SearcharxivSearch

arXiv subjects

Peng Miao

Publications and source records attributed to Peng Miao.

18 recordsLinked to original sources

Label-Free Intraoperative Imaging of Hemodynamics using Deep Learning

Intraoperative visualization of hemodynamics is crucial for accurate diagnosis and informed surgical decision-making. In neurosurgery, indocyanine green fluorescence imaging (ICG-FI) is the gold standard for assessing blood flow and identifying vascular structures. However, it is limited by time-consuming data acquisition, mandatory waiting periods, potential allergic reactions, and operational complexities. Label-free alternatives, such as laser speckle contrast imaging (LSCI) and white light imaging (WLI), offer real-time vascular assessment but cannot resolve arterial-venous differentiation or blood flow direction determination. To address these challenges, we present a label-free cross-modal generation framework to synthesize mean transition time (MTT) maps from LSCI and WLI. MTT maps encode local hemodynamics, enabling artery-vein differentiation and flow direction inference. Experimental validation in rat brains demonstrates that the proposed method presents clear vasculature delineation, accurate artery-vein differentiation, and reliable blood flow direction decoding, while reducing total imaging time by 95.8% compared to conventional ICG protocols. This approach offers a fast, efficient, and contrast-free solution for continuous intraoperative surgical guidance.

physics.med-ph

A camera system for real-time optical calibration of water-based neutrino telescopes

Calibrating the optical properties within the detection medium of a neutrino telescope is crucial for determining its angular resolution and energy scale. For the next generation of neutrino telescopes planned to be constructed in deep water, such as the TRopIcal DEep-sea Neutrino Telescope (TRIDENT), there are additional challenges due to the dynamic nature and potential non-uniformity of the water medium. This necessitates a real-time optical calibration system distributed throughout the large detector array. This study introduces a custom-designed CMOS camera system equipped with rapid image processing algorithms, providing a real-time optical calibration method for TRIDENT and other similar projects worldwide. In September 2021, the TRIDENT Pathfinder experiment (TRIDENT Explorer, T-REX for short) successfully deployed this camera system in the West Pacific Ocean at a depth of 3420 meters. Within 30 minutes, about 3000 images of the T-REX light source were captured, allowing for the in-situ measurement of seawater attenuation and absorption lengths under three wavelengths. This deep-sea experiment for the first time showcased a technical demonstration of a functioning camera calibration system in a dynamic neutrino telescope site, solidifying a substantial part of the calibration strategies for the future TRIDENT project.

physics.ins-det

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200-1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

hep-ex

The PMT System of the TRIDENT Pathfinder Experiment

Next generation neutrino telescopes are highly anticipated to boost the development of neutrino astronomy. A multi-cubic-kilometer neutrino telescope, TRopIcal DEep-sea Neutrino Telescope (TRIDENT), was proposed to be built in the South China Sea. The detector aims to achieve ~ 0.1 degree angular resolution for track-like events at energy above 100 TeV by using hybrid digital optical modules, opening new opportunities for neutrino astronomy. In order to measure the water optical properties and marine environment of the proposed TRIDENT site, a pathfinder experiment was conducted, in which a 100-meter-long string consisting of three optical modules was deployed at a depth of 3420 m to perform in-situ measurements. The central module emits light by housing LEDs, whereas the other two modules detect light with two independent and complementary systems: the PMT and the camera systems. By counting the number of detected photons and analyzing the photon arrival time distribution, the PMT system can measure the absorption and scattering lengths of sea water, which serve as the basic inputs for designing the neutrino telescope. In this paper, we present the design concept, calibration and performance of the PMT system in the pathfinder experiment.

