SearcharxivSearch

arXiv subjects

Peter A. Koss

Publications and source records attributed to Peter A. Koss.

3 recordsLinked to original sources

Human Cardiac Measurements with Diamond Magnetometers

We demonstrate direct, non-invasive and non-contact detection of human cardiac magnetic signals using quantum sensors based on nitrogen-vacancy (NV) centers in diamond. Three configurations were employed recording magnetocardiography (MCG) signals in various shielded and unshielded environments. The signals were averaged over a few hundreds up to several thousands of heart beats to detect the MCG traces. The compact room-temperature NV sensors exhibit sensitivities of 6-26 pT/Hz^(1/2) with active sensing volumes below 0.5 mm^3, defining the performance level of the demonstrated MCG measurements. While the present signals are obtained by averaging, this performance already indicates a clear path toward single-shot MCG sensing. To move beyond shielded environments toward practical clinical use, strong noise suppression is required. To this end, we implement NV-based gradiometry and achieve efficient common-mode noise rejection, enabled by the intrinsically small sensing volume of NV sensors. Together, these multi-platform results obtained across diverse magnetic environments provide a solid foundation for translating quantum sensors into human medical diagnostics such as MCG and magnetoencephalography (MEG).

physics.med-ph

Optical Magnetometry based Current Source

We present a current monitoring system based on optical magnetometry, which is able to discriminate true current variations from environmental effects at room temperature. The system consists of a dedicated thermally stable magnetic field confining coil and an array of four optically pumped magnetometers arranged in a two-dimensional gradiometer configuration. These magnetometers monitor magnetic field variations inside the coil, which correlate to the variations of the driving current of the coil. The system uses a digital signal-processing unit to extract and record in real time the magnetic field values measured by the magnetometers, which allows a real time monitoring of the current. The system's coil, which is made out of printed circuit boards, can easily be changed to adapt the current-to-field conversion. Thus, we can expand the applicability of this system to a wide range of currents. By using this system to actively feedback control a current source we stabilized a current of 20 mA on a level better than $5 \times 10^{-9}$.

physics.ins-det

PCB Coil Design Producing a Uniform Confined Magnetic Field

We present a magnetic field confining coil with a sub-$10^{-3}$ field uniformity over a large fraction of the coil. The structure is entirely made out of printed circuit boards (PCBs). The PCB design allows to tailor the path of wires to fit the required geometry. We measure the field uniformity with cesium magnetometers in a field range from 1 to 10 $μ\mathrm{T}$. Our application uses such a coil for an atomic magnetometry-based current controller.

physics.ins-det