SearcharxivSearch

arXiv subjects

Pengcheng Fan

Publications and source records attributed to Pengcheng Fan.

8 recordsLinked to original sources

Impact of Residual Angular Chirp in a Petawatt-class Laser System on Laser-driven Proton Acceleration

Laser-driven proton acceleration has attracted considerable interest owing to its appealing potential in versatile applications including cancer therapy. Proton energies depend critically on the on-target intensities, yet the detrimental impact of focal spot degradation induced by spatiotemporal couplings on the acceleration remains insufficiently elucidated. In this study, we demonstrate that residual angular chirp (AC), stemming from minor misalignments of the grating compressor in a Petawatt-class laser system, acts as a critical bottleneck for proton acceleration. Experimental results reveal that even around 100 microradians of grating misalignment induces substantial focal-spot elongation and a pronounced reduction in peak intensity. By implementing an in situ spectral-blocking diagnostic, we effectively eliminated the residual AC and restored a near-diffraction-limited focus. This optimization led to a significant recovery of the on-target intensity, resulting in a twofold increase in the proton cutoff energy. Our work presents a successful demonstration of diagnosing and eliminating residual AC. This provides a practical reference for generating high-energy proton beams and supporting their diverse applications in a PW-class laser.

physics.plasm-ph

HotLoop Optimization of Petawatt Laser Focal Spot via a Twin-Focus Scheme

Achieving diffraction-limited focusing of high-power laser pulses to generate ultra-high intensities is crucial for developing compact laser-driven particle accelerators and exploring strong-field quantum electrodynamics. However, accurately diagnosing and optimizing the focal spots of petawatt (PW) laser pulses remains a significant challenge. In this work, we present an experimental methodology utilizing a twin-focus scheme to precisely characterize the intensity distribution and wavefront of focused PW femtosecond laser pulses, and employ it to elucidate their power-dependent evolution. Furthermore, we optimized the focal spots at full power via our in-situ wavefront correction method termed ``HotLoop', achieving a Strehl ratio of 0.80 for 1 PW laser pulses. Consequently, the cutoff proton energies in laser proton acceleration experiments were significantly enhanced. The success of this approach underscores the necessity of in-situ high-energy wavefront correction for ultra-high intensity laser-matter interactions.

physics.optics

Baichuan-M1: Pushing the Medical Capability of Large Language Models

The current generation of large language models (LLMs) is typically designed for broad, general-purpose applications, while domain-specific LLMs, especially in vertical fields like medicine, remain relatively scarce. In particular, the development of highly efficient and practical LLMs for the medical domain is challenging due to the complexity of medical knowledge and the limited availability of high-quality data. To bridge this gap, we introduce Baichuan-M1, a series of large language models specifically optimized for medical applications. Unlike traditional approaches that simply continue pretraining on existing models or apply post-training to a general base model, Baichuan-M1 is trained from scratch with a dedicated focus on enhancing medical capabilities. Our model is trained on 20 trillion tokens and incorporates a range of effective training methods that strike a balance between general capabilities and medical expertise. As a result, Baichuan-M1 not only performs strongly across general domains such as mathematics and coding but also excels in specialized medical fields. We have open-sourced Baichuan-M1-14B, a mini version of our model, which can be accessed through the following links.

cs.CL

Efficient real-time spin readout of nitrogen-vacancy centers based on Bayesian estimation

In this work, to improve the spin readout efficiency of the nitrogen vacancy (NV) center, a real-time Bayesian estimation algorithm is proposed, which combines both the prior probability distribution and the fluorescence likelihood function established by the implementation of the NV center dynamics model. The theoretical surpass of the Cramer-Rao lower bound of the readout variance and the improvement of the readout efficiency in the simulation indicate that our approach is an appealing alternative to the conventional photon summation method. The Bayesian real-time estimation readout was experimentally realized by combining a high-performance acquisition and processing hardware, and the Rabi oscillation experiments divulged that the signal-to-noise ratio of our approach was improved by 28.6%. Therefore, it is anticipated that the employed Bayesian estimation readout will effectively present superior sensing capabilities of the NV ensemble, and foster the further development of compact and scalable quantum sensors and consequently novel quantum information processing devices on a monolithic platform.

