SearcharxivSearch

arXiv subjects

Paul Grimes

Publications and source records attributed to Paul Grimes.

12 recordsLinked to original sources

Black Hole Explorer Mission Development in Japan

The Black Hole Explorer (BHEX) is a next-generation space very-long-baseline interferometry (VLBI) mission concept that will extend existing ground-based millimeter/submillimeter VLBI arrays to space. The Japanese astronomical community has contributed to BHEX mission development through the BHEX Japan Consortium, established in 2023. This paper provides a high-level summary of progress in Japan since 2024, including the establishment of the Black Hole Explorer Working Group (BHEX WG) at the Institute of Space and Astronautical Science (ISAS), JAXA, to conduct the Japanese side of the Pre-Phase~A mission studies. We outline recent advances in key instrument technologies, including concept design studies of a 4.5\,K closed-cycle mechanical cryocooler and prototype development of an ultra-wideband 300\,GHz Superconductor--Insulator--Superconductor (SIS) mixer for BHEX. We also describe ongoing upgrades to Japan's ground infrastructure to support 86\,GHz observations with VERA and simultaneous 86+230\,GHz observations with the Nobeyama 45\,m Telescope.

astro-ph.IM

Dual Band Receiver Design for the Black Hole Explorer (BHEX) Mission

A dual band receiver has been designed for the Black Hole Explorer (BHEX) mission, which is a space Very-Long Baseline Interferometry (VLBI) mission concept, aimed at unveiling the photon ring of black holes. The cryogenic receiver comprises a 228-320 GHz Superconductor-Insulator Superconductor (SIS) receiver, paired with a 76-106.7 GHz HEMT receiver. The details of the design are described in this talk. A novel comb generator, which will be used for delay tracking, has been designed and tested.

astro-ph.IM

Multi-layer anti-reflection coats using ePTFE membrane for mm-wavelength plastic optics

Future millimeter wavelength experiments aim to both increase aperture diameters and broaden bandwidths to increase the sensitivity of the receivers. These changes produce a challenging anti-reflection (AR) design problem for refracting and transmissive optics. The higher frequency plastic optics require consistently thin polymer coats across a wide area, while wider bandwidths require multilayer designs. We present multilayer AR coats for plastic optics of the high frequency BICEP Array receiver (200-300 GHz) utilizing an expanded polytetrafluoroethylene (ePTFE) membrane, layered and compressively heat-bonded to itself. This process allows for a range of densities (from 0.3g/cc to 1g/cc) and thicknesses (>0.05mm) over a wide radius (33cm), opening the parameter space of potential AR coats in interesting directions. The layered ePTFE membrane has been combined with other polymer layers to produce band average reflections between 0.2% and 0.6% on high density polyethylene and a thin high modulus polyethylene window, respectively.

astro-ph.IM

The Black Hole Explorer Cryocooling Instrument

The Black Hole Explorer (BHEX) is a space-based very-long baseline interferometry (VLBI) mission aimed at precision black hole measurements, detecting the photon ring around black holes, exploring spacetime, spin, and mass properties, and validating predictions of General Relativity. These objectives are achieved using cryogenic receivers with quantum-limited sensitivities across a broad frequency range. Dual-band receivers at 80-106 GHz and 240-320 GHz require operating temperatures of 20 K and 4.5 K, respectively. A cryocooling system with two cold stages will be employed: a 20 K stage handling a 125 mW heat load and a 4.5 K stage handling a 10 mW heat load. To design the cryocooling system, the mission leverages existing space industry technology at high Technology Readiness Levels (TRLs), informed by missions such as Planck, JEM/SMILES, Hitomi, and XRISM, and advancements from the ACTDP/JWST program. Integrating the cryocooler with the receivers and broader instrument involves careful consideration of thermal challenges, including linking the cold ends of each cooling stage to minimize heat losses and ensuring adequate passive cooling for the cryocooler warm end heat rejection. Key challenges and trade-offs include sizing the mass and reducing power consumption while meeting the receiver cold temperature requirements, which impact the scientific objectives. This paper addresses efforts to balance the scientific requirements with the limitations of technical cryocooling capabilities within the framework of a small-class (SMEX) space mission, presenting an overview of cooling needs, initial design considerations, a survey of 4 K spaceflight cryocooler developments, and trade-offs.

