Paweł Moskal

Publications and source records attributed to Paweł Moskal.

At least 19 recordsLinked to original sources

Experimental determination of the Dalitz plot for positronium decay using the J-PET detection system

We present the first measurements of the Dalitz plot for ortho-positronium annihilation to three photons. Our measurements, accurate to about 3% statistical and 2-3% systematic uncertainty in angular representation over almost the entire available phase space, were performed using the Jagiellonian Positron Emission Tomograph (J-PET) based on organic scintillator strips. Until now, the Dalitz plot for the three-body positronium decay has been poorly explored. The new measurements presented here are consistent with both the leading-order and next-to-leading order QED predictions for the Dalitz plot.

nucl-ex↗

Roadmap Towards Quantum Entanglement Positron Emission Tomography (QE-PET)

Annihilation photons are quantum entangled in their polarization, a property that is not accessible in state-of-the-art clinical Positron Emission Tomography (PET). This roadmap describes the current status of research in the emerging field of quantum entanglement applications involving these photons for medical diagnosis. It outlines the underlying physics phenomena and the development of detector systems that can serve as a foundation for future Quantum Entanglement PET (QE-PET) scanners. These scanners will be capable of utilizing the entanglement between annihilation photons by measuring their Compton scattering on electrons. This roadmap comprises up-to-date experimental results on the study of quantum entanglement and the decoherence of annihilation photons, alongside the current theoretical understanding of these phenomena. The methods and detector technologies described herein are being developed (i) in order to enhance standard PET imaging by suppressing random coincidences in the reconstruction of annihilation site density distributions, (ii) in order to establish the degree of quantum entanglement as a diagnostic biomarker for tissue pathology and oxygenation, and (iii) in order to elaborate a method for pH imaging. Whether entanglement-based imaging and pH mapping can be successfully translated into clinical practice remains an open question and a subject of exciting ongoing research. This roadmap serves as an invitation to the scientific community to join this burgeoning field.

physics.med-ph↗

A Conjugate Bayesian Framework for Fast 3D Positronium Lifetime Estimation with a Partial System Matrix

Background: Positronium lifetime imaging extends conventional positron emission tomography by using the time interval between positron emission and annihilation as an additional contrast mechanism. Voxel-wise lifetime estimation in fully three-dimensional settings is computationally difficult because the number of feasible detector-time channels grows rapidly, whereas only a small subset is observed in practice. We developed a scalable statistical framework for three-dimensional positronium lifetime estimation based on a time-of-flight-aware partial system matrix restricted to observed detector-time channels, combined with posterior event-to-voxel weighting and a conjugate Gamma--Exponential update for closed-form voxel-wise effective-rate estimation. Results: Restricting the forward model to observed detector-time channels reduced memory and computational requirements while preserving the Poisson data model for retained detected triple coincidences. In simulated data with 4056 voxels, the analytic Bayesian estimator required 2.76 s versus 74.46 s for 10 L-BFGS-B iterations on the same CPU while accurately recovering the effective-rate map. In a triple-coincidence dataset acquired with a J-PET prototype scanner and a NEMA image-quality phantom, a 234 375-voxel effective-rate map was estimated in approximately 3 s from about $3.64\times10^5$ retained events. Conclusions: Restricting the system matrix to observed detector-time channels makes fully three-dimensional positronium lifetime estimation computationally practical for sparse triple-coincidence data. The proposed posterior-weighted conjugate update provides a fast and stable single-component surrogate estimator of voxel-wise effective lifetime for large-scale three-dimensional positronium lifetime imaging.

physics.med-ph↗

First Positronium Lifetime Imaging using $^{52}$Mn and $^{55}$Co with a plastic-based PET scanner

