Searcharxiv⌕ Search

arXiv subjects

Paul F. R. Wilson

Publications and source records attributed to Paul F. R. Wilson.

11 recordsLinked to original sources

Learning Prostate Anatomy at Test Time for Cancer Detection in Micro-Ultrasound

Domain shift across clinical centers using different imaging hardware or acquisition protocols remains a fundamental barrier to deploying deep learning models for prostate cancer (PCa) detection. Existing test-time adaptation (TTA) methods address distribution shift through entropy minimization or augmentation-based self-supervision, correcting for statistical differences in image appearance but ignoring the anatomical structure of the target domain. We propose ANT, a segmentation-guided TTA framework that adapts a pretrained cancer detection encoder to the target domain by solving an auxiliary prostate segmentation task at test time, supervised by pseudo-masks from a frozen pretrained segmentation network. By aligning encoder representations to prostate anatomy in the target domain, ANT corrects domain-specific feature drift while preserving cancer-discriminative structure. The model was trained on 693 patients imaged with an earlier-generation micro-ultrasound scanner in a multi-center clinical trial, and evaluated on 118 patients acquired with a newer-generation system across two centers in another clinical trial. Under a leave-one-center-out protocol with identical evaluation conditions across all methods, ANT improves mean AUC by 2.9% and 3.6% at the biopsy-core and patient levels, respectively, over no adaptation, outperforming TTA baselines. Code is available at: https://github.com/ObedDzik/ant.git.

cs.CV↗

Compass: Prostate Cancer Detection Needs Multi-View Context

Artificial intelligence (AI) analysis of micro-ultrasound ($μ$US) has shown promise for prostate cancer (PCa) detection. However, most existing AI methods focus on the analysis of single $μ$US images in isolation. By contrast, expert $μ$US readers typically assess a full recorded video study, which provides three-dimensional context, to improve PCa detection compared to single-frame analysis. Inspired by this clinical workflow, we propose Compass, a novel AI methodology which models a $μ$US study as a stream of 2D images. Compass jointly integrates rotational sweep videos of the prostate with $μ$US frames acquired at the moment of biopsy, and performs evidence aggregation across the study using a transformer conditioned on the probe's rotational angle. Finally, a decoder head predicts frame-level and study-level risk scores for the patient. The model is trained and evaluated using a multi-center clinical trial dataset of $μ$US studies, including continuous rotational scans of the prostate and videos captured during biopsy acquisition. We compare the proposed method to baseline AI methods from the literature and to risk scores provided by clinical experts. Our framework shows strong performance, highlighting the value of multi-view context for $μ$US PCa detection, and providing a potentially powerful tool to complement human expertise in $μ$US-based PCa diagnosis. Our code is available at: https://github.com/mharmanani/Compass.

cs.CV↗

Learning Where to Look: A Reinforcement Learning Framework for Robust Micro-Ultrasound Prostate Cancer Detection

Micro-ultrasound ($μ$US) is a new, emerging, and promising imaging modality for prostate cancer (PCa) detection, but accurate identification of suspicious tissue remains highly dependent on clinical experience, leading to substantial inter-observer variability. Machine-learning assistance can reduce this variability; however, training reliable deep models is challenging because supervision is sparse and noisy -- typically limited to core-level histopathology outcomes (e.g., cancer grade and its percentage in a biopsy core) without pixel-level lesion annotations and under severe class imbalance. We introduce Prost-RL, which reframes $μ$US PCa detection as a spatially aware, policy-driven inference problem by learning where to look before decoding. Prost-RL integrates a lightweight reinforcement-learning policy into a foundation-model encoder-decoder to generate interpretable spatial attention maps that act as soft prompts for both cancer-likelihood heatmap prediction and image-level classification. We further propose Adaptive Policy Optimization (APO) to stabilize hybrid supervised-RL training and a noise-robust objective combining symmetric cross-entropy with negative-entropy regularization to mitigate weak-label noise and encourage sharp localization. On a cohort of 6,607 biopsy cores from 693 patients across five clinical sites, Prost-RL achieves $79.0\pm3.5$ AUROC with $64.6\pm6.3$% sensitivity at 80% specificity for core-level detection (+2.1 AUROC and +4.5 sensitivity points over the strongest baseline), and $79.3\pm5.8$ AUROC for clinically significant cancer classification. The learned policy highlights biopsy-aligned regions, providing transparent, spatially grounded evidence alongside quantitative risk predictions. Code is available at: https://github.com/DeepRCL/Prost-RL.

