SearcharxivSearch

arXiv subjects

Paul J. Weiser

Publications and source records attributed to Paul J. Weiser.

3 recordsLinked to original sources

HyperFitS -- Hypernetwork Fitting Spectra for metabolic quantification of ${}^1$H MR spectroscopic imaging

Purpose: Proton magnetic resonance spectroscopic imaging ($^1$H MRSI) enables the mapping of whole-brain metabolites concentrations in-vivo. However, a long-standing problem for its clinical applicability is the metabolic quantification, which can require extensive time for spectral fitting. Recently, deep learning methods have been able to provide whole-brain metabolic quantification in only a few seconds. However, neural network implementations often lack configurability and require retraining to change predefined parameter settings. Methods: We introduce HyperFitS, a hypernetwork for spectral fitting for metabolite quantification in whole-brain $^1$H MRSI that flexibly adapts to a broad range of baseline corrections and water suppression factors. Metabolite maps of human subjects acquired at 3T and 7T with isotropic resolutions of 10 mm, 3.4 mm and 2 mm by water-suppressed and water-unsuppressed MRSI were quantified with HyperFitS and compared to conventional LCModel fitting. Results: Metabolic maps show a substantial agreement between the new and gold-standard methods, with significantly faster fitting times by HyperFitS. Quantitative results further highlight the impact of baseline parametrization on metabolic quantification, which can alter results by up to 30%. Conclusion: HyperFitS shows strong agreement with state-of-the-art conventional methods, while reducing processing times from hours to a few seconds. Compared to prior deep learning based spectral fitting methods, HyperFitS enables a wide range of configurability and can adapt to data quality acquired with multiple protocols and field strengths without retraining.

cs.LG

Synthetic Data in MR Spectroscopy: Current Practices, Applications, and Considerations

The use of synthetic data has emerged as an essential tool in Magnetic Resonance Spectroscopy (MRS) research and applications, providing advantages for optimization of acquisition, software validation, deep learning applications, and enhanced reproducibility. Importantly, synthetic data addresses challenges of limited training data availability, particularly for clinical populations, and offers controlled solutions for investigating uncertainties and unexplained variance with in vivo data. This work provides a review and evaluation of current practices in the use and generation of synthetic data within the MRS field. Conducted by the MRS Synthetic Data Working Group under the Code & Data Sharing Committee of the MRS Study Group of the International Society for Magnetic Resonance in Medicine (ISMRM), this manuscript encompasses existing literature, supplemented by collective experience and in-house methodologies.

physics.med-ph

Deep learning water-unsuppressed MRSI at ultra-high field for simultaneous quantitative metabolic, susceptibility and myelin water imaging

Purpose: Magnetic Resonance Spectroscopic Imaging (MRSI) maps endogenous brain metabolism while suppressing the overwhelming water signal. Water-unsuppressed MRSI (wu-MRSI) allows simultaneous imaging of water and metabolites, but large water sidebands cause challenges for metabolic fitting. We developed an end-to-end deep-learning pipeline to overcome these challenges at ultra-high field. Methods:Fast high-resolution wu-MRSI was acquired at 7T with non-cartesian ECCENTRIC sampling and ultra-short echo time. A water and lipid removal network (WALINET+) was developed to remove lipids, water signal, and sidebands. MRSI reconstruction was performed by DeepER and a physics-informed network for metabolite fitting. Water signal was used for absolute metabolite quantification, quantitative susceptibility mapping (QSM), and myelin water fraction imaging (MWF). Results: WALINET+ provided the lowest NRMSE (< 2%) in simulations and in vivo the smallest bias (< 20%) and limits-of-agreement (+-63%) between wu-MRSI and ws-MRSI scans. Several metabolites such as creatine and glutamate showed higher SNR in wu-MRSI. QSM and MWF obtained from wu-MRSI and GRE showed good agreement with 0 ppm/5.5% bias and +-0.05 ppm/ +- 12.75% limits-of-agreement. Conclusion: High-quality metabolic, QSM, and MWF mapping of the human brain can be obtained simultaneously by ECCENTRIC wu-MRSI at 7T with 2 mm isotropic resolution in 12 min. WALINET+ robustly removes water sidebands while preserving metabolite signal, eliminating the need for water suppression and separate water acquisitions.

eess.IV