Positronium Lifetime Imaging (PLI) extends positron emission tomography by using the lifetime of positronium atoms as a probe of tissue molecular architecture. In this work, we report the first PLI measurements performed with $^{52}$Mn and $^{55}$Co using the modular J-PET. Four samples were studied in each experiment: two Certified Reference Materials (polycarbonate and fused silica) and two human tissues (cardiac myxoma and adipose). The selection of PLI events was based on the registration of two 511~keV annihilation photons and one prompt gamma in triple coincidence. From the resulting lifetime spectra we extracted the mean ortho-positronium lifetime $τ_{\text{oPs}}$ and the mean positron lifetime $ΔT_{\text{mean}}$ for each sample. The measured values of $τ_{\text{oPs}}$ in polycarbonate using both isotopes matches well with the certified reference values. Furthermore, $^{55}$Co reproduced identical results for fused-silica measurements at their respective uncertainty levels. In contrast, measurements with $^{52}$Mn in fused silica show a minor deviation, which could be caused by the Parafilm spacer. In myxoma and adipose tissue, the reduced $τ_{\text{oPs}}$ values are mainly linked to the long storage history of the samples rather than to the choice of isotope. Comparing peak-to-background ratios and spectral purity, $^{55}$Co provides cleaner PLI data under the same experimental conditions. Although $^{52}$Mn offers a longer half-life and a multi gamma cascade enhancing $β^{+}$ + $γ$ coincidences, but at the expense of higher background. In this study, we demonstrate that the applied selection criteria on the data measured with the modular J-PET can be used for PLI studies even with radionuclides with complex decay patterns.

physics.med-ph↗

First ex-vivo positronium imaging of tissues with modular J-PET scanner using $^{44}$Sc radionuclide

This study presents the first ex-vivo positronium imaging of human tissues using the modular J-PET scanner with the $^{44}$Sc radionuclide. The $^{44}$Sc isotope was produced via the $^{44}$Ca(p, n)$^{44}$Sc nuclear reaction and used to perform positronium imaging of phantom composed of human adipose tissue, cardiac myxoma tissue, thrombi blood clot, and also porous polymer XAD4, and a certified reference material (CRM) made from fused silica. The experiment demonstrates the suitability of $^{44}$Sc as a positron source for positronium imaging. The performance of J-PET for positronium imaging with $^{44}$Sc was validated by proper reconstruction of the mean orthopositronium lifetime for CRM material and XAD-4 polymer. The mean ortho-positronium (oPs) lifetimes determined for adipose tissue, cardiac myxoma tissues and thrombi were consistent with results of previous experiments. The study highlights the potential $^{44}$Sc radionuclide for positronium lifetime imaging (PLI).

physics.med-ph↗

Feasibility study of the positronium lifetime imaging with the Biograph Vision Quadra and J-PET tomographs

Background: After its first ex-vivo and in-vivo demonstration, Positronium Lifetime Imaging (PLI) has received considerable interest as a potential new diagnostic biomarker. High sensitivity Positron Emission Tomography (PET) systems are needed for PLI since it requires simultaneous registration of annihilation photons and prompt gamma. In this simulation-based study, a~feasibility of PLI with the long axial field-of-view Biograph Vision Quadra (Quadra) and the Total Body J-PET scanner was investigated. Methods: The study was performed using the GATE software. Background radiation, present within the Quadra tomograph, was added to the simulation. First, the optimal placement of the energy window for the registration of the prompt gamma was investigated. Next, the organ-wise sensitivity of Quadra was calculated for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. Finally, the sensitivity for the scandium isotope was compared to the sensitivities obtainable with the Total Body J-PET scanner, as well as with the modular J-PET prototype. Results: The PLI sensitivities for the Quadra with the background radiation are estimated to 9.22(3), 10.46(4), 5.91(3), and 15.39(4) cps/kBq for the $^{44}$Sc, $^{68}$Ga, $^{22}$Na and $^{124}$I radioisotopes, respectively. The highest sensitivity was obtained when the energy window for the deexcitation photon is adjacent to the energy window for the annihilation photons. The determined PLI sensitivities with Quadra and the Total Body J-PET are in the order of sensitivities of standard PET imaging with the short axial field-of-view ($\sim$20 cm) PET scanners. Conclusion: The organ-wise PLI sensitivity of Quadra has been computed for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. A sensitivity gain by a factor of 150 was estimated relative to the modular J-PET system previously used for the first in-vivo PLI.

physics.med-ph↗

Endorsing Titanium-Scandium Radionuclide Generator for PET and Positronium Imaging

