Searcharxiv⌕ Search

arXiv subjects

Pedro Martín-Mateos

Publications and source records attributed to Pedro Martín-Mateos.

2 recordsLinked to original sources

Dual-comb spectroscopy for the characterization of laboratory flames

Optical spectroscopy, in particular dual-comb (DC) spectroscopy, is a critical, non-invasive tool for combustion diagnostics, offering high precision and calibration-free advantages. However, its implementation remains challenging, especially in the mid-infrared region. This work presents the development of a robust DC spectroscopic system based on electro-optical (EO) frequency comb generators and difference frequency generation (DFG), specifically designed for the characterization of laboratory flames. Operating at a center wavelength of 3427.43 nm, the system utilizes a differential detection strategy to enable precise, calibration-free measurements of unburned methane ($\mathrm{CH_{4}}$) concentrations in a McKenna burner. The experimental results demonstrate an estimated detection limit of 1.1 ppm for a 1 m path length and effectively resolve spatial concentration gradients across the combustion region. Furthermore, the system's high temporal resolution allowed for the identification of dynamic combustion instabilities, including self-sustained pulsations and fuel leakage under fuel-lean conditions. These findings validate the proposed EO architecture as a flexible and highly sensitive tool for advanced flame characterization.

physics.optics↗

Dual-comb photoacoustic spectroscopy with electro-optic generation for the analysis of gaseous samples

In this work we present the design and characterization of a dual comb photoacoustic spectroscopy (DCPAS) set-up for ammonia detection in the near infrared. The system consists of a dual electro-optic (EO) comb generator that generates a multiheterodyne beating signal in the gas sample. The input to the dual EO comb generator is a laser diode tuned to a fixed wavelength within an absorption feature of ammonia (around 1531.6 nm, 6529 cm-1) and we show how the dual comb allows to perform PAS measurements and resolve the absorption features with high spectral resolution. We present results of the ammonia absorption line profile reconstruction with a bandwidth of 1 cm-1 and a resolution of 0.08 cm-1. Moreover, we show that dual comb technique based on electro-optic generation maximally simplifies the optimization of the multiheterodyne signal according the characteristic of the photoacoustic detection module. We present results using a resonant gas cell (pipe shape) and we show how easily the dual comb optical source is adjusted to generate multiherodyne beating tones within the band of resonance of the gas cell.

physics.optics↗