SearcharxivSearch

arXiv subjects

Pawel Moskal

Publications and source records attributed to Pawel Moskal.

At least 19 recordsLinked to original sources

First measurement of kaonic deuterium X-ray transitions

The study of the strong interaction among hadrons at low energies remains one of the key challenges in fundamental physics because of its non-perturbative nature, which makes theoretical descriptions strongly dependent on experimental input. Although substantial progress has been made for systems involving up and down quarks, theoretical models in the strangeness sector continue to face limitations due to the lack of experimental data. Kaonic atoms provide a powerful tool to study the low-energy strong interaction with strangeness through the energy shifts and widths induced on their lowest atomic levels. In this context, kaonic deuterium X-ray spectroscopy has long represented one of the major open challenges in hadronic-atom physics because of its extremely low X-ray yield. This measurement is particularly important because it gives access to the experimentally inaccessible $K^-n$ interaction at threshold energy. Here, we report the first observation of kaonic deuterium X-ray transitions, performed with the SIDDHARTA-2 experiment at the DA$\Phi$NE collider. We determine the strong-interaction shift and width of the $1s$ level to be $\varepsilon_{1s}=-810.9\pm24.5\,(\mathrm{stat})\pm2.1\,(\mathrm{syst})\,\mathrm{eV}$ and $\Gamma_{1s}=812\pm97\,(\mathrm{stat})\pm33\,(\mathrm{syst})\,\mathrm{eV}$, respectively. This measurement constitutes the most precise experimental determination of the $K^-d$ strong interaction at threshold and allows discrimination among competing theoretical models. Combined with the kaonic hydrogen measurement, this result provides the experimental input required to determine the isospin-dependent $K^-N$ scattering lengths, with implications for the description of the nature of the first predicted hadronic molecular state, the $\Lambda(1405)$, and neutron-rich matter.

nucl-ex

First-in-human quantum entanglement imaging

Annihilation photons are quantum-entangled in polarization, a phenomenon that has not been exploited in medical diagnostics so far. We present the first in vivo imaging of the degree of quantum entanglement of photons originating from positron-electron annihilation within a human subject. This study utilized the Jagiellonian Positron Emission Tomography (J-PET) scanner, constructed from plastic scintillators. In plastics, annihilation photons interact primarily via the Compton effect, which provides simultaneous information regarding the photon interaction position and time, as well as the photon polarization plane. The patient was injected with a DOTA-TATE radiopharmaceutical labeled with the $^{68}$Ga radionuclide. Using the J-PET scanner, we determined the image of the radiopharmaceutical uptake and, simultaneously, the image of the degree of quantum entanglement. The latter was determined from the relative angle between the polarization planes of the annihilation photons. The values of the degree of quantum entanglement extracted for the liver and the spleen are smaller than those predicted for maximally entangled two-photon states, yet larger than expected for separable photons. This demonstration opens new perspectives for the application of quantum entanglement in clinical diagnostics.

physics.med-ph

Kaonic Copper and Fluorine Absolute Yields Measurement with a CZT-based Detection System at DA$Φ$NE

\noindent In this work, new measurements of absolute X-ray yields for several transitions in kaonic copper and, for the first time, in kaonic fluorine are reported. The data were collected by the SIDDHARTA-2 collaboration at the DA$Φ$NE collider using a novel room-temperature Cadmium Zinc Telluride (CZT) detection system. Detection efficiencies were evaluated through a dedicated Geant4 Monte Carlo simulation of the full experimental setup, enabling the extraction of absolute yields per stopped kaon. \noindent The measured yields exhibit a systematic dependence on the principal quantum number, reflecting the interplay between radiative transitions, Auger de-excitation, and strong-interaction-induced nuclear capture. In kaonic fluorine, a suppression of the 4$\to$3 transition yield relative to higher-n transitions is observed, providing evidence for the onset of strong-interaction effects already at the $n=4$ level. From this behaviour, a conservative lower limit on the corresponding strong-interaction width is derived. \noindent These results provide new quantitative constraints for cascade models of exotic atoms and extend experimental access to intermediate atomic levels where strong-interaction effects are not directly observable via level shifts and widths. They also establish CZT-based detection as a powerful and versatile approach for high-resolution X-ray spectroscopy of kaonic atoms in collider environments.