astro-ph.IM

The Black Hole Explorer: Instrument System Overview

The Black Hole Explorer (BHEX) is a space very-long-baseline interferometry (VLBI) mission concept that is currently under development. BHEX will study supermassive black holes at unprecedented resolution, isolating the signature of the "photon ring" - light that has orbited the black hole before escaping - to probe physics at the edge of the observable universe. It will also measure black hole spins, study the energy extraction and acceleration mechanisms for black hole jets, and characterize the black hole mass distribution. BHEX achieves high angular resolution by joining with ground-based millimeter-wavelength VLBI arrays, extending the size, and therefore improving the angular resolution of the earthbound telescopes. Here we discuss the science instrument concept for BHEX. The science instrument for BHEX is a dual-band, coherent receiver system for 80-320 GHz, coupled to a 3.5-meter antenna. BHEX receiver front end will observe simultaneously with dual polarizations in two bands, one sampling 80-106 GHz and one sampling 240-320 GHz. An ultra-stable quartz oscillator provides the master frequency reference and ensures coherence for tens of seconds. To achieve the required sensitivity, the front end will instantaneously receive 32 GHz of frequency bandwidth, which will be digitized to 64 Gbits/sec of incompressible raw data. These data will be buffered and transmitted to the ground via laser data link, for correlation with data recorded simultaneously at radio telescopes on the ground. We describe the challenges associated with the instrument concept and the solutions that have been incorporated into the baseline design.

astro-ph.IM

Receivers for the Black Hole Explorer (BHEX) Mission

In this paper, we introduce the receiver architecture for the Black Hole Explorer (BHEX) Mission, designed to reveal the photon ring of black holes. The primary instrument is a dual-polarization receiver operating over the 240-320 GHz frequency range, utilizing a Superconductor-Insulator-Superconductor (SIS) mixer. This Double-Side-Band (DSB) receiver has an intermediate frequency (IF) range of 4-12 GHz and operates at a bath temperature of 4.5 K, for optimal performance, which necessitates the integration of a cryocooler. Complementing the primary receiver is a secondary unit covering the 80-106 GHz spectrum, featuring a cryogenic low noise amplifier. This secondary receiver, affixed to the 20 K stage of the cryocooler, serves to augment the SIS receiver performance by employing the Frequency Phase Transfer technique to boost the signal-to-noise ratio at the correlator output. Together, this sophisticated receiver duo is engineered to achieve the quantum-limited sensitivity required to detect the photon ring of black holes, marking a breakthrough in astrophysical observation.

astro-ph.IM

The Black Hole Explorer: Motivation and Vision

We present the Black Hole Explorer (BHEX), a mission that will produce the sharpest images in the history of astronomy by extending submillimeter Very-Long-Baseline Interferometry (VLBI) to space. BHEX will discover and measure the bright and narrow "photon ring" that is predicted to exist in images of black holes, produced from light that has orbited the black hole before escaping. This discovery will expose universal features of a black hole's spacetime that are distinct from the complex astrophysics of the emitting plasma, allowing the first direct measurements of a supermassive black hole's spin. In addition to studying the properties of the nearby supermassive black holes M87* and Sgr A*, BHEX will measure the properties of dozens of additional supermassive black holes, providing crucial insights into the processes that drive their creation and growth. BHEX will also connect these supermassive black holes to their relativistic jets, elucidating the power source for the brightest and most efficient engines in the universe. BHEX will address fundamental open questions in the physics and astrophysics of black holes that cannot be answered without submillimeter space VLBI. The mission is enabled by recent technological breakthroughs, including the development of ultra-high-speed downlink using laser communications, and it leverages billions of dollars of existing ground infrastructure. We present the motivation for BHEX, its science goals and associated requirements, and the pathway to launch within the next decade.

astro-ph.IM

Plastic Laminate Antireflective Coatings for Millimeter-wave Optics in BICEP Array

The BICEP/Keck series of experiments target the Cosmic Microwave Background at degree-scale resolution from the South Pole. Over the next few years, the "Stage-3" BICEP Array (BA) telescope will improve the program's frequency coverage and sensitivity to primordial B-mode polarization by an order of magnitude. The first receiver in the array, BA1, began observing at 30/40 GHz in early 2020. The next two receivers, BA2 and BA3, are currently being assembled and will map the southern sky at frequencies ranging from 95 GHz to 150 GHz. Common to all BA receivers is a refractive, on-axis, cryogenic optical design that focuses microwave radiation onto a focal plane populated with antenna-coupled bolometers. High-performance antireflective coatings up to 760 mm in aperture are needed for each element in the optical chain, and must withstand repeated thermal cycles down to 4 K. Here we present the design and fabrication of the 30/40 GHz anti-reflection coatings for the recently deployed BA1 receiver, then discuss laboratory measurements of their reflectance. We review the lamination method for these single- and dual-layer plastic coatings with indices matched to various polyethylene, nylon and alumina optics. We also describe ongoing efforts to optimize coatings for the next BA cryostats, which may inform technological choices for future Small-Aperture Telescopes of the CMB "Stage 4" experiment.

