Addressing respiratory gating latency for accurate pulse delivery in preclinical electron FLASH irradiation on a clinical linear accelerator

Background: Clinical linear accelerators are an accessible platform for preclinical research on the biological effects of ultra rapid electron irradiation (FLASH). However, they are not inherently designed for the accurate pulse control required for experiments using a small number of relatively high-dose pulses, and available methods for beam control such as respiratory gating can be error prone owing to system latency. Here we experimentally characterize the temporal latency of the respiratory gating system for controlling beam-on and beam-off at the individual linac pulse level. Methods and Materials: We used programmable controller boards and a relay circuit to monitor and control delivery of specific numbers of pulses through the built-in monitor chamber and respiratory gating system of a Varian Trilogy linac. We implemented two methods an adaptive method using only the delivered pulse signal, and a synchronization method additionally using the linac internal pulse-timing signal and characterized their performance for standard and customized pulse sequences. Results: Characterizing the latency parameters permitted choosing optimal timing parameters that maximized the rate of successfully delivering the desired number of pulses using both adaptive and synchronization methods. Conclusions: We demonstrated that accounting for latency and/or using the ability to read the prior information on expected pulse timing can provide high accuracy in delivering specified numbers of pulses. This reliability is critical for accurate dose delivery in preclinical FLASH research of single fraction and especially fractionated dosing regimens. The ability to generate custom pulse sequences enables more detailed exploration of the temporal dependence of biological FLASH effects.

physics.med-ph

Non-invasive Reversible Software-based Electron FLASH Irradiation Configuration of a Linear Accelerator in Clinical Use

Configuring clinical linear accelerators (linacs) for ultra-high dose rate (UHDR) electron experiments typically requires invasive hardware manipulation and/or irreversible manufacturer modifications, limiting broader implementation. We present an independently developed UHDR electron configuration of a clinical TrueBeam linac that allows reversible switching between preclinical UHDR and conventional (CONV) modes using only non-invasive software settings. UHDR mode was achieved via service mode software with RF and beam current settings typical of a photon beam, the photon target and monitor chamber retracted, and a clinically unused low-energy scattering foil inserted. An external AC current transformer (ACCT) for beam monitoring, anatomy-specific collimator, and sample holder were mounted on the accessory tray, with external ion chamber in solid water for exit dose monitoring. Percent depth dose (PDD) was measured for UHDR and CONV beams. Dose-per-pulse (DPP) was varied by adjusting gun voltage and quantified with radiochromic film at different source-to-surface distances (SSD). Beam profiles assessed dose uniformity and usable field size. Dose calibration was established between film, ACCT, and ion chamber, and day-to-day reproducibility was tested. PDD confirmed similar energies for UHDR (12.8MeV) and CONV (11.9MeV) beams with matching profiles through mouse thickness. Maximum DPP exceeded 0.5Gy, reaching ~1.5Gy for collimated in vivo setups and ~0.7Gy at extended SSD for tissue culture. Field flatness and symmetry were maintained, supporting organ-specific irradiations and up to 5cm fields for culture. Calibration showed strong linearity across detectors, and output variation was <4%. We demonstrated accurate, reproducible UHDR delivery on a widely available clinical linac with no invasive hardware manipulation, enabling preclinical FLASH research on a clinical treatment machine.

physics.med-ph

Dosimetric calibration of an anatomically specific ultra-high dose rate electron irradiation platform for preclinical FLASH radiobiology experiments

We characterized the dosimetric properties of a clinical linear accelerator configured to deliver ultra-high dose rate (UHDR) irradiation to mice and cell-culture FLASH radiobiology experiments. UHDR electron beams were controlled by a microcontroller and relay interfaced with the respiratory gating system. We produced beam collimators with indexed stereotactic mouse positioning devices to provide anatomically specific preclinical treatments. Treatment delivery was monitored directly with an ionization chamber, and charge measurements were correlated with radiochromic film at the entry surface of the mice. The setup for conventional (CONV) dose rate irradiation was similar but the source-to-surface distance was longer. Monte Carlo simulations and film dosimetry were used to characterize beam properties and dose distributions. The mean electron beam energies before the flattening filter were 18.8 MeV (UHDR) and 17.7 MeV (CONV), with corresponding values at the mouse surface of 17.2 MeV and 16.2 MeV. The charges measured with an external ion chamber were linearly correlated with the mouse entrance dose. Use of relay gating for pulse control initially led to a delivery failure rate of 20% ($+/-$ 1 pulse); adjustments to account for the linac latency improved this rate to <1/20. Beam field sizes for two anatomically specific mouse collimators (4x4 $cm^2$ for whole-abdomen and 1.5x1.5 $cm^2$ for unilateral lung irradiation) were accurate within <5% and had low radiation leakage (<4%). Normalizing the dose at the center of the mouse (~0.75 cm depth) produced UHDR and CONV doses to the irradiated volumes with >95% agreement. We successfully configured a clinical linear accelerator for increased output and developed a robust preclinical platform for anatomically specific irradiation, with highly accurate and precise temporal and spatial dose delivery, for both CONV and UHDR applications.

physics.med-ph