nucl-ex

Quantum Entanglement Degree, Mean Positronium Lifetime, and the $3\gamma$/$2\gamma$ Annihilation-Rate Ratio as Novel PET Biomarkers for Hypoxia -- Concept, Challenges, and Predictions

This manuscript introduces a novel method to assess tissue oxygen concentration via the quantum entanglement (QE) of photons originating from positronium which is produced within the patient's body during positron emission tomography. We also investigate the possibility of assessing hypoxia by simultaneously detecting positronium lifetime and the positronium decay rate ratio. We introduce two distinct quantum sensing approaches. Method 1 utilizes the correlation between oxygen concentration and ortho-positronium (o-Ps) decay rates, relying on the simultaneous measurement of the mean o-Ps lifetime ($\tau_{\mathrm{oPs}}$) and the $3\gamma$-to-$2\gamma$ annihilation rate ratio of o-Ps ($R_{\mathrm{oPs-3\gamma/2\gamma}}$). Method 2 introduces a novel hypothesis: that the degree of QE is sensitive to the relative contribution of annihilation mechanisms (pick-off vs. conversion), which in turn depends on oxygen concentration. We derive a formula for partial pressure of oxygen ($p\mathrm{O}_2$) as a function of $R_{\mathrm{oPs-3\gamma/2\gamma}}$ and $\tau_{\mathrm{oPs}}$ and estimate the measurement accuracy required for these parameters - and for the degree of QE - to sense in-vivo oxygen pressure in the range between hypoxic and physoxic conditions. Theoretical models and quantitative estimates for $R_{\mathrm{oPs-3\gamma/2\gamma}}$, $\tau_{\mathrm{oPs}}$ and for the degree of QE ($C_{\mathrm{QE}}$ ) as a function of $p\mathrm{O}_2$ are provided for water, isopropanol, cyclohexane, isooctane, and adipose tissue. In particular, applying the formulas derived under the working hypothesis that in pick-off process the photons are not entangled, we estimated that for $p\mathrm{O}_2 = 0$, the degree of quantum entanglement $C_{\mathrm{QE}}$ is equal to 0.890 for adipose, 0.886 for isopropanol, 0.867 for water, 0.818 for cyclohexane, and 0.784 for isooctane.

physics.med-ph

Probing Nuclear Structure with Kaonic Atoms through E2 Resonance Mixing

Kaonic atoms provide a unique laboratory to investigate the interplay between atomic, nuclear, and strong-interaction physics. In heavy nuclei, atomic transitions can couple to low-lying collective nuclear excitations via the electric quadrupole interaction. When the energy difference between two kaonic atomic levels approaches that of a nuclear $2^+$ excitation, a resonant configuration mixing may occur, known as the E2 nuclear resonance effect. In this work, we investigate the conditions for E2 resonance in kaonic molybdenum isotopes. We describe the mixing using state-of-the-art Dirac-Fock calculations combined with updated nuclear structure inputs, including recent electric quadrupole transition strength values and excitation energies. We evaluate the sensitivity of the effect to key parameters, assess its observability in future experiments such as the EXKALIBUR program, and discuss its impact on cascade dynamics. Our results demonstrate the potential of kaonic atoms as a probe of nuclear structure, complementary to conventional nuclear spectroscopy.