cs.CV↗

DualTrack: Sensorless 3D Ultrasound needs Local and Global Context

Three-dimensional ultrasound (US) offers many clinical advantages over conventional 2D imaging, yet its widespread adoption is limited by the cost and complexity of traditional 3D systems. Sensorless 3D US, which uses deep learning to estimate a 3D probe trajectory from a sequence of 2D US images, is a promising alternative. Local features, such as speckle patterns, can help predict frame-to-frame motion, while global features, such as coarse shapes and anatomical structures, can situate the scan relative to anatomy and help predict its general shape. In prior approaches, global features are either ignored or tightly coupled with local feature extraction, restricting the ability to robustly model these two complementary aspects. We propose DualTrack, a novel dual-encoder architecture that leverages decoupled local and global encoders specialized for their respective scales of feature extraction. The local encoder uses dense spatiotemporal convolutions to capture fine-grained features, while the global encoder utilizes an image backbone (e.g., a 2D CNN or foundation model) and temporal attention layers to embed high-level anatomical features and long-range dependencies. A lightweight fusion module then combines these features to estimate the trajectory. Experimental results on a large public benchmark show that DualTrack achieves state-of-the-art accuracy and globally consistent 3D reconstructions, outperforming previous methods and yielding an average reconstruction error below 5 mm.

cs.CV↗

Vision-Language Models Encode Clinical Guidelines for Concept-Based Medical Reasoning

Concept Bottleneck Models (CBMs) are a prominent framework for interpretable AI that map learned visual features to a set of meaningful concepts for task-specific downstream predictions. Their sequential structure enhances transparency by connecting model predictions to the underlying concepts that support them. In medical imaging, where transparency is essential, CBMs offer an appealing foundation for explainable model design. However, discrete concept representations often overlook broader clinical context such as diagnostic guidelines and expert heuristics, reducing reliability in complex cases. We propose MedCBR, a concept-based reasoning framework that integrates clinical guidelines with vision-language and reasoning models. Labeled clinical descriptors are transformed into guideline-conformant text, and a concept-based model is trained with a multitask objective combining multimodal contrastive alignment, concept supervision, and diagnostic classification to jointly ground image features, concepts, and pathology. A reasoning model then converts these predictions into structured clinical narratives that explain the diagnosis, emulating expert reasoning based on established guidelines. MedCBR achieves superior diagnostic and concept-level performance, with AUROCs of 94.2% on ultrasound and 84.0% on mammography. Further experiments on non-medical datasets achieve 86.1% accuracy. Our framework enhances interpretability and forms an end-to-end bridge from medical image analysis to decision-making.

cs.CV↗

GUIDE-US: Grade-Informed Unpaired Distillation of Encoder Knowledge from Histopathology to Micro-UltraSound

Purpose: Non-invasive grading of prostate cancer (PCa) from micro-ultrasound (micro-US) could expedite triage and guide biopsies toward the most aggressive regions, yet current models struggle to infer tissue micro-structure at coarse imaging resolutions. Methods: We introduce an unpaired histopathology knowledge-distillation strategy that trains a micro-US encoder to emulate the embedding distribution of a pretrained histopathology foundation model, conditioned on International Society of Urological Pathology (ISUP) grades. Training requires no patient-level pairing or image registration, and histopathology inputs are not used at inference. Results: Compared to the current state of the art, our approach increases sensitivity to clinically significant PCa (csPCa) at 60% specificity by 3.5% and improves overall sensitivity at 60% specificity by 1.2%. Conclusion: By enabling earlier and more dependable cancer risk stratification solely from imaging, our method advances clinical feasibility. Source code will be publicly released upon publication.

cs.CV↗

ProstNFound+: A Prospective Study using Medical Foundation Models for Prostate Cancer Detection

Purpose: Medical foundation models (FMs) offer a path to build high-performance diagnostic systems. However, their application to prostate cancer (PCa) detection from micro-ultrasound (μUS) remains untested in clinical settings. We present ProstNFound+, an adaptation of FMs for PCa detection from μUS, along with its first prospective validation. Methods: ProstNFound+ incorporates a medical FM, adapter tuning, and a custom prompt encoder that embeds PCa-specific clinical biomarkers. The model generates a cancer heatmap and a risk score for clinically significant PCa. Following training on multi-center retrospective data, the model is prospectively evaluated on data acquired five years later from a new clinical site. Model predictions are benchmarked against standard clinical scoring protocols (PRI-MUS and PI-RADS). Results: ProstNFound+ shows strong generalization to the prospective data, with no performance degradation compared to retrospective evaluation. It aligns closely with clinical scores and produces interpretable heatmaps consistent with biopsy-confirmed lesions. Conclusion: The results highlight its potential for clinical deployment, offering a scalable and interpretable alternative to expert-driven protocols.

eess.IV↗

TRUSWorthy: Toward Clinically Applicable Deep Learning for Confident Detection of Prostate Cancer in Micro-Ultrasound

