SearcharxivSearch

arXiv subjects

Paul-Eric Pottie

Publications and source records attributed to Paul-Eric Pottie.

At least 19 recordsLinked to original sources

International Optical Clock Comparison Using the European Optical Fiber Network

Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the $10^{-18}$ level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from $7.7\times10^{-18}$ to $6.1\times10^{-17}$. Among the results, the $^{171}$Yb$^+$(E3) clocks at NPL and PTB demonstrated agreement within an uncertainty of $7.7\times10^{-18}$, marking the first international verification of two independently developed optical clocks below one part in $10^{17}$. The operation of the $^{199}$Hg clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with $^{171}$Yb$^+$(E3), $^{171}$Yb, and $^{87}$Sr optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.

physics.atom-ph

Study of laser-beam arrival time synchronization towards sub-picosecond stability level

A precise synchronization between laser pulse and electron beam arrival time is essential for achieving sub-picosecond stability in modern accelerator facilities. In this work, a Low-Level RF system architecture combined with White Rabbit based timing system has been tested through a collaboration between KEK (Japan) and CNRS/IN2P3, IJClab (France). The setup combines a frequency standard generator, an IDROGEN carrier board with an embedded White Rabbit node, and SkyWorks synthesizers of different form factors to distribute phase-locked clock signals over telecommunication fiber. Phase noise power spectral density measurements were performed at several RF sub-harmonics to confirm synchronization performance. These results demonstrate the feasibility of implementing the White Rabbit-IDROGEN synchronization scheme for large-scale accelerators, including applications to laser-based diagnostics.

physics.acc-ph

Coordinated international comparisons between optical clocks connected via fiber and satellite links

Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the second and the use of optical standards for international time scales.

physics.atom-ph

International comparison of optical frequencies with transportable optical lattice clocks

Optical clocks have improved their frequency stability and estimated accuracy by more than two orders of magnitude over the best caesium microwave clocks that realise the SI second. Accordingly, an optical redefinition of the second has been widely discussed, prompting a need for the consistency of optical clocks to be verified worldwide. While satellite frequency links are sufficient to compare microwave clocks, a suitable method for comparing high-performance optical clocks over intercontinental distances is missing. Furthermore, remote comparisons over frequency links face fractional uncertainties of a few $10^{-18}$ due to imprecise knowledge of each clock's relativistic redshift, which stems from uncertainty in the geopotential determined at each distant location. Here, we report a landmark campaign towards the era of optical clocks, where, for the first time, state-of-the-art transportable optical clocks from Japan and Europe are brought together to demonstrate international comparisons that require neither a high-performance frequency link nor information on the geopotential difference between remote sites. Conversely, the reproducibility of the clocks after being transported between countries was sufficient to determine geopotential height offsets at the level of 4 cm. Our campaign paves the way for redefining the SI second and has a significant impact on various applications, including tests of general relativity, geodetic sensing for geosciences, precise navigation, and future timing networks.

physics.atom-ph

Searching for dark matter with an unequal delay interferometer

We propose a new type of experiment that compares the frequency of a clock (an ultra-stable optical cavity in this case) at time $t$ to its own frequency some time $t-T$ earlier, by "storing" the output signal (photons) in a fibre delay line. In ultra-light oscillating dark matter (DM) models, such an experiment is sensitive to coupling of DM to the standard model fields, through oscillations of the cavity and fibre lengths and of the fibre refractive index. Additionally, the sensitivity is significantly enhanced around the mechanical resonances of the cavity. We present experimental result of such an experiment and report no evidence of DM for masses in the [$4.1\times 10^{-11}$, $8.3\times 10^{-10}$]~eV region. In addition, we improve constraints on the involved coupling constants by one order of magnitude in a standard galactic DM model, at the mass corresponding to the resonant frequency of our cavity. Furthermore, in the model of relaxion DM, we improve on existing constraints over the whole DM mass range by about one order of magnitude, and up to six orders of magnitude at resonance.

gr-qc

Universal formalism for data sharing and processing in clock comparison networks

We present a mathematical framework adapted to the comparison of atomic clocks remotely connected by a complex network of optical or microwave links. This framework facilitates the computation of frequency ratios using a generic set of equations that are valid for a wide variety of clock architectures, making the comparison of a large number of clocks practical. This formalism suggests a generic data exchange protocol that can be used in clock comparison collaborations, for which data logging and decision taking are completely local procedures, independently implemented by the participants.