nucl-ex

CZT Detectors for kaonic atoms spectroscopy

Cadmium zinc telluride (CZT) detectors offer excellent room-temperature energy resolution, making them well suited for X- and $γ$-ray spectroscopy in challenging environments. Within the SIDDHARTA-2 program at the DA$Φ$NE collider, a new CZT-based detection system has been developed to enable precision measurements of kaonic atom transitions in the intermediate mass range. In this work, we report the results of a calibration campaign performed with the collider operating, aimed at assessing the detector performance. A dedicated setup, including an array of quasi-hemispherical CZT sensors and a $^{152}$Eu source, was used to characterize the spectral response. The reconstructed emission lines were fitted with a model accounting for Gaussian response and incomplete charge recollection tails, and the detector linearity was evaluated by comparing the measured peak positions with their nominal energies. The results demonstrate that the CZT detector exhibits excellent linearity and stable operation with the collider on, confirming its suitability for future kaonic-atom spectroscopy at DA$Φ$NE.

physics.ins-det

Extended X-ray energy characterization of SIDDHARTA-2 large-area Silicon Drift Detectors up to 50 keV

The SIDDHARTA-2 experiment at the DA$Φ$NE collider of INFN-LNF performs high precision light kaonic atoms X-ray spectroscopy to investigate the kaon-nucleon(s) strong interaction in the low-energy (O(10 keV)) regime. A large area Silicon Drift Detectors (SDDs) system has been developed to carry out these measurements. The collaboration aims to extend the measurements campaign to higher mass kaonic atoms, which exhibit transition lines at increased X-ray energies. In this context, the spectroscopic response of the SIDDHARTA-2 SDD system was investigated in terms of linearity and energy resolution up to 50 keV. An accuracy of the energy calibration procedure $ΔE/E < 10^{-3}$ was achieved.

physics.ins-det

Time-based Selection of Kaonic Atom X-ray Events with Quasi-Hemispherical CZT Detectors at the DAFNE collider

This work presents the results of a time-based event selection for searching X-ray signals from kaonic atom X-ray transition using a single quasi-hemispherical Cadmium-Zinc-Telluride (CZT) detector at the DA$Φ$NE collider. To mitigate the high background level in the measured X-ray spectrum, a dedicated event selection strategy was developed, exploiting the precise timing correlation between e+e- collisions and detector signals. This approach enabled, for the first time, the observation of two characteristic X-ray transitions from kaonic aluminum atoms using a CZT detector: for the 5-4 transition at 50~keV, 362~$\pm$~41~(stat.)~$\pm$~20~(sys.) signal events over 1698~$\pm$~197~(stat.)~$\pm$~25~(sys.) background events in 5$σ$ were observed, with a resolution of 9.2\%~FWHM; for the 4-3 transition at 106~keV, 295~$\pm$~50~(stat.)~$\pm$~20~(sys.) signal events over 2939~$\pm$~500~(stat.)~$\pm$~16~(sys.) background events in 5$σ$ were measured, with a resolution of 6.6 ~FWHM. A strong background suppression of approximately 95\% of the triggered data was achieved through this time-based selection. The demonstrated timing capability of the CZT detector proved highly effective in isolating time-correlated events within an 80 ns window, setting an important benchmark for the application of these semiconductors in timing-based X-ray spectroscopy. These results highlight the potential of CZT-based detection systems for future precision measurements in high-radiation environments, paving the way for compact, room-temperature X-ray and $γ$-ray spectrometers in fundamental physics and beyond.

physics.ins-det

EXKALIBUR: Towards a Kaonic Atoms Periodic Table to test Fundamental Interactions

Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a unique laboratory to test fundamental interactions at low energies. EXKALIBUR (EXtensive Kaonic Atoms research: from LIthium and Beryllium to URanium) is a program to perform systematic, high-precision X-ray spectroscopy of selected kaonic atoms across the periodic table at the DA$Φ$NE accelerator at the National Laboratory of Frascati (INFN-LNF). Here, we outline its detector-driven strategy: Silicon Drift Detectors for 10-40 keV transitions in light targets (Li, Be, B, O), CdZnTe detectors for 40-300 keV lines in intermediate-$Z$ systems (Mg, Al, Si, S), and a High-Purity Germanium detector for high-$Z$ atoms (Se, Zr, Ta, Mo, W, Pb), complemented by VOXES, a high-resolution crystal spectrometer for sub-eV studies. EXKALIBUR plans to (i) reduce the charged-kaon mass uncertainty below 10 keV, (ii) produce a database of nuclear shifts and widths to constrain multi-nucleon K$^{-}$-nucleus interaction models, and (iii) provide precision data for testing bound-state QED in strong fields. We summarize the planned measurements and expected sensitivities within DA$Φ$NE luminosities.

