Searcharxiv⌕ Search

arXiv subjects

Peilong Wang

Publications and source records attributed to Peilong Wang.

22 records · Page 2Linked to original sources

RadOnc-GPT: A Large Language Model for Radiation Oncology

This paper presents RadOnc-GPT, a large language model specialized for radiation oncology through advanced tuning methods. RadOnc-GPT was finetuned on a large dataset of radiation oncology patient records from the Mayo Clinic in Arizona. The model employs instruction tuning on three key tasks - generating radiotherapy treatment regimens, determining optimal radiation modalities, and providing diagnostic descriptions/ICD codes based on patient diagnostic details. Evaluations conducted by comparing RadOnc-GPT outputs to general large language model outputs showed higher ROUGE scores in these three tasks. The study demonstrated the potential of using large language models fine-tuned using domain-specific knowledge like RadOnc-GPT to achieve transformational capabilities in highly specialized healthcare fields such as radiation oncology. However, our model's clinical relevance requires confirmation, and it specializes in only the aforementioned three specific tasks and lacks broader applicability. Furthermore, its evaluation through ROUGE scores might not reflect the true semantic and clinical accuracy - challenges we intend to address in future research.

physics.med-ph↗

1.28 and 5.12 Gbps multi-channel twinax cable receiver ASICs for the ATLAS Inner Tracker Pixel Detector Upgrade

We present two prototypes of a gigabit transceiver ASIC, GBCR1 and GBCR2, both designed in a 65-nm CMOS technology for the ATLAS Inner Tracker Pixel Detector readout upgrade. The first prototype, GBCR1, has four upstream receiver channels and one downstream transmitter channel with pre-emphasis. Each upstream channel receives the data at 5.12 Gbps through a 5 meter AWG34 Twinax cable from an ASIC driver located on the pixel module and restores the signal from the high frequency loss due to the low mass cable. The signal is retimed by a recovered clock before it is sent to the optical transmitter VTRx+. The downstream driver is designed to transmit the 2.56 Gbps signal from lpGBT to the electronics on the pixel module over the same cable. The peak-peak jitter (throughout the paper jitter is always peak-peak unless specified) of the restored signal is 35.4 ps at the output of GBCR1, and 138 ps for the downstream channel at the cable ends. GBCR1 consumes 318 mW and is tested. The second prototype, GBCR2, has seven upstream channels and two downstream channels. Each upstream channel works at 1.28 Gbps to recover the data directly from the RD53B ASIC through a 1 meter custom FLEX cable followed by a 6 meter AWG34 Twinax cable. The equalized signal of each upstream channel is retimed by an input 1.28 GHz phase programmable clock. Compared with the signal at the FLEX input, the additional jitter of the equalized signal is about 80 ps when the retiming logic is o . When the retiming logic is on, the jitter is 50 ps at GBCR2 output, assuming the 1.28 GHz retiming clock is from lpGBT. The downstream is designed to transmit the 160 Mbps signal from lpGBT through the same cable connection to RD53B and the jitter is about 157 ps at the cable ends. GBCR2 consumes about 150 mW when the retiming logic is on. This design was submitted in November 2019.

physics.ins-det↗

Study on the temperature dependence of BGO light yield

The temperature dependence of BGO coupled with photomultiplier tube R5610A-01 was studied in the range of -30°C~30°C. The temperature coefficient of the BGO and R5610A in whole was tested to be -1.82%. And the temperature coefficient of the gain of the R5610A is -0.44% which was tested in the same situation using a blue LED. Thus the temperature coefficient of BGO's light yield can be evaluated as -1.38%.

physics.ins-det↗

Magnetic shield of PMT used in DAMPE electromagnetic calorimeter

The magnetic characteristics of photomultiplier tube R5610A-01 are studied in this paper. The experimental data shows that the gain of R5610A-01 loses about 53% when the magnetic field is 3G along its +X axis. A cylinder of one-layer permalloy strip is able to reduce the effect of 3G magnetic field on the PMT's gain to less than 1%.

physics.ins-det↗