SearcharxivSearch

arXiv subjects

Peter Harmsma

Publications and source records attributed to Peter Harmsma.

2 recordsLinked to original sources

Semi-analytical modeling of receive transfer function and thermal noise of integrated photonic ultrasound transducers

Ultrasound transducers (UTs) are extensively used in several applications across a multitude of disciplines. A new type of UTs namely integrated photonic ultrasound transducers (IPUTs) possess superior performance due to the presence of optical interrogation systems, avoiding electric crosstalk and thermal electronic noise of the sensor. However, a major component of the IPUT's noise floor is its thermal acoustic noise. Several studies have been proposed to characterize IPUTs' behavior; nevertheless, these are either incomplete (model only the thermal noise) or targeted to characterize specific responses such as static behavior, in which the modeled receive transfer function (RTF) is about two orders lower than the experiments. In this study, we develop semi-analytical models based on time-domain finite element analysis and analytical expressions to characterize the RTF and thermal noise-induced noise equivalent pressure of IPUTs. We validate the models by comparing them with the literature, where we obtain a close match between them.

physics.app-ph

On-chip interrogator based on Fourier Transform spectroscopy

In this paper, the design and the characterization of a novel interrogator based on integrated Fourier transform (FT) spectroscopy is presented. To the best of our knowledge, this is the first integrated FT spectrometer used for the interrogation of photonic sensors. It consists of a planar spatial heterodyne spectrometer, which is implemented using an array of Mach-Zehnder interferometers (MZIs) with different optical path differences. Each MZI employs a 3$\times$3 multi-mode interferometer, allowing the retrieval of the complex Fourier coefficients. We derive a system of non-linear equations whose solution, which is obtained numerically from Newton's method, gives the modulation of the sensor's resonances as a function of time. By taking one of the sensors as a reference, to which no external excitation is applied and its temperature is kept constant, about 92$\%$ of the thermal induced phase drift of the integrated MZIs has been compensated. The minimum modulation amplitude that is obtained experimentally is 400 fm, which is more than two orders of magnitude smaller than the FT spectrometer resolution.

physics.optics