hep-ex

Demonstrating the Q-Pix front-end using discrete OpAmp and CMOS transistors

Using Commercial Off-The-Shelf (COTS) Operational Amplifiers (OpAmps) and Complementary Metal-Oxide Semiconductor (CMOS) transistors, we present a demonstration of the Q-Pix front-end architecture, a novel readout solution for kiloton-scale Liquid Argon Time Projection Chamber (LArTPC) detectors. The Q-Pix scheme employs a Charge-Integrate/Reset process based on the Least Action principle, enabling pixel-scale self-triggering charge collection and processing, minimizing energy consumption, and maximizing data compression. We examine the architecture's sensitivity, linearity, noise, and other features at the circuit board level and draw comparisons to SPICE simulations. Furthermore, we highlight the resemblance between the Q-Pix front-end and Sigma-Delta modulator, emphasizing that digital data processing techniques for Sigma-Delta can be directly applied to Q-Pix, resulting in enhanced signal-to-noise performance. These insights will inform the development of Q-Pix front-end designs in integrated circuits (IC) and guide data collection and processing for future large-scale LArTPC detectors in neutrino physics and other high-energy physics experiments.

physics.ins-det

A fast tunable driver of light source for the TRIDENT Pathfinder experiment

TRIDENT (The tRopIcal DEep-sea Neutrino Telescope) is a proposed next-generation neutrino telescope to be constructed in the South China Sea. In September 2021, the TRIDENT Pathfinder experiment (TRIDENT EXplorer, T-REX for short) was conducted to evaluate the in-situ optical properties of seawater. The T-REX experiment deployed three digital optical modules at a depth of 3420 meters, including a light emitter module (LEM) and two light receiver modules (LRMs) equipped with photomultiplier tubes (PMTs) and cameras to detect light signals. The LEM emits light in pulsing and steady modes. It features a fast tunable driver to activate light-emitting diodes (LEDs) that emit nanosecond-width light pulses with tunable intensity. The PMTs in the LRM receive single photo-electron (SPE) signals with an average photon number of approximately 0.3 per 1-microsecond time window, which is used to measure the arrival time distribution of the SPE signals. The fast tunable driver can be remotely controlled in real-time by the data acquisition system onboard the research vessel, allowing for convenient adjustments to the driver's parameters and facilitating the acquisition of high-quality experimental data. This paper describes the requirements, design scheme, and test results of the fast tunable driver, highlighting its successful implementation in the T-REX experiment and its potential for future deep-sea experiments.

physics.ins-det

The Light Source of the TRIDENT Pathfinder Experiment

In September 2021, a site scouting mission known as the TRIDENT pathfinder experiment (TRIDENT EXplorer, T-REX for short) was conducted in the South China Sea with the goal of envisaging a next-generation multi-cubic-kilometer neutrino telescope. One of the main tasks is to measure the in-situ optical properties of seawater at depths between $2800~\mathrm{m}$ and $3500~\mathrm{m}$, where the neutrino telescope will be instrumented. To achieve this, we have developed a light emitter module equipped with a clock synchronization system to serve as the light source, which could be operated in pulsing and steady modes. Two light receiver modules housing both photomultiplier tubes (PMTs) and cameras are employed to detect the photons emitted by the light source. This paper presents the instrumentation of the light source in T-REX, including its design, calibration, and performance.

astro-ph.IM

Random matrix description of dynamically backscattered coherent waves propagating in a wide-field-illuminated random medium

The wave propagation in random medium plays a critical role in optics and quantum physics. Multiple scattering of coherent wave in a random medium determines the transport procedure. Brownian motions of the scatterers perturb each propagation trajectory and form dynamic speckle patterns in the backscattered direction. In this study, we applied the random matrix theory (RMT) to investigate the eigenvalue density of the backscattered intensity matrix. We find that the dynamic speckle patterns can be utilized to decouple the singly and multiply backscattered components. The Wishart random matrix of multiple scattering component is well described by the Marcenko-Pastur law, while the single scattering part has low-rank characteristic. We therefore propose a strategy for estimating the first and the second order moments of single and multiple scattering components, respectively, based on the Marcenko-Pastur law and trace analysis. Electric field Monte Carlo simulation and in-vivo experiments demonstrate its potential applications in hidden absorbing object detection and in-vivo blood flow imaging. Our method can be applied to other coherent domain elastic scattering phenomenon for wide-filed propagation of microwave, ultrasound and etc.

