SearcharxivSearch

arXiv subjects

Paul Tol

Publications and source records attributed to Paul Tol.

3 recordsLinked to original sources

In-flight pixel degradation of the Sentinel 5 Precursor TROPOMI-SWIR HgCdTe detector

The TROPOMI-SWIR HgCdTe detector on the Sentinel-5 Precursor mission has been performing in-orbit measurements of molecular absorption in Earth's atmosphere since its launch in October 2017. In its polar orbit the detector is continuously exposed to potentially harmful energetic particles. Calibration measurements taken during the eclipse are used to inspect the performance of this detector. This paper explores the in-orbit degradation of the HgCdTe detector. After five years, the detector is still performing within specifications, even though pixels are continuously hit by cosmic radiation. The bulk of the impacts have no lasting effects, and most of the damaged pixels (95%) appear to recover on the order of a few days to several months, attributed to a slow spontaneous recovery of defects in the HgCdTe detector material. This is observed at the operational temperature of 140 K. The distribution of the observed recovery times has a mean around nine days with a significant tail towards several months. Pixels that have degraded have a significant probability to degrade again. The location of faulty pixels follows a Poissonian distribution across the detector. No new clusters have appeared, revealing that impacts are dominated by relatively low energetic protons and electrons. Due to the observed spontaneous recovery of pixels, the fraction of pixels meeting all quality requirements in the nominal operations phase has always been over 98.7%. The observed performance of the TROPOMI-SWIR detector in-flight impacts selection criteria of HgCdTe detectors for future space instrumentation.

physics.ins-det

Daily detection and quantification of methane leaks using Sentinel-3: a tiered satellite observation approach with Sentinel-2 and Sentinel-5p

The twin Sentinel-3 satellites have multi-band radiometers which observe in methane-sensitive shortwave infrared bands with daily global coverage and 500 m ground pixel resolution. We investigate the methane observation capability of Sentinel-3 and how its coverage-resolution combination fits between Sentinel-5p and Sentinel-2 within a tiered observation approach for methane leak monitoring. Sentinel-5p measures methane with high precision and daily global coverage, allowing worldwide leak detection but with a coarse spatial resolution of 7 km x 5.5 km. The Sentinel-2 twin satellites have multi-band instruments that can identify source locations of major leaks (> 1 t/h) with their methane observations of 20 m resolution under favorable observational conditions, but these satellites lack daily global coverage We show that methane enhancements can be retrieved from the shortwave infrared band measurements of Sentinel-3. We report the lowest emission detections by Sentinel-3 in the 8-20 t/h range, depending on location and wind conditions. We demonstrate Sentinel-3's capability of identification and monitoring of methane leaks using two case studies. Near Moscow, Sentinel-3 shows that two major short-term leaks, separated by 30 km, occurred simultaneously at a gas pipeline and appear as a single methane plume in Sentinel-5p data. For another Sentinel-5p leak detection near the Hassi Messaoud oil/gas field in Algeria, Sentinel-3 identifies the leaking facility emitting continuously for 6 days, and Sentinel-2 pinpoints the source of the leak at an oil/gas well. Sentinel-2 and Sentinel-3 also show the 6-day leak was followed by a four-month period of burning of the leaking gas, suggesting a gas well blowout to be the cause of the leak.

physics.ao-ph

Effect of atomic transfer on the decay of a Bose-Einstein condensate

We present a model describing the decay of a Bose-Einstein condensate, which assumes the system to remain in thermal equilibrium during the decay. We show that under this assumption transfer of atoms occurs from the condensate to the thermal cloud enhancing the condensate decay rate.

quant-ph