SearcharxivSearch

arXiv subjects

Peter R. Seevinck

Publications and source records attributed to Peter R. Seevinck.

4 recordsLinked to original sources

SMART tracking: Simultaneous anatomical imaging and real-time passive device tracking for MR-guided interventions

Purpose: This study demonstrates a proof of concept of a method for simultaneous anatomical imaging and real-time (SMART) passive device tracking for MR-guided interventions. Methods: Phase Correlation template matching was combined with a fast undersampled radial multi-echo acquisition using the white marker phenomenon after the first echo. In this way, the first echo provides anatomical contrast, whereas the other echoes provide white marker contrast to allow accurate device localization using fast simulations and template matching. This approach was tested on tracking of five 0.5 mm steel markers in an agarose phantom and on insertion of an MRI-compatible 20 Gauge titanium needle in ex vivo porcine tissue. The locations of the steel markers were quantitatively compared to the marker locations as found on a CT scan of the same phantom. Results: The average pairwise error between the MRI and CT locations was 0.30 mm for tracking of stationary steel spheres and 0.29 mm during motion. Qualitative evaluation of the tracking of needle insertions showed that tracked positions were stable throughout needle insertion and retraction. Conclusions: The proposed SMART tracking method provided accurate passive tracking of devices at high framerates, inclusion of real-time anatomical scanning, and the capability of automatic slice positioning. Furthermore, the method does not require specialized hardware and could therefore be applied to track any rigid metal device that causes appreciable magnetic field distortions.

physics.med-ph

CT synthesis from MR images for orthopedic applications in the lower arm using a conditional generative adversarial network

Purpose: To assess the feasibility of deep learning-based high resolution synthetic CT generation from MRI scans of the lower arm for orthopedic applications. Methods: A conditional Generative Adversarial Network was trained to synthesize CT images from multi-echo MR images. A training set of MRI and CT scans of 9 ex vivo lower arms was acquired and the CT images were registered to the MRI images. Three-fold cross-validation was applied to generate independent results for the entire dataset. The synthetic CT images were quantitatively evaluated with the mean absolute error metric, and Dice similarity and surface to surface distance on cortical bone segmentations. Results: The mean absolute error was 63.5 HU on the overall tissue volume and 144.2 HU on the cortical bone. The mean Dice similarity of the cortical bone segmentations was 0.86. The average surface to surface distance between bone on real and synthetic CT was 0.48 mm. Qualitatively, the synthetic CT images corresponded well with the real CT scans and partially maintained high resolution structures in the trabecular bone. The bone segmentations on synthetic CT images showed some false positives on tendons, but the general shape of the bone was accurately reconstructed. Conclusions: This study demonstrates that high quality synthetic CT can be generated from MRI scans of the lower arm. The good correspondence of the bone segmentations demonstrates that synthetic CT could be competitive with real CT in applications that depend on such segmentations, such as planning of orthopedic surgery and 3D printing.

cs.CV

Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy

To enable magnetic resonance (MR)-only radiotherapy and facilitate modelling of radiation attenuation in humans, synthetic-CT (sCT) images need to be generated. Considering the application of MR-guided radiotherapy and online adaptive replanning, sCT generation should occur within minutes. This work aims at assessing whether an existing deep learning network can rapidly generate sCT images to be used for accurate MR-based dose calculations in the entire pelvis. A study was conducted on data of 91 patients with prostate, rectal and cervical cancer who underwent external beam radiotherapy acquiring both CT and MRI for patients' simulation. Dixon reconstructed water, fat and in-phase images obtained from a conventional dual gradient-recalled echo sequence were used to generate sCT images. A conditional generative adversarial network (cGAN) was trained in a paired fashion on 2D transverse slices of 32 prostate cancer patients. The trained network was tested on the remaining patients to generate sCT images. For 30 patients in the test set, dose recalculations of the clinical plan were performed on sCT images. Dose distributions were evaluated comparing voxel-based dose differences, gamma and dose-volume histogram (DVH) analysis. The sCT generation required 5.6 s and 21 s for a single patient volume on a GPU and CPU, respectively. On average, sCT images resulted in a higher dose to the target of maximum 0.3%. Results suggest that accurate MR-based dose calculation using sCT images generated with a cGAN trained on prostate cancer patients is feasible for the entire pelvis. The sCT generation was sufficiently fast to be integrated into an MR-guided radiotherapy workflow.

physics.med-ph

Deep MR to CT Synthesis using Unpaired Data

MR-only radiotherapy treatment planning requires accurate MR-to-CT synthesis. Current deep learning methods for MR-to-CT synthesis depend on pairwise aligned MR and CT training images of the same patient. However, misalignment between paired images could lead to errors in synthesized CT images. To overcome this, we propose to train a generative adversarial network (GAN) with unpaired MR and CT images. A GAN consisting of two synthesis convolutional neural networks (CNNs) and two discriminator CNNs was trained with cycle consistency to transform 2D brain MR image slices into 2D brain CT image slices and vice versa. Brain MR and CT images of 24 patients were analyzed. A quantitative evaluation showed that the model was able to synthesize CT images that closely approximate reference CT images, and was able to outperform a GAN model trained with paired MR and CT images.

cs.CV