SearcharxivSearch

arXiv subjects

Philippe C Cattin

Publications and source records attributed to Philippe C Cattin.

2 recordsLinked to original sources

Magnet-Free Proton Therapy with 4D Pencil Beam Delivery Optimisation

Objective. Motion management is a critical challenge in proton therapy for mobile tumours. This study aims to develop and evaluate a novel four-dimensional (4D) pencil beam delivery strategy that incorporates respiratory motion into a dynamic treatment plan to improve dose conformity and treatment efficiency. Approach. To assess this 4D pencil beam delivery strategy, a mobile phantom was used. The generated 4D treatment plans were assessed with various scanner configurations, including gantry-free and magnet-free scanner heads. For each setup, the treatment time, dose conformity, and robustness against irregular breathing patterns were quantified. The influence of scanner head design and patient-specific motion irregularities on overall plan quality was evaluated. Main Results. The 4D planning tool generated treatment plans that achieved clinically acceptable dose distributions across all configurations. In magnet-free configurations, static beam operation substantially increased treatment time and reduced dose conformity. In contrast, configurations using a single scanner magnet, without a gantry, maintained acceptable conformity within practical treatment times. Significance. The proposed 4D delivery strategy demonstrates feasibility for treating mobile targets with simplified, gantry-free and magnet-free scanner designs. Further improvements could be achieved by synchronising the patient's breathing with 4D delivery, which may enhance dose accuracy during irregular or interrupted breathing. By reducing system complexity while preserving dosimetric performance, this approach offers a pathway toward more accessible and cost-effective proton beam therapy for motion-affected tumours.

physics.med-ph

Optimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction

Intraoperative ultrasound images are inherently challenging to interpret in liver surgery due to the limited field of view and complex anatomical structures. Bridging the gap between preoperative and intraoperative data is crucial for effective surgical guidance. 3D IntraVascular UltraSound (IVUS) offers a potential solution by enabling the reconstruction of the entire organ, which facilitates registration between preoperative computed tomography (CT) scans and intraoperative IVUS images. In this work, we propose an optimization-based calibration method using a 3D-printed phantom for accurate 3D Intravascular Ultrasound volume reconstruction. Our approach ensures precise alignment of tracked IVUS data with preoperative CT images, improving intraoperative navigation. We validated our method using in vivo swine liver images, achieving a calibration error from 0.88 to 1.80 mm and a registration error from 3.40 to 5.71 mm between the 3D IVUS data and the corresponding CT scan. Our method provides a reliable and accurate means of calibration and volume reconstruction. It can be used to register intraoperative ultrasound images with preoperative CT images in the context of liver surgery, and enhance intraoperative guidance.

cs.CV