The development of PET and positronium imaging techniques is strictly related to the availability of suitable radionuclides and robust radiochemistry platforms. Among the emerging candidates, $^{44}$Sc has attracted significant interest due to its favourable physical properties, including a half-life of $\sim$4 hours, a pure $β^{+}$ emission profile, and the additional prompt $γ$-emission that enables advanced triple-photon detection schemes. These characteristics make $^{44}$Sc particularly promising for highresolution imaging and novel quantitative methodologies. However, routine clinical and preclinical implementation requires a practical, sustainable, and cost-efficient production route. In this context, we propose a titanium-scandium radionuclide generator as an optimal solution. This study focuses on optimising the synthesis of the long-lived parent isotope, $^{44}$Ti ($T_{1/2}$ = 59.1 years), from which $^{44}$Sc can be selectively eluted in a chemically pure form when needed. An analysis of various production pathways was conducted, including proton and deuteron reactions on scandium, as well as $α$-particle and lithium-induced reactions on calcium, to determine the most efficient reaction parameters, target design, and expected yield. Furthermore, we identify some existing cyclotron facilities suitable for implementing this technology. Results indicate that efficient $^{44}$Ti production is achievable using proton beams in the 20-30 MeV range under extended irradiation conditions. The proposed generator system would enable routine and decentralised $^{44}$Sc supply. Its integration with the novel J-PET scanner may significantly reduce diagnostic costs and improve access to advanced PET imaging in regions with limited medical imaging infrastructure.

physics.med-ph↗

First positronium imaging using $^{44}$Sc with the J-PET scanner: a case study on the NEMA-Image Quality phantom

Positronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties of biological tissues by imaging the mean lifetime of the positronium atom. Currently, the method is under rapid development in terms of reconstruction and detection systems. Recently, the first in vivo PLI of the human brain was performed using the J-PET scanner utilizing the $^{68}$Ga isotope. However, this isotope has limitations due to its comparatively low prompt gamma yields, which is crucial for positronium lifetime measurement. Among alternative radionuclides, $^{44}$Sc stands out as a promising isotope for PLI, characterized by a clinically suitable half-life (4.04 hours) emitting 1157 keV prompt gamma in 100% cases after the emission of the positron. This study reports the first experimental demonstration of PLI with $^{44}$Sc, carried out on a NEMA-Image Quality (IQ) phantom using the Modular J-PET tomograph-the first plastic scintillators-based PET scanner.

physics.med-ph↗

Positronium Imaging: History, Current Status, and Future Perspectives

Positronium imaging was recently proposed to image the properties of positronium atoms in the patient body. Positronium properties depend on the size of intramolecular voids and oxygen concentration; therefore, they deliver information different and complementary to the anatomic, morphological, and metabolic images. Thus far, the mean ortho-positronium lifetime imaging has been at the center of research interest. The first ex vivo and in vivo positronium lifetime images of humans have been demonstrated with the dedicated J-PET scanner enabling simultaneous registration of annihilation photons and prompt gamma from ${β^{+} γ}$ emitters. Annihilation photons are used to reconstruct the annihilation place and time while prompt gamma is used to reconstruct the time of positronium formation. This review describes recent achievements in the translation of positronium imaging into clinics. The first measurements of positronium lifetime in humans with commercial PET scanners modernized to register triple coincidences are reported. The in vivo observations of differences in ortho-positronium lifetime between tumor and healthy tissues and between different oxygen concentrations are discussed. So far, the positronium lifetime measurements in humans were completed with clinically available ${^{68}\text{Ga}}$, ${^{82}\text{Rb}}$, and ${^{124}\text{I}}$ radionuclides. Status and challenges in developing positronium imaging on a way to a clinically useful procedure are presented and discussed.

physics.med-ph↗

First Positronium Lifetime Imaging with Scandium-44 on a Long Axial Field-of-view PET/CT

