{149}$Tb can be imaged using a commercial LAFOV PET/CT with a quantitative accuracy comparable to the EARL standard 2 for $^{18}$F. These findings demonstrate the feasibility of PET-based treatment verification and dosimetry for targeted $\alpha$ therapy with $^{149}$Tb.

physics.med-ph

First Positronium Lifetime Imaging with Scandium-44 on a Long Axial Field-of-view PET/CT

Purpose: 44Sc has been successfully produced, synthesized, labeled and first-in-human studies were conducted some years ago. The decay properties of 44Sc, together with being close to a clinical implementation, make it an ideal candidate for in vivo positronium lifetime measurements. In this study, we investigate the count statistics for ortho-positronium (oPs) measurements with 44Sc. Method: A NEMA image quality phantom was filled with 41.7 MBq of 44Sc dissolved in water and scanned on a commercial long-axial field-of-view PET/CT. Three-photon events were identified using a prototype feature of the scanner and dedicated software. The lifetime of oPs was determined in the phantom spheres and in 4x4x4 mm^3 voxels. Results: All measured oPs lifetimes are compatible, within the uncertainties, with the literature values for water. The oPs lifetime is 2.65+-0.50, 1.39+-0.20 and 1.76+-0.18 ns in the three smallest spheres of the phantom and 1.79+-0.57 ns for a single voxel in the central region of the largest sphere. The relative standard deviation in the background regions of the time difference distributions, i.e., for time differences smaller than -2.7 ns, is above 20% - even for voxels inside the phantom spheres. Conclusions: Despite the favorable physical properties of 44Sc, the count statistics of three-photon events remains a challenge. The high prompt-photon energy causes a significant amount of random three-photon coincidences with the given methodology and, therefore, increases the statistical uncertainties on the measured oPs lifetime.

physics.med-ph