SearcharxivSearch

arXiv subjects

Peter Hopkins

Publications and source records attributed to Peter Hopkins.

4 recordsLinked to original sources

Effect of metal encapsulation on bulk superconducting properties of niobium thin films used in qubits

Niobium metal occupies nearly 100\% of the volume of a typical 2D transmon device. While the aluminum Josephson junction is of utmost importance, maintaining quantum coherence across the entire device means that pair-breaking in Nb leads, capacitive pads, and readout resonators can be a major source of decoherence. The established contributors are surface oxides and hydroxides, as well as absorbed hydrogen and oxygen. Metal encapsulation of freshly grown surfaces with non-oxidizing metals, preferably without breaking the vacuum, is a successful strategy to mitigate these issues. While the positive effects of encapsulation are undeniable, it is important to understand its impact on the macroscopic behavior of niobium films. We present a comprehensive study of the bulk superconducting properties of Nb thin films encapsulated with gold and palladium/gold, and compare them to those of bare Nb films. Magneto-optical imaging, magnetization, resistivity, and London and Campbell penetration depth measurements reveal significant differences in encapsulated samples. Both sputtered, and epitaxial Au-capped films exhibit the highest residual resistivity ratio and superconducting transition temperature, as well as the lowest upper critical field, London penetration depth, and critical current. These results are in good agreement with the microscopic theory of anisotropic normal and superconducting states of Nb. We conclude that pair-breaking in the bulk of niobium films, driven by disorder throughout the film rather than just at the surface, is a significant source of quantum decoherence in transmons. We also conclude that gold capping not only passivates the surface but also affects the properties of the entire film, significantly reducing the scattering rate due to defects likely induced by surface diffusion if the film is not protected immediately after fabrication.

cond-mat.supr-con

Correlating Superconducting Qubit Performance Losses to Sidewall Near-Field Scattering via Terahertz Nanophotonics

Elucidating dielectric losses, structural heterogeneity, and interface imperfections is critical for improving coherence in superconducting qubits. However, most diagnostics rely on destructive electron microscopy or low-throughput millikelvin quantum measurements. Here, we demonstrate noninvasive terahertz (THz) nano-imaging/-spectroscopy of encapsulated niobium transmon qubits, revealing sidewall near-field scattering that correlates with qubit coherence. We further employ a THz hyperspectral line scan to probe dielectric responses and field participation at Al junction interfaces. These findings highlight the promise of THz near-field methods as a high-throughput proxy characterization tool for guiding material selection and optimizing processing protocols to improve qubit and quantum circuit performance.

cond-mat.mes-hall

Identifying Materials-Level Sources of Performance Variation in Superconducting Transmon Qubits

The Superconducting Materials and Systems (SQMS) Center, a DOE National Quantum Information Science Research Center, has conducted a comprehensive and coordinated study using superconducting transmon qubit chips with known performance metrics to identify the underlying materials-level sources of device-to-device performance variation. Following qubit coherence measurements, these qubits of varying base superconducting metals and substrates have been examined with various nondestructive and invasive material characterization techniques at Northwestern University, Ames National Laboratory, and Fermilab as part of a blind study. We find trends in variations of the depth of the etched substrate trench, the thickness of the surface oxide, and the geometry of the sidewall, which when combined, lead to correlations with the T$_1$ lifetime across different devices. In addition, we provide a list of features that varied from device to device, for which the impact on performance requires further studies. Finally, we identify two low-temperature characterization techniques that may potentially serve as proxy tools for qubit measurements. These insights provide materials-oriented solutions to not only reduce performance variations across neighboring devices, but also to engineer and fabricate devices with optimal geometries to achieve performance metrics beyond the state-of-the-art values.

quant-ph

MEMSDuino: An Arduino-Based MEMS Switch Controller

Radio frequency cryogenic switches are a critical enabling technology for quantum information science for both calibration and high throughput testing of samples. Traditionally, solenoid-based switches have been used [1,2], but a transition is being made to MEMS-based (Micro Electro Mechanical Systems) switches due to their lower power dissipation and smaller size, and to minimize the risk that solenoid switches tend to produce current pulses that destroy expensive cryogenic amplifiers and can cause electrostatic damage to devices. These MEMS switches require a 90-volt signal to be applied to the control lines to determine the state of the switches. Switches exist that have built-in CMOS-based (Complimentary Metal Oxide Semiconductor) control electronics to drive the 90 V, but these do not work at the cryogenic temperatures used in quantum information science. There is no currently available room temperature control system with direct control of the switches. The instrument presented here is a 19-inch rack-mount controller for a cryogenic MEMS switch network that allows a human operator to see the state of the switch via a row of clearly marked indicator lights and to change the state manually via buttons on an LED-based indicator board or automatically via Python-based serial port commands to the Arduino, an open source microcontroller platform available from multiple vendors. The design can also be modified to control other switches that require either a large voltage or current to switch.

quant-ph