Purpose: 44Sc has been successfully produced, synthesized, labeled and first-in-human studies were conducted some years ago. The decay properties of 44Sc, together with being close to a clinical implementation, make it an ideal candidate for in vivo positronium lifetime measurements. In this study, we investigate the count statistics for ortho-positronium (oPs) measurements with 44Sc. Method: A NEMA image quality phantom was filled with 41.7 MBq of 44Sc dissolved in water and scanned on a commercial long-axial field-of-view PET/CT. Three-photon events were identified using a prototype feature of the scanner and dedicated software. The lifetime of oPs was determined in the phantom spheres and in 4x4x4 mm^3 voxels. Results: All measured oPs lifetimes are compatible, within the uncertainties, with the literature values for water. The oPs lifetime is 2.65+-0.50, 1.39+-0.20 and 1.76+-0.18 ns in the three smallest spheres of the phantom and 1.79+-0.57 ns for a single voxel in the central region of the largest sphere. The relative standard deviation in the background regions of the time difference distributions, i.e., for time differences smaller than -2.7 ns, is above 20% - even for voxels inside the phantom spheres. Conclusions: Despite the favorable physical properties of 44Sc, the count statistics of three-photon events remains a challenge. The high prompt-photon energy causes a significant amount of random three-photon coincidences with the given methodology and, therefore, increases the statistical uncertainties on the measured oPs lifetime.

physics.med-ph↗

Realistic Total-Body J-PET Geometry Optimization -- Monte Carlo Study

Total-Body PET is one of the most promising medical diagnostics modalities. The high sensitivity provided by Total-Body technology can be advantageous for novel tomography methods like positronium imaging. Several efforts are ongoing to lower the price of the TB-PET systems. Among the alternatives, the Jagiellonian PET (J-PET) technology, based on plastic scintillator strips, offers a low-cost alternative. The work aimed to compare five Total-Body J-PET geometries as a possible next generation J-PET scanner design. We present comparative studies of performance characteristics of the cost-effective Total-Body PET scanners using J-PET technology. We investigated in silico five Total-Body scanner geometries. Monte Carlo simulations of the XCAT phantom, the 2-meter sensitivity line source and positronium sensitivity phantoms were performed. We compared the sensitivity profiles for 2-gamma and 3-gamma tomography, relative cost of the setups and performed quantitative analysis of the reconstructed images. The analysis of the reconstructed XCAT images reveals the superiority of the seven-ring scanners over the three-ring setups. However, the three-ring scanners would be approximately 2-3 times cheaper. The peak sensitivity values for two-gamma vary from 20 to 34 cps/kBq. The sensitivity curves for the positronium tomography have a similar shape to the two-gamma sensitivity profiles. The peak values are lower compared to the two-gamma cases, from about 20-28 times, with a maximum of 1.66 cps/kBq. The results show the feasibility of multi-organ imaging of all the systems to be considered for the next generation of TB J-PET designs. The relative cost for all the scanners is about 10-4 times lower compared to the cost of the uExplorer. These properties coupled together with J-PET cost-effectiveness, make the J-PET technology an attractive solution for broad application in clinics.

physics.med-ph↗

Positronium Lifetime Imaging with the Biograph Vision Quadra using 124I

Purpose: Measuring the ortho-positronium (oPs) lifetime in human tissue bears the potential of adding clinically relevant information about the tissue microenvironment to conventional positron emission tomography (PET). Through phantom measurements, we investigate the voxel-wise measurement of oPs lifetime using a commercial long-axial field-of-view (LAFOV) PET scanner. Methods: We prepared four samples with mixtures of Amberlite XAD4, a porous polymeric adsorbent, and water and added between 1.12 MBq and 1.44 MBq of $^{124}$I. The samples were scanned in two different setups: once with a couple of centimeters between each sample (15 minutes scan time) and once with all samples taped together (40 minutes scan time). For each scan, we determine the oPs lifetime for the full samples and at the voxel level. The voxel sizes under consideration are $10.0^3$ mm$^3$, $7.1^3$ mm$^3$ and $4.0^3$ mm$^3$. Results: Amberlite XAD4 allows the preparation of samples with distinct oPs lifetime. Using a Bayesian fitting procedure, the oPs lifetimes in the whole samples are $2.52 \pm 0.03$ ns, $2.37\pm 0.03$ ns, $2.27\pm0.04$ ns and $1.82\pm 0.02$ ns, respectively. The voxel-wise oPs lifetime fits showed that even with $4.0^3$ mm$^3$ voxels the samples are clearly distinguishable and a central voxels have good count statistics. However, the situation with the samples close together remains challenging with respect to the spatial distinction of regions with different oPs lifetimes. Conclusion: Our study shows that positronium lifetime imaging on a commercial LAFOV PET/CT should be feasible under clinical conditions using $^{124}$I.