quant-ph

Boosting Mask R-CNN Performance for Long, Thin Forensic Traces with Pre-Segmentation and IoU Region Merging

Mask R-CNN has recently achieved great success in the field of instance segmentation. However, weaknesses of the algorithm have been repeatedly pointed out as well, especially in the segmentation of long, sparse objects whose orientation is not exclusively horizontal or vertical. We present here an approach that significantly improves the performance of the algorithm by first pre-segmenting the images with a PSPNet algorithm. To further improve its prediction, we have developed our own cost functions and heuristics in the form of training strategies, which can prevent so-called (early) overfitting and achieve a more targeted convergence. Furthermore, due to the high variance of the images, especially for PSPNet, we aimed to develop strategies for a high robustness and generalization, which are also presented here.

cs.CV

Burst Eddy Current Testing with a Diamond Magnetometry

In this work, a burst eddy current testing technique based on the employment of a diamond nitrogen vacancy (NV) center magnetometer with the Hahn echo (HE) sequence is demonstrated. With the confocal experiment apparatus, the HE-based NV magnetometer attained a magnetic sensitivity of $4.3 ~ \mathrm{nT} / \sqrt{\mathrm{Hz}}$ and a volume-normalized sensitivity of $3.6 ~ \mathrm{pT} / \sqrt{\mathrm{Hz} \cdot \mathrm{mm}^{-3}}$, which are 5 times better than the already existing method under the same conditions. Based on the proposed magnetometer configuration, a burst eddy current (BEC) testing prototype achieves a minimum detectable sample smaller than ${300~{\mu} \mathrm{m}}$ and measurement accuracy of $9.85~\mathrm{\mu} \mathrm{m}$., which is employed to image different metallic specimens and detect the layered internal structures. Since our prototype comprises superb high sensitivity, it exhibits various potential applications in the fields of deformation monitoring, security screening, and quality control. Moreover, its biocompatibility and promising nanoscale resolution paves the way for electromagnetic testing in the fields of biomaterials.

physics.app-ph

A pulsed lock-in method for ensemble nitrogen-vacancy center magnetometry

This article proposes a scheme for nitrogen-vacancy (NV) center magnetometry that combines the advantages of lock-in detection and pulse-type scheme. The optimal conditions, optimal sensitivity, and noise-suppression capability of the proposed method are compared with those of the conventional methods from both theoretical and simulation points of view. Through experimental measurements, a four-time improvement in sensitivity and 60-times improvement in minimum resolvable magnetic field (MRMF) was obtained. By using a confocal experiment setup, proposed scheme achieves a sensitivity of 3 nT/Hz1/2 and a MRMF of 100 pT.

physics.app-ph

Diamond Nitrogen-Vacancy Center Magnetometry: Advances and Challenges

Diamond nitrogen-vacancy (NV) center magnetometry has recently received considerable interest from researchers in the fields of applied physics and sensors. The purpose of this review is to analyze the principle, sensitivity, technical development potential, and application prospect of the diamond NV center magnetometry. This review briefly introduces the physical characteristics of NV centers, summarizes basic principles of the NV center magnetometer, analyzes the theoretical sensitivity, and discusses the impact of technical noise on the NV center magnetometer. Furthermore, the most critical technologies that affect the performance of the NV center magnetometer are described: diamond sample preparation, microwave manipulation, fluorescence collection, and laser excitation. The theoretical and technical crucial problems, potential solutions and research technical route are discussed. In addition, this review discusses the influence of technical noise under the conventional technical conditions and the actual sensitivity which is determined by the theoretical sensitivity and the technical noise. It is envisaged that the sensitivity that can be achieved through an optimized design is in the order of 10 fT/Hz^1/2. Finally, the roadmap of applications of the diamond NV center magnetometer are presented.

physics.app-ph