physics.optics

Statistical Estimation of Ballistic Signal in Visible Light OCT Based on Random Matrix Description

Visible light optical coherence tomography (vis-OCT) provides a unique tool for imaging the structure and oxygen metabolism in tissues. However, since it works in the spectral domain, vis-OCT still suffers from noises due to the multiple scatterings, e.g. for imaging the human fundus. In this study, we modeled the OCT signals as a hybrid of single and multiple scattering components using Wishart random matrix description, with which the single scattering component thus can be separated out using the low-rank characteristics of the matrix. The model was validated using Monte Carlo simulation. We further demonstrated that this model could significantly improve the imaging performances in human fundus, showing more details of the vascular structure than the current vis-OCT and an increase of signal-to-noise ratio (SNR) up to more than 10dB. The layer structure of the retina can be better revealed with more than 3dB suppression of the blood scattering in OCT signals.

physics.med-ph

Extracting single- and multiple-scattering components in laser speckle contrast imaging of tissue blood flow

Random matrix theory provides new insights into multiple scattering in random media. In a recent study, we demonstrated the statistical separation of single- and multiple-scattering components based on a Wishart random matrix. The first- and second-order moments were estimated through a Wishart random matrix constructed using dynamically-backscattered speckle images. In this study, this new strategy was applied to laser speckle contrast imaging (LSCI) of in-vivo blood flow. The random matrix-based method was adapted and parameterized using electric field Monte Carlo simulations and in-vitro blood flow phantom experiments. The new method was further applied in in-vivo experiments, demonstrating the benefits of separating the single- and multiple-scattering components, and was compared with the traditional temporal LASCA method. More specifically, the new method captures stimulus-induced functional changes in blood flow and tissue perfusion in the superficial and deeper layers. The new method extends the ability of LSCI to image functional and pathological changes.

physics.med-ph

A Se vacancy induced localized Raman mode in two-dimensional MoSe2 grown by CVD

Defects play a significant role in optical properties of semiconducting two-dimensional transition metal dichalcogenides (TMDCs). In ultra-thin MoSe2, a remarkable feature at ~250 cm-1 in Raman spectra is ascribed to be a defect-related mode. Recent attempts failed to explain the origin of this peak, leaving it being a mystery. Here in this work, we demonstrate that this peak is a Se vacancy induced defect mode. Heat effect and hydrogen etching are two main factors to introduce Se vacancies in CVD process of growing MoSe2. A phonon confinement model can well explain the behaviors of intrinsic Raman modes. Density functional theory (DFT) calculation reveals that single Se vacancy (VSe) is responsible for the appearance of Raman peak at ~250 cm-1 and this mode is an A1g-like localized mode which is also confirmed by polarized Raman scattering experiment. The relative strength of this mode can be a characterization of the quality of 2D MoSe2. This work may offer a simple method to tailor chalcogenide vacancies in 2D TMDCs and provide a way to study their vibrational properties.

cond-mat.mtrl-sci

Cosmic test of sTGC detector prototype made in China for ATLAS experiment upgrade

Following the Higgs particle discovery, the Large Hadron Collider complex will be upgraded in several phases allowing the luminosity to increase to $7 \times 10^{34}cm^{-2}s^{-1}$. In order to adapt the ATLAS detector to the higher luminosity environment after the upgrade, part of the ATLAS muon end-cap system, the Small Wheel, will be replaced by the New Small Wheel. The New Small Wheel includes two kinds of detectors: small-strip Thin Gap Chambers and Micromegas. Shandong University, part of the ATLAS collaboration, participates in the construction of the ATLAS New Small Wheel by developing, producing and testing the performance of part of the small-strip Thin Gap Chambers. This paper describes the construction and cosmic-ray testing of small-strip Thin Gap Chambers in Shandong University.