physics.med-ph↗

Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations

Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

hep-ph↗

Positronium imaging with the novel multiphoton PET scanner

In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in them such as, e.g., molecular oxygen, O2; therefore, positronium imaging may provide information about disease progression during the initial stages of molecular alterations. Current PET systems do not allow acquisition of positronium images. This study presents a new method that enables positronium imaging by simultaneous registration of annihilation photons and deexcitation photons from pharmaceuticals labeled with radionuclides. The first positronium imaging of a phantom built from cardiac myxoma and adipose tissue is demonstrated. It is anticipated that positronium imaging will substantially enhance the specificity of PET diagnostics.

physics.med-ph↗

Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography

Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10^{-4}, with an over threefold improvement on the previous measurement.

nucl-ex↗

Silicon Drift Detectors spectroscopic response during the SIDDHARTA-2 Kaonic Helium run at the DAΦNE collider

A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Frascati. The SDDs geometry and electric field configuration, combined with their read-out electronics, make these devices suitable to perform high precision light kaonic atoms spectroscopy measurements in the high background of the DAΦNE collider. This work presents the spectroscopic response of the SDDs system during the kaonic helium first exotic atoms run of SIDDHARTA-2, preliminary to the kaonic deuterium data taking campaign

physics.ins-det↗

Simulating NEMA characteristics of the modular total-body J-PET scanner -- an economic total-body PET from plastic scintillators

The purpose of the presented research is estimation of the performance characteristics of the economic Total-Body Jagiellonian-PET system (TB-J-PET) constructed from plastic scintillators. The characteristics are estimated according to the NEMA NU-2-2018 standards utilizing the GATE package. The simulated detector consists of 24 modules, each built out of 32 plastic scintillator strips (each with cross section of 6 mm times 30 mm and length of 140 cm or 200 cm) arranged in two layers in regular 24-sided polygon circumscribing a circle with the diameter of 78.6 cm. For the TB-J-PET with an axial field-of-view (AFOV) of 200 cm, a spatial resolutions of 3.7 mm (transversal) and 4.9 mm (axial) are achieved. The NECR peak of 630 kcps is expected at 30 kBq/cc activity concentration and the sensitivity at the center amounts to 38 cps/kBq. The SF is estimated to 36.2 %. The values of SF and spatial resolution are comparable to those obtained for the state-of-the-art clinical PET scanners and the first total-body tomographs: uExplorer and PennPET. With respect to the standard PET systems with AFOV in the range from 16 cm to 26 cm, the TB-J-PET is characterized by an increase in NECR approximately by factor of 4 and by the increase of the whole-body sensitivity by factor of 12.6 to 38. The TOF resolution for the TB-J-PET is expected to be at the level of CRT=240 ps (FWHM). For the TB-J-PET with an axial field-of-view (AFOV) of 140 cm, an image quality of the reconstructed images of a NEMA IEC phantom was presented with a contrast recovery coefficient (CRC) and a background variability parameters. The increase of the whole-body sensitivity and NECR estimated for the TB-J-PET with respect to current commercial PET systems makes the TB-J-PET a promising cost-effective solution for the broad clinical applications of total-body PET scanners.

physics.ins-det↗

Development of J-PEM for breast cancer detection and diagnosis using positronium imaging

The purpose of the presented investigations is to design, construct and establish the characteristic performance of the Jagiellonian Positron Emission Mammography(J-PEM), being designed for the detection and diagnosis of breast cancer. Its construction is based on a novel idea of PET tomography based on plastic scintillators and wavelength shifter (WLS) and a new concept of positronium imaging. We have prepared a simulation program based on Monte Carlo methods for optimizing the geometry and material of the J-PEM prototype. Here we present the first results from the simulations and a brief review of the state of art of breast imaging modalities and their characteristics motivating our investigation.

physics.med-ph↗