physics.atom-ph

Combining fiber Brillouin amplification with a repeater laser station for fiber-based optical frequency dissemination over 1400 km

We investigate optical frequency dissemination over a 1400 km long fiber link in looped configuration over a pair of underground fibers between Braunschweig and Strasbourg. This fiber link is the first to combine fiber Brillouin amplifiers with a repeater laser station. Phase-coherent operation over more than five days is demonstrated. We analyze the repeatability of the performance over four campaigns and present results of 65 days in total. The weighted mean of the fractional frequency offset of the transferred optical frequency over the complete data set is $(-1.1 \pm 0.4) \times 10^{-20}$. By analyzing the stabilization signals of the two individual fibers, the correlation of the phase noise on the two fibers is shown to be >98%.

physics.ins-det

Novel approaches to dark-matter detection using space-time separated clocks

We discuss the theoretical analysis and interpretation of space-time separated clock experiments in the context of a space-time varying scalar field that is non-universally coupled to the standard model fields. If massive, such a field is a candidate for dark matter and could be detected in laboratory experiments. We show that space-time separated experiments have the potential to probe a fundamentally different parameter space from more common co-located experiments, allowing decorrelation of previously necessarily correlated parameters. Finally, we describe such a space-time separated clock experiment currently running at the Paris Observatory, and present some preliminary results as a proof of principle.

gr-qc

Two-Branch Fiber Link for International Clock Networks

We present our work on realizing two-branch fiber links enabling multiple-partner clock comparisons in Europe. We report in detail on the setup connecting two long haul links, and report for the relative frequency stability and accuracy. We report on a combined uptime of 90% for our dual-branch link during almost one month. We finally discuss the combined uncertainty contribution of the ensemble of the link architecture to a clock comparison. We show that the frequency transfer uncertainty is 2 x 10 --19 .

quant-ph

Hybrid fiber links for accurate optical frequency comparisons

We present the first experimental demonstration over a 43-km-long urban fiber network of a local two-way optical frequency comparison, which does not require any synchronization of the measurements. It was combined with a regular active-noise compensation on another parallel fiber leading to a very reliable and robust frequency transfer. This hybrid scheme enables us to investigate the major limiting factors of the local two-way comparison. We analyze the contribution to the phase noise of the recovered signal by the interferometers at local and remote places. By using the ability of this set up to be injected by a single laser or two independent lasers, we measure the contribution to the long-term instability by the demodulated laser instabilities. We show that a fractional frequency instability level of $1\times10^{-20}$ at 10 000 s can be obtained with this simple setup after 43-km-long propagation in an urban area.

quant-ph

Ultra-stable optical frequency dissemination on a multi-access fibre network

We report the dissemination of an ultrastable optical frequency signal to two distant users simultaneously using a branching network. The ultrastable signal is extracted along a main fibre link; it is optically tracked with a narrow-linewidth laser diode, which light is injected in a secondary link. The propagation noise of both links is actively compensated. We implement this scheme with two links of 50-km fibre spools, the extraction being setup at the mid-point of the main link. We show that the extracted signal at the end of the secondary link exhibits fractional frequency instability of 1.4x10-15 at 1-s measurement time, almost equal to the 1.3x10-15 instability of the main link output end. The long-term instabilities are also very similar, at a level of 3-5x10-20 at 3x104-s integration time. We also show that the setting up of this extraction device, or a simpler one, at the main link input, can test the proper functioning of the noise rejection on this main link. This work is a significant step towards a robust and flexible ultra-stable network for multi-users dissemination.

quant-ph

Cascaded optical fiber link using the Internet network for remote clocks comparison

We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the spans. This device coherently regenerates the optical signal with the heterodyne optical phase locking of a low-noise laser diode. Optical detection of the beat-note signals for the laser lock and the link noise compensation are obtained with stable and low-noise fibered optical interferometer. We show 3.5 days of continuous operation of the noise-compensated 4-span cascaded link leading to fractional frequency instability of 4x10-16 at 1-s measurement time and 1x10-19 at 2000 s. This cascaded link was extended to 1480-km with the same performance. This work is a significant step towards a sustainable wide area ultra-stable optical frequency distribution and comparison network at a very high level of performance.