nucl-ex

Intermediate Mass Kaonic Atoms at DA$Φ$NE

The SIDDHARTA-2 collaboration aims to measure for the first time the shift and width induced on the $1s$ level of kaonic deuterium by the strong interaction. In the preliminary phase to the experiment, a test run using a Helium-4 target was performed to optimize the performance of the full experimental apparatus. This preliminary study highlighted the possibility to measure transition lines coming from intermediate mass kaonic atoms, such as kaonic carbon and kaonic aluminum. In order to measure transitions where strong interaction is manifesting at higher energies, out of the energy range of the SIDDHARTA-2 apparatus, the collaboration is testing a new detector system which exploits a novel compound semiconductor, the Cadmium Zinc Telluride. Tests are now running at DA$Φ$NE to study the performance of this detector, exploring the possibility to build a dedicated setup.

nucl-ex

First Linearity and Stability Characterization for CZT Detection System in a e$^+$e$^-$ Collider Environment

The SIDDHARTA-2 collaboration built a new cadmium-zinc-telluride (CZT, CdZnTe)-based X-ray detection system, used for the first time in the DA$Φ$NE electron-positron collider at INFN-LNF. The aim of this work is to show that these detectors present optimal long- and short-term linearity and stability to perform precise spectroscopic measurements in a collider environment. The spectra used as references for calibration are reported, and the results about the linearity and stability studies are presented. It is also discussed and showed what is the proper function to describe all the effects that alter the Gaussian shape in semiconductors, particularly evident in the CZT case. Good residuals and resolutions were obtained for all the calibrations. In a test run with the source and the collider beam on, it was demonstrated that the calibrations made with beam off are optimal also when the beam is on, and the actual systematics in a physics run were estimated. These promising results show the potentialities of this detector in the high rate environment of a particle collider, and pave the way for the use of CZT detectors in kaonic atoms researches and in accelerators, with applications for particle and nuclear physics.

physics.ins-det

Positronium Physics and Biomedical Applications

Positronium is the simplest bound state, built of an electron and a positron. Studies of positronium in vacuum and its decays in medium tell us about Quantum Electrodynamics, QED, and about the structure of matter and biological processes of living organisms at the nanoscale, respectively. Spectroscopic measurements constrain our understanding of QED bound state theory. Searches for rare decays and measurements of the effect of gravitation on positronium are used to look for new physics phenomena. In biological materials positronium decays are sensitive to the inter- and intra-molecular structure and to the metabolism of living organisms ranging from single cells to human beings. This leads to new ideas of positronium imaging in medicine using the fact that during positron emission tomography (PET) as much as 40% of positron annihilation occurs through the production of positronium atoms inside the patient's body. A new generation of the high sensitivity and multi-photon total-body PET systems opens perspectives for clinical applications of positronium as a biomarker of tissue pathology and the degree of tissue oxidation.

physics.med-ph

Feasibility of the J-PET to monitor range of therapeutic proton beams

Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.

physics.med-ph

Decoherence puzzle in measurements of photons originating from electron-positron annihilation