astro-ph.IM

A Prospective ISRO-CfA Himalayan Sub-millimeter-wave Observatory Initiative

The Smithsonian Astrophysical Observatory (SAO), a member of the Center for Astrophysics | Harvard and Smithsonian, is in discussions with the Space Applications Centre (SAC) of the Indian Space Research Organization (ISRO) and its partners in the newly formed Indian Sub-millimetre-wave Astronomy Alliance (ISAA), to collaborate in the construction of a sub-millimeter-wave astronomy observatory in the high altitude deserts of the Himalayas, initially at the 4500 m Indian Astronomical Observatory, Hanle. Two primary science goals are targeted. One is the mapping of the distribution of neutral atomic carbon, and the carbon monoxide (CO) molecule in higher energy states, in large parts of the Milky Way, and in selected external galaxies. Such studies would advance our understanding of molecular hydrogen present in the interstellar medium, but partly missed by existing observations; and characterize Galaxy-wide molecular cloud excitation conditions, through multi-level CO observations. Stars form in interstellar clouds of molecular gas and dust, and these observations would allow research into the formation and destruction processes of such molecular clouds and the life cycle of galaxies. As the second goal, the observatory would add a new location to the global Event Horizon Telescope (EHT) network, which lacks a station in the Himalayan longitudes. This addition would enhance the quality of the images synthesized by the EHT, support observations in higher sub-millimeter wave bands, sharpening its resolving ability, improve its dynamic imaging capability and add weather resilience to observing campaigns. In the broader context, this collaboration can be a starting point for a wider, mutually beneficial scientific exchange between the Indian and US astronomy communities, including a potential future EHT space component.

astro-ph.IM

First-generation Science Cases for Ground-based Terahertz Telescopes

Ground-based observations at terahertz (THz) frequencies are a newly explorable area of astronomy for the next ten years. We discuss science cases for a first-generation 10-m class THz telescope, focusing on the Greenland Telescope as an example of such a facility. We propose science cases and provide quantitative estimates for each case. The largest advantage of ground-based THz telescopes is their higher angular resolution (~ 4 arcsec for a 10-m dish), as compared to space or airborne THz telescopes. Thus, high-resolution mapping is an important scientific argument. In particular, we can isolate zones of interest for Galactic and extragalactic star-forming regions. The THz windows are suitable for observations of high-excitation CO lines and [N II] 205 um lines, which are scientifically relevant tracers of star formation and stellar feedback. Those lines are the brightest lines in the THz windows, so that they are suitable for the initiation of ground-based THz observations. THz polarization of star-forming regions can also be explored since it traces the dust population contributing to the THz spectral peak. For survey-type observations, we focus on ``sub-THz'' extragalactic surveys, whose uniqueness is to detect galaxies at redshifts z ~ 1--2, where the dust emission per comoving volume is the largest in the history of the Universe. Finally we explore possibilities of flexible time scheduling, which enables us to monitor active galactic nuclei, and to target gamma-ray burst afterglows. For these objects, THz and submillimeter wavelength ranges have not yet been explored.

astro-ph.GA

Prototype finline-coupled TES bolometers for CLOVER

CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 feedhorns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the target NEPs (1.5, 2.5, and 4.5x10^-17 W/rtHz) the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to ensure a 100% operational focal plane. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and present preliminary measurements of the prototype detectors performance.

astro-ph

TES imaging array technology for CLOVER

CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz. The 97-GHz telescope has 160 horns in its focal plane while the 150 and 220-GHz telescopes have 256 horns each. The horns are arranged in a hexagonal array and feed a polarimeter which uses finline-coupled TES bolometers as detectors. To detect the two polarizations the 97-GHz telescope has 320 detectors while the 150 and 220-GHz telescopes have 512 detectors each. To achieve the required NEPs the detectors are cooled to 100 mK for the 97 and 150-GHz polarimeters and 230 mK for the 220-GHz polarimeter. Each detector is fabricated as a single chip to guarantee fully functioning focal planes. The detectors are contained in linear modules made of copper which form split-block waveguides. The detector modules contain 16 or 20 detectors each for compatibility with the hexagonal arrays of horns in the telescopes' focal planes. Each detector module contains a time-division SQUID multiplexer to read out the detectors. Further amplification of the multiplexed signals is provided by SQUID series arrays. The first prototype detectors for CLOVER operate with a bath temperature of 230 mK and are used to validate the detector design as well as the polarimeter technology. We describe the design of the CLOVER detectors, detector blocks, and readout, and give an update on the detector development.

astro-ph