While deep learning methods have shown great promise in improving the effectiveness of prostate cancer (PCa) diagnosis by detecting suspicious lesions from trans-rectal ultrasound (TRUS), they must overcome multiple simultaneous challenges. There is high heterogeneity in tissue appearance, significant class imbalance in favor of benign examples, and scarcity in the number and quality of ground truth annotations available to train models. Failure to address even a single one of these problems can result in unacceptable clinical outcomes.We propose TRUSWorthy, a carefully designed, tuned, and integrated system for reliable PCa detection. Our pipeline integrates self-supervised learning, multiple-instance learning aggregation using transformers, random-undersampled boosting and ensembling: these address label scarcity, weak labels, class imbalance, and overconfidence, respectively. We train and rigorously evaluate our method using a large, multi-center dataset of micro-ultrasound data. Our method outperforms previous state-of-the-art deep learning methods in terms of accuracy and uncertainty calibration, with AUROC and balanced accuracy scores of 79.9% and 71.5%, respectively. On the top 20% of predictions with the highest confidence, we can achieve a balanced accuracy of up to 91%. The success of TRUSWorthy demonstrates the potential of integrated deep learning solutions to meet clinical needs in a highly challenging deployment setting, and is a significant step towards creating a trustworthy system for computer-assisted PCa diagnosis.

eess.IV↗

Cinepro: Robust Training of Foundation Models for Cancer Detection in Prostate Ultrasound Cineloops

Prostate cancer (PCa) detection using deep learning (DL) models has shown potential for enhancing real-time guidance during biopsies. However, prostate ultrasound images lack pixel-level cancer annotations, introducing label noise. Current approaches often focus on limited regions of interest (ROIs), disregarding anatomical context necessary for accurate diagnosis. Foundation models can overcome this limitation by analyzing entire images to capture global spatial relationships; however, they still encounter challenges stemming from the weak labels associated with coarse pathology annotations in ultrasound data. We introduce Cinepro, a novel framework that strengthens foundation models' ability to localize PCa in ultrasound cineloops. Cinepro adapts robust training by integrating the proportion of cancer tissue reported by pathology in a biopsy core into its loss function to address label noise, providing a more nuanced supervision. Additionally, it leverages temporal data across multiple frames to apply robust augmentations, enhancing the model's ability to learn stable cancer-related features. Cinepro demonstrates superior performance on a multi-center prostate ultrasound dataset, achieving an AUROC of 77.1% and a balanced accuracy of 83.8%, surpassing current benchmarks. These findings underscore Cinepro's promise in advancing foundation models for weakly labeled ultrasound data.

eess.IV↗

Benchmarking Image Transformers for Prostate Cancer Detection from Ultrasound Data

PURPOSE: Deep learning methods for classifying prostate cancer (PCa) in ultrasound images typically employ convolutional networks (CNNs) to detect cancer in small regions of interest (ROI) along a needle trace region. However, this approach suffers from weak labelling, since the ground-truth histopathology labels do not describe the properties of individual ROIs. Recently, multi-scale approaches have sought to mitigate this issue by combining the context awareness of transformers with a CNN feature extractor to detect cancer from multiple ROIs using multiple-instance learning (MIL). In this work, we present a detailed study of several image transformer architectures for both ROI-scale and multi-scale classification, and a comparison of the performance of CNNs and transformers for ultrasound-based prostate cancer classification. We also design a novel multi-objective learning strategy that combines both ROI and core predictions to further mitigate label noise. METHODS: We evaluate 3 image transformers on ROI-scale cancer classification, then use the strongest model to tune a multi-scale classifier with MIL. We train our MIL models using our novel multi-objective learning strategy and compare our results to existing baselines. RESULTS: We find that for both ROI-scale and multi-scale PCa detection, image transformer backbones lag behind their CNN counterparts. This deficit in performance is even more noticeable for larger models. When using multi-objective learning, we can improve performance of MIL, with a 77.9% AUROC, a sensitivity of 75.9%, and a specificity of 66.3%. CONCLUSION: Convolutional networks are better suited for modelling sparse datasets of prostate ultrasounds, producing more robust features than transformers in PCa detection. Multi-scale methods remain the best architecture for this task, with multi-objective learning presenting an effective way to improve performance.

eess.IV↗

Self-Supervised Learning with Limited Labeled Data for Prostate Cancer Detection in High Frequency Ultrasound

Deep learning-based analysis of high-frequency, high-resolution micro-ultrasound data shows great promise for prostate cancer detection. Previous approaches to analysis of ultrasound data largely follow a supervised learning paradigm. Ground truth labels for ultrasound images used for training deep networks often include coarse annotations generated from the histopathological analysis of tissue samples obtained via biopsy. This creates inherent limitations on the availability and quality of labeled data, posing major challenges to the success of supervised learning methods. On the other hand, unlabeled prostate ultrasound data are more abundant. In this work, we successfully apply self-supervised representation learning to micro-ultrasound data. Using ultrasound data from 1028 biopsy cores of 391 subjects obtained in two clinical centres, we demonstrate that feature representations learnt with this method can be used to classify cancer from non-cancer tissue, obtaining an AUROC score of 91% on an independent test set. To the best of our knowledge, this is the first successful end-to-end self-supervised learning approach for prostate cancer detection using ultrasound data. Our method outperforms baseline supervised learning approaches, generalizes well between different data centers, and scale well in performance as more unlabeled data are added, making it a promising approach for future research using large volumes of unlabeled data.