Searcharxiv⌕ Search

arXiv subjects

Philip Schaten

Publications and source records attributed to Philip Schaten.

5 recordsLinked to original sources

BART Online Open-Source Sequence Toolbox for Computational MRI

Purpose In advanced computational MRI techniques, acquisition and reconstruction techniques are jointly designed. For reproducibility, it is therefore important to provide an open implementation of both. At the same time, any use in a clinical environment usually requires a close integration with the MRI scanner. Ensuring long-time reproducibility and maintenance then poses additional challenges. In this work, we aim to provide a fully integrated open-source framework that can meet these demands. Methods A software framework to develop pulse sequences is added to BART, an open-source toolbox for computational MRI. In addition, a vendor-specific driver sequence is developed that can be used to run the sequence on a clinical MRI scanner enabling online adjustment of all relevant sequence parameters. Using the Pulseq format, the exact same sequence can also be reproduced offline using a widely used vendor-neutral open-source standard. Using the Pulseq format, the exact same sequence can also be reproduced offline. As proof-of-concept, quantitative MRI methods for T1 and joint water/fat R2*, B0 mapping using radial FLASH and model-based reconstruction are implemented in the proposed framework. Consistency between online and offline acquisition is validated in phantom and in vivo experiments. Results Quantitative MRI methods highlighting specific challenges of acquisition and reconstruction were successfully implemented in BART. Acquisition parameters and FOV can be adapted online on a clinical MRI system. Quantitative parameter maps from model-based reconstruction agree for online and offline regenerated Pulseq acquisitions. Conclusion This work enables reproducibility of advanced computational MRI methods within a comprehensive end-to-end open-source framework.

physics.med-ph↗

BART Streams: Real-time Reconstruction Using a Modular Framework for Pipeline Processing

Purpose: To create modular solutions for interactive real-time MRI using reconstruction algorithms implemented in BART. Methods: A new protocol for streaming of multidimensional arrays is presented and integrated into BART. The new functionality is demonstrated using examples for cardiac interactive real-time MRI based on radial FLASH, where iterative reconstruction is combined with advanced features such as dynamic coil compression and gradient-delay orrection. We analyze the latency of the reconstruction and measure end-to-end latency of the full imaging process. Results: Reconstruction pipelines with iterative reconstruction and advanced functionality were built in a modular way using scripting. Latency measurements demonstrate latency sufficient for interactive real-time MRI, on the order of 30 ms for BART processing and network transfer time, or 200 ms for end-to-end latency including acquisition, vendor processing, and display. Conclusion: With the new streaming capabilities, real-time reconstruction pipelines can be assembled using BART in a flexible way, enabling rapid prototyping of advanced applications such as interactive real-time MRI.

physics.med-ph↗

Rational Approximation of Golden Angles: Accelerated Reconstructions for Radial MRI

Purpose: To develop a generic radial sampling scheme that combines the advantages of golden ratio sampling with simplicity of equidistant angular patterns. The irrational angle between consecutive spokes in golden ratio based sampling schemes enables a flexible retrospective choice of temporal resolution, while preserving good coverage of k-space for each individual bin. Nevertheless, irrational increments prohibit precomputation of the point-spread function (PSF), can lead to numerical problems, and require more complex processing steps. To avoid these problems, a new sampling scheme based on a rational approximation of golden angles (RAGA) is developed. Methods: The theoretical properties of RAGA sampling are mathematically derived. Sidelobe-to-peak ratios (SPR) are numerically computed and compared to the corresponding golden ratio sampling schemes. The sampling scheme is implemented in the BART toolbox and in a radial gradient-echo sequence. Feasibility is shown for quantitative imaging in a phantom and a cardiac scan of a healthy volunteer. Results: RAGA sampling can accurately approximate golden ratio sampling and has almost identical PSF and SPR. In contrast to golden ratio sampling, each frame can be reconstructed with the same equidistant trajectory using different sampling masks, and the angle of each acquired spoke can be encoded as a small index, which simplifies processing of the acquired data. Conclusion: RAGA sampling provides the advantages of golden ratio sampling while simplifying data processing, rendering it a valuable tool for dynamic and quantitative MRI.

physics.med-ph↗

Model-Based Reconstruction for Joint Estimation of $T_{1}$, $R_{2}^{*}$ and $B_{0}$ Field Maps Using Single-Shot Inversion-Recovery Multi-Echo Radial FLASH

Purpose: To develop a model-based nonlinear reconstruction for simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or fat fraction (FF) mapping using single-shot inversion-recovery (IR) multi-echo radial FLASH. Methods: The proposed model-based reconstruction jointly estimates water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF maps, as well as a set of coil sensitivities directly from $k$-space obtained with a single-shot IR multi-echo radial FLASH sequence using blip gradients across echoes. Joint sparsity constraints are exploited on multiple quantitative maps to improve precision. Validations are performed on numerical and NIST phantoms and with in vivo studies of the human brain and liver at 3 T. Results: Numerical phantom studies demonstrate the effects of fat signals in $T_{1}$ estimation and confirm good quantitative accuracy of the proposed method for all parameter maps. NIST phantom results confirm good quantitative $T_{1}$ and $R_{2}^{*}$ accuracy in comparison to Cartesian references. Apart from good quantitative accuracy and precision for multiple parameter maps, in vivo studies show improved image details utilizing the proposed joint estimation. The proposed method can achieve simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF mapping for brain (0.81 $\times$ 0.81 $\times$ 5 mm$^{3}$) and liver (1.6 $\times$ 1.6 $\times$ 6 mm$^{3}$) imaging within four seconds. Conclusion: The proposed model-based nonlinear reconstruction, in combination with a single-shot IR multi-echo radial FLASH acquisition, enables joint estimation of accurate water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF maps within four seconds. The present work is of potential value for specific clinical applications.

physics.med-ph↗

Free-Breathing Liver Fat, $R_2^*$ and $B_0$ Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-based Reconstruction

This work introduced a stack-of-radial multi-echo asymmetric-echo MRI sequence for free-breathing liver volumetric acquisition. Regularized model-based reconstruction was implemented in Berkeley Advanced Reconstruction Toolbox (BART) to jointly estimate all physical parameter maps (water, fat, R2*, and B0 field inhomogeneity maps) and coil sensitivity maps from self-gated k-space data. Specifically, locally low rank and temporal total variation regularization were employed directly on physical parameter maps. The proposed free-breathing radial technique was tested on a water/fat & iron phantom, a young volunteer, and obesity/diabetes/hepatic steatosis patients. Quantitative fat fraction and R2* accuracy were confirmed by comparing our technique with the reference breath-hold Cartesian scan. The multi-echo radial sampling sequence achieves fast k-space coverage and is robust to motion. Moreover, the proposed motion-resolved model-based reconstruction allows for free-breathing liver fat and R2* quantification in multiple motion states. Overall, our proposed technique offers a convenient tool for non-invasive liver assessment with no breath holding requirement.

physics.med-ph↗