SearcharxivSearch

arXiv subjects

Patrice Salzenstein

Publications and source records attributed to Patrice Salzenstein.

7 recordsLinked to original sources

Self-powered smart contact lenses: a multidisciplinary approach to micro-scale energy and 900 MHz - 1.1 GHz bandwidth microfabricated loop antennas communication systems

Smart contact lenses are at the forefront of integrating microelectronics, biomedical engineering, and optics into wearable technologies. This work addresses a key obstacle in their development: achieving autonomous power without compromising safety or miniaturization. We examine energy harvesting strategies using intrinsic ocular sources-particularly tear salinity and eyelid motion-to enable sustainable operation without external batteries. The study emphasizes compact loop antennas operating between 900 MHz and 1.1 GHz as critical for wireless data transmission and power management. Material choices, signal integrity, and biocompatibility are also discussed. By presenting recent advances in 3D-printed optics, antenna integration, and energy systems, we propose a conceptual framework for the next generation of smart lenses, enabling real-time health monitoring and vision enhancement through self-powered, compact devices.

eess.SY

Uncertainty estimation on frequency shift of Brillouin light scattering

Better knowing the precision on the measured value of the Brillouin peak frequencies is essen-tial in order to use it to deduce parameters related to studied materials. Modern methods for evaluating uncertainties are based on the recommendations of the Guide to the expression of uncertainty in measurement. After checking the agreement between the measured 15.7 GHz shift on a Brillouin signal on Poly-(methyl methacrylate) and the expected value, the elementary un-certainty terms are evaluated in two groups, by statistical methods and by other means. We de-scribe the general principle of operation of Brillouin light scattering setup with a high power laser and evaluate the elementary terms of uncertainty, according to international standards en-acted for metrology. The global uncertainty on frequency shift is then calculated and we find +-1.20x10-2 at 2 σ.

physics.ins-det

About Quartz Crystal Resonator Noise: Recent Study

The first step, before investigating physical origins of noise in resonators, is to investigate correlations between external measurement parameters and the resonator noise. Tests and measurements are mainly performed on an advanced phase noise measurement system, recently set up. The resonator noise is examined as a function of the sensitivity to the drive level, the temperature operating point and the tuning capacitor.

physics.ins-det

Applications of the optical fiber to the generation and to the measurement of low-phase-noise microwave signals

The optical fiber used as a microwave delay line exhibits high stability and low noise and makes accessible a long delay (>100 microseconds) in a wide bandwidth (about 40 GHz, limited by the optronic components). Hence, it finds applications as the frequency reference in microwave oscillators and as the reference discriminator for the measurement of phase noise. The fiber is suitable to measure the oscillator stability with a sensitivity of parts in 1E-12. Enhanced sensitivity is obtained with two independent delay lines, after correlating and averaging. Short-term stability of parts in 1E-12 is achieved inserting the delay line in an oscillator. The frequency can be set in steps multiple of the inverse delay, which is in the 10-100 kHz region. This article adds to the available references a considerable amount of engineering and practical knowledge, the understanding of 1/f noise, calibration, the analysis of the cross-spectrum technique to reduce the instrument background, the phase-noise model of the oscillator, and the experimental test of the oscillator model.

physics.optics

Development of a 5 MHz frequency difference pre-multiplier for a short term frequency stability bench of the oscillators

This paper reports the realization of a 5 MHz frequency difference x10 pre-multiplier, developed in the laboratory to replace an obsolete one. The principle we chose is to synthesize a 45 MHz and a 50 MHz from a reference signal and from the signal to be measured, and to subtract one to the other to generate a 5 MHz, whose precision on the measurement is increased by a factor 10. Obtained Allan variance y() at 1 s is 5.10-14 and output spectral density of phase noise floor is about -160 dBc/Hz at 5 MHz.

physics.ins-det

Advanced bridge instrument for the measurement of the phase noise and of the short-term frequency stability of ultra-stable quartz resonators

High-stability quartz oscillators are needed in a number of space applications. A short-term stability of parts in 10^{-14} [Allan deviation σy(τ) ] is sometimes required, for integration time τof approximately 1-10 s. The Centre National d'Etudes Spatiales (CNES) and the FEMTO-ST Institute (formerly LPMO and LCEP), have been collaborating for many years in this domain, aiming at measuring and at understanding the oscillator noise. The highest stability has been observed on 5 MHz and 10 MHz bulk acoustic-wave resonators. Yet this stability is still not sufficient, or the the manufacturing method is not reproducible. Recently, the analysis of a few premium-stability oscillators has demonstrated that the oscillator frequency instability is due to the fluctuation of the resonator natural frequency, rather than to the noise of the sustaining amplifier via the Leeson effect. It is therefore natural to give attention to the measurement of the resonator fluctuations.

physics.ins-det

Spectral density of phase noise inter-laboratory comparison final results

This paper reports main results of the phase noise comparison that has been performed between october 2005 and december 2006, using two oscillators at 5 and 100 MHz and un DRO at 3.5 GHz. The problem is not to compare the performances of several oscillators, but to compare and to make an evaluation of the uncertainties, and of course the resolution and the reproducibility of the measurements. This comparison allow us to determine the ability to get various systems traceable together in order to increase the trust that one can have in phase noise measurements.

physics.ins-det