physics.optics

Frequency and time transfer for metrology and beyond using telecommunication network fibres

The distribution and the comparison of an ultra-stable optical frequency and accurate time using optical fibres have been greatly improved in the last ten years. The frequency stability and accuracy of optical links surpass well-established methods using the global navigation satellite system and geostationary satellites. In this paper, we present a review of the methods and the results obtained. We show that public telecommunication network carrying Internet data can be used to compare and distribute ultra-stable metrological signals over long distances. This novel technique paves the way for the deployment of a national and continental ultra-stable metrological optical network.

physics.optics

Tackling the Limits of Optical Fiber Links

We theoretically and experimentally investigate relevant noise processes arising in optical fiber links, which fundamentally limit their relative stability. We derive the unsuppressed delay noise for three configurations of optical links: two-way method, Sagnac interferometry, and actively compensated link, respectively designed for frequency comparison, rotation sensing, and frequency transfer. We also consider an alternative two-way setup allowing real-time frequency comparison and demonstrate its effectiveness on a proof-of-principle experiment with a 25-km fiber spool. For these three configurations, we analyze the noise arising from uncommon fiber paths in the interferometric ensemble and design optimized interferometers. We demonstrate interferometers with very low temperature sensitivity of respectively -2.2, -0.03 and 1 fs/K. We use one of these optimized interferometers on a long haul compensated fiber link of 540km. We obtain a relative frequency stability of 3E-20 after 10,000 s of integration time.

physics.optics

Two-Way Optical Frequency Comparisons Over 100km Telecommunication Network Fibers

By using two-way frequency transfer, we demonstrate ultra-high resolution comparison of optical frequencies over a telecommunication fiber link of 100 km operating simultaneously digital data transfer. We first propose and experiment a bi-directional scheme using a single fiber. We show that the relative stability at 1 s integration time is 7 10^18 and scales down to 5 10^21. The same level of performance is reached when an optical link is implemented with an active compensation of the fiber noise. We also implement a real-time two-way frequency comparison over a uni-directional telecommunication network using a pair of parallel fibers. The relative frequency stability is 10^15 at 1 s integration time and reaches 2 10^17 at 40 000 s. The fractional uncertainty of the frequency comparisons was evaluated for the best case to 2 10^20. These results open the way to accurate and high resolution frequency comparison of optical clocks over intercontinental fiber networks.

physics.optics

In-line extraction of an ultra-stable frequency signal over an optical fiber link

We demonstrate in-line extraction of an ultra-stable frequency signal over an optical link of 92-km of installed telecommunication fibers, following the proposition of G. Grosche in 2010. We show that the residual frequency noise at the extraction end is noticeably below that at the main link output when the extraction is near the input end, as expected from a simple model of the noise compensation. We obtain relative frequency instabilities, expressed as overlapping Allan deviation, of 8x10-16 at 1 s averaging time and a few 10-19 at 1 day. These results are at the state-of-the-art for a link using urban telecommunication fibers. We also propose an improved scheme which delivers an ultra-stable signal of higher power, in order to feed a secondary link. In-line extraction opens the way to a broad distribution of an ultra-stable frequency reference, enabling a wide range of applications beyond metrology.

physics.optics

A two-dimensional quantum gas in a magnetic trap

We present the first experimental realization of a two-dimensional quantum gas in a purely magnetic trap dressed by a radio frequency field in the presence of gravity. The resulting potential is extremely smooth and very close to harmonic in the two-dimensional plane of confinement. We fully characterize the trap and demonstrate the confinement of a quantum gas to two dimensions. The trap geometry can be modified to a large extent, in particular in a dynamical way. Taking advantage of this possibility, we study the monopole and the quadrupole modes of a two-dimensional Bose gas.

cond-mat.quant-gas

Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network

In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spread spectrum signals using two-way satellite time transfer modems. The results in term of absolute time accuracy (250 ps) and long-term timing stability (20 ps) well outperform the conventional Global Navigation Satellite System or geostationary transfer methods.

physics.optics