SearcharxivSearch

arXiv subjects

Pei-Qiang Yan

Publications and source records attributed to Pei-Qiang Yan.

2 recordsLinked to original sources

A Continuous Dual-Axis Atomic Interferometric Inertial Sensor

We present an interferometric inertial sensor that utilizes two counter-propagating atomic beams with transverse two-dimensional cooling. By employing three parallel and spatially aligned Raman laser beams for Doppler-sensitive Raman transitions, we successfully generate inertia-sensitive Mach-Zehnder interference fringes with an interrogation length of $2L=54\,\rm{cm}$. The sensor's capability to measure rotation and acceleration simultaneously in dynamic environments is validated through comparative analysis with classical sensors under force oscillation in different directions. Additionally, we conduct experiments on a turntable to calibrate the gyroscope's scaling factor and address nonlinearity. The angular random walk (ARW) and velocity random walk (VRW) of the senor are $3\times10^{-4}\,^\circ/\rm{\sqrt{h}}$ and $107\,\mathrmμg/\rm{\sqrt{Hz}}$, respectively, with the long-term stability reaching $9\times10^{-4}\,\rm{^\circ/h}$ for rotation and $10\,\rm{μg}$ for acceleration at an integration time of 1000s.

physics.atom-ph

Closed-Loop Dual-Atom-Interferometer Inertial Sensor with Continuous Cold Atomic Beams

We demonstrate a closed-loop light-pulse atom interferometer inertial sensor that can realize continuous decoupled measurements of acceleration and rotation rate. The sensor operates with double-loop atom interferometers, which share the same Raman light pulses in a spatially separated Mach-Zehnder configuration and use continuous cold atomic beams propagating in opposite directions from two 2D$^+$ magneto-optical trappings. Acceleration and the rotation rate are decoupled and simultaneously measured by the sum and difference of dual atom-interferometer signals, respectively. The sensitivities of inertial measurements are also increased to be approximately 1.86 times higher than that of a single atom interferometer. The acceleration phase shift is compensated in real time by phase-locking these interferometers via the Raman laser phases from the sum interferometer signal, and the gyroscope perfomance is improved. We achieve long-term stabilities of $6.1 \ μg$ and 840 nrad/s for the acceleration and the rotation rate, respectively, using a short interrogation time of 0.87ms (interference area $A=0.097$ mm$^2$). This work provides a building block for an atomic interferometer based inertial measurement unit for use in field applications that require a high data-rate and high stability.

physics.atom-ph