physics.ins-det

An sTGC Prototype Readout System for ATLAS New-Small-Wheel Upgrade

This paper presents a readout system designed for testing the prototype of Small-Strip Thin Gap Chamber (sTGC), which is one of the main detector technologies used for ATLAS New-Small-Wheel Upgrade. This readout system aims at testing one full-size sTGC quadruplet with cosmic muon triggers.

physics.ins-det

The Study of Multi-Layer sTGC Test System for ATLAS Phase-I upgrade

A completely New Small Wheel (NSW) will be constructed for ATLAS Phase-1 upgrade. Small-Strip Thin-Gap-Chamber (sTGC) will devote to the trigger function of NSW. A full-size sTGC quadruplet consists of 4 layers, and will need 4 pad Front-End-Boards and 4 strip Front-End-Boards for sTGC signals readout. The 8 boards should be readout simultaneously at a time. This paper presents the study of multi-layer sTGC test system, a FEB Driver Card (FEBDC) is designed for pFEB and sFEB boards handling. The design and test of FEBDC are described in details.

physics.ins-det

A low power DAQ system with high-speed storage for submersible buoy

Submersible Buoy (SB) is an important apparatus capable of long-term, fixed-point, continuous and multi-directional measurement of acoustic signals and hydrological environment monitoring in the harsh marine environment, providing important information for hydrological environment research, marine organism research and protection. We will describe a real-time data acquisition (DAQ) system with multiple designs to meet low-power consumption and high-speed data transmission.

physics.ins-det

Development of FEB Configuration Test Board for ATLAS NSW Upgrade

The FEB(front end board) configuration test board is developed aiming at meeting the requirement of testing the new generation ASIC(application-specific integrated circuit) chips and its configuration system for ATLAS NSW(New Small Wheel) upgrade, In this paper, some functions are developed in terms of the configurations of the key chips on the FEB, VMM3 and TDS2 using GBT-SCA. Additionally, a flexible communication protocol is designed, verifying the whole data link. It provides technical reference for prototype FEB key chip configuration and data readout, as well as the final system configuration.

physics.ins-det

Scanning Test System Prototype of p/sFEB for the ATLAS Phase-I sTGC Trigger Upgrade

The Pad Front End Board (pFEB) and the Strip Front End Board (sFEB) are developed for the ATLAS Phase-I sTGC Trigger Upgrade. The pFEB is used to to gather and analyze pads trigger, and the sFEB is developed to accept the pad trigger to define the regions-of-interest for strips readout. The performance of p/sFEBs must be confirmed before they are mounted on the sTGC detector. We will present the scanning test system prototype which is designed according to the test requirements of the p/sFEB. In this test system prototype, a simulation signal board is developed to generate different types of signal to the p/sFEB. PC software and FPGA XADC cooperate to achieve the scan test of analog parameter.

eess.SP

Ultra-precision DC source for Superconducting Quantum Computer

The Superconducting Quantum Computing (SQC) is one of the most promising quantum computing techniques. The SQC requires precise control and acquisition to operate the superconducting qubits. The ultra-precision DC source is used to provide a DC bias for the qubit to work at its operation point. With the development of the multi-qubit processor, to use the commercial precise DC source device is impossible for its large volume occupation. We present our ultra-precision DC source which is designed for SQC experiments in this paper. The DC source contains 12 channels in 1U 19~inch crate. The performances of our DC source strongly beat the commercial devices. The output rang is -7~V to +7~V with 20~mA maximum output current. The Vpp of the output noise is 3~uV, and the standard deviation is 0.497~uV. The temperature coefficient is less than 1~ppm/$^{\circ}$C in 14~V range. The primary results show that the total drift of the output within 48h at an A/C room temperature environment is 40~uV which equal to 2.9~ppm/48h. We are still trying to optimize the channel density and long-term drift / stability.

physics.ins-det