Entanglement of photons originating from the electron-positron annihilation has not been proven experimentally. Though the independent experiments performed so far unanimously confirm that correlation between the linear polarizations of back-to-back photons from the electron-positron annihilation is consistent with the assumption that these photons are entangled in polarization. Yet, unexpectedly, recent experiments differ as regards the correlation of polarization direction of back-to-back photons after the decoherence induced by scattering of one of these photons on the electron in the scattering material. In one of the experiments, the correlation before and after the decoherence of the photon state is the same and in the other experiment the scattering of one photon leads to a significant decrease in this correlation. Here we discuss this puzzle. The decoherent states were ensured by forcing one of the annihilation photons through prior scattering before the Compton kinematics based measurement of the polarization correlation. A comparison between the experimental setups used for the different measurements and the results obtained are briefly discussed, highlighting the parameters that are important for performing such measurements. Finally, the main features of the J-PET detector are presented with the schemes for performing similar measurements so that the results can be used as conclusive remarks for solving this puzzle. Solving the decoherence puzzle will have crucial consequences for basic studies of entanglement, as well as for the proposed application of polarisation of photons in positron emission tomography. In case if the correlation of polarisation of back-to-back photons from the electron-positron annihilation is the same before and after the scattering of these photons, then it will not be useful for the reduction of the scatter fraction in PET diagnostics.

physics.pop-ph

First Simultaneous K$^-$p $\rightarrow (Σ^0/Λ) \, π^0$ Cross Sections Measurements at 98 MeV/c

We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements ($σ_{K^- p \rightarrow Σ^0 π^0} = 42.8 \pm 1.5 (stat.) ^{+2.4}_{-2.0}(syst.) \ \mathrm{mb}$ and $σ_{K^- p \rightarrow Λπ^0} = 31.0 \pm 0.5 (stat.) ^{+1.2}_{-1.2}(syst.) \ \mathrm{mb}\,$) is the highest yet obtained in the low kaon momentum regime.

nucl-ex

The $η$- and $η'$-nucleus interactions and the search for $η$, $η'$- mesic states

The isoscalar $η$ and $η'$ mesons are special in QCD, being linked both to chiral symmetry and to non-perturbative glue associated with the axial anomaly. The properties of these mesons in medium are sensitive to how these dynamics work in the nuclear environment. In contrast to pionic and kaonic atoms which are mainly bound by the Coulomb interaction with some corrections due to the strong force (Coulomb assisted binding), the $η$ and $η'$ as neutral mesons can only be bound by the strong interaction. Is this interaction strong enough? This topic has inspired a vigorous program of experiments, conducted in close contact with theory, One has to determine the complex $η$, $η'$-nucleus potential. Does the real part $V$ provide a sufficiently deep potential? Is the imaginary part $W$ small enough to allow for narrow states that can more easily be detected experimentally, i.e. $|W| \ll |V|$? The $η'$ effective mass is observed to be suppressed by $\approx -40$ MeV at nuclear matter density. Bound state searches are ongoing. This article gives an overview of the status of knowledge in this field together with an outlook to future experiments.

hep-ph

Investigations on physical and biological range uncertainties in Krakow proton beam therapy centre

Physical and biological range uncertainties limit the clinical potential of Proton Beam Therapy (PBT). In this proceedings, we report on two research projects, which we are conducting in parallel and which both tackle the problem of range uncertainties. One aims at developing software tools and the other at developing detector instrumentation. Regarding the first, we report on our development and pre-clinical application of a GPU-accelerated Monte Carlo (MC) simulation toolkit Fred. Concerning the letter, we report on our investigations of plastic scintillator based PET detectors for particle therapy delivery monitoring. We study the feasibility of Jagiellonian-PET detector technology for proton beam therapy range monitoring by means of MC simulations of the $β^+$ activity induced in a phantom by proton beams and present preliminary results of PET image reconstruction. Using a GPU-accelerated Monte Carlo simulation toolkit Fred and plastic scintillator based PET detectors we aim to improve patient treatment quality with protons.

physics.med-ph

Etaprime and Eta Mesons with Connection to Anomalous Glue

We review the present understanding of etaprime and eta meson physics and these mesons as a probe of gluon dynamics in low-energy QCD. Recent highlights include the production mechanism of eta and etaprime mesons in proton-nucleon collisions from threshold to high-energy, the etaprime effective mass shift in the nuclear medium, searches for possible eta and etaprime bound states in nuclei as well as precision measurements of eta decays as a probe of light-quark masses. We discuss recent experimental data, theoretical interpretation of the different measurements and the open questions and challenges for